Cargando…

Comparison of Diagnostic Value for Chronic Kidney Disease between 640-Slice Computed Tomography Kidney Scan and Conventional Computed Tomography Scan

OBJECTIVE: To explore the diagnostic value for chronic kidney disease (CKD) between 640-slice computed tomography (CT) kidney scan and conventional CT scan. METHODS: A total of 120 CKD patients who received kidney plain scan plus enhanced examination in the CT room of the Medical Imaging Department...

Descripción completa

Detalles Bibliográficos
Autores principales: Zhao, Yusen, Wang, Yaoyi, Xu, Yuanbo, Zhao, Yijie, Qu, Yingwu, Zhang, Hua, Zhang, Zhimin, Hu, Zhenshun, Zhu, Xiaolong, Cui, Shujun, Xie, Jin
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Hindawi 2022
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9433217/
https://www.ncbi.nlm.nih.gov/pubmed/36082054
http://dx.doi.org/10.1155/2022/6587617
_version_ 1784780573859905536
author Zhao, Yusen
Wang, Yaoyi
Xu, Yuanbo
Zhao, Yijie
Qu, Yingwu
Zhang, Hua
Zhang, Zhimin
Hu, Zhenshun
Zhu, Xiaolong
Cui, Shujun
Xie, Jin
author_facet Zhao, Yusen
Wang, Yaoyi
Xu, Yuanbo
Zhao, Yijie
Qu, Yingwu
Zhang, Hua
Zhang, Zhimin
Hu, Zhenshun
Zhu, Xiaolong
Cui, Shujun
Xie, Jin
author_sort Zhao, Yusen
collection PubMed
description OBJECTIVE: To explore the diagnostic value for chronic kidney disease (CKD) between 640-slice computed tomography (CT) kidney scan and conventional CT scan. METHODS: A total of 120 CKD patients who received kidney plain scan plus enhanced examination in the CT room of the Medical Imaging Department of our hospital from June 2019 to September 2019 were selected and randomly divided into the experimental group (n = 60) and the control group (n = 60). Patients in the control group received the conventional CT plain scan and enhanced scan, and for patients in the experimental group, CT plain scan was performed first, the range of 640-slice CT dynamic volume scan was determined, and after bolus injection of contrast agent, dynamic volume scan was performed for scanning in the cortical phase, myeloid phase, and secretory phase. The imaging quality and effective scanning dose were compared between the two modalities, and the relationship between CT values obtained from 640-slice CT scan and conventional CT scan and the renal impairment was analyzed. RESULTS: Compared with the control group, the image quality of 640-slice CT scan conducted in the experimental group was significantly better (P < 0.05); the effective radiation doses of the experimental group and the control group were, respectively, (1.89 ± 0.32) mSv and (3.26 ± 0.47) mSv, indicating that the dose was significantly lower in the experimental group than in the control group (t = 18.664, P < 0.001), and the correlation analysis showed that the relationship between the sum of CT values in the cortical phase of both kidneys and kidney injury in the experimental group was r = 0.835, P < 0.001. CONCLUSION: Both 640-slice CT kidney scan and conventional CT scan can be used in the diagnosis of CKD. 640-slice CT has a lower radiation dose, better image quality, and higher application value.
format Online
Article
Text
id pubmed-9433217
institution National Center for Biotechnology Information
language English
publishDate 2022
publisher Hindawi
record_format MEDLINE/PubMed
spelling pubmed-94332172022-09-07 Comparison of Diagnostic Value for Chronic Kidney Disease between 640-Slice Computed Tomography Kidney Scan and Conventional Computed Tomography Scan Zhao, Yusen Wang, Yaoyi Xu, Yuanbo Zhao, Yijie Qu, Yingwu Zhang, Hua Zhang, Zhimin Hu, Zhenshun Zhu, Xiaolong Cui, Shujun Xie, Jin Contrast Media Mol Imaging Research Article OBJECTIVE: To explore the diagnostic value for chronic kidney disease (CKD) between 640-slice computed tomography (CT) kidney scan and conventional CT scan. METHODS: A total of 120 CKD patients who received kidney plain scan plus enhanced examination in the CT room of the Medical Imaging Department of our hospital from June 2019 to September 2019 were selected and randomly divided into the experimental group (n = 60) and the control group (n = 60). Patients in the control group received the conventional CT plain scan and enhanced scan, and for patients in the experimental group, CT plain scan was performed first, the range of 640-slice CT dynamic volume scan was determined, and after bolus injection of contrast agent, dynamic volume scan was performed for scanning in the cortical phase, myeloid phase, and secretory phase. The imaging quality and effective scanning dose were compared between the two modalities, and the relationship between CT values obtained from 640-slice CT scan and conventional CT scan and the renal impairment was analyzed. RESULTS: Compared with the control group, the image quality of 640-slice CT scan conducted in the experimental group was significantly better (P < 0.05); the effective radiation doses of the experimental group and the control group were, respectively, (1.89 ± 0.32) mSv and (3.26 ± 0.47) mSv, indicating that the dose was significantly lower in the experimental group than in the control group (t = 18.664, P < 0.001), and the correlation analysis showed that the relationship between the sum of CT values in the cortical phase of both kidneys and kidney injury in the experimental group was r = 0.835, P < 0.001. CONCLUSION: Both 640-slice CT kidney scan and conventional CT scan can be used in the diagnosis of CKD. 640-slice CT has a lower radiation dose, better image quality, and higher application value. Hindawi 2022-08-24 /pmc/articles/PMC9433217/ /pubmed/36082054 http://dx.doi.org/10.1155/2022/6587617 Text en Copyright © 2022 Yusen Zhao et al. https://creativecommons.org/licenses/by/4.0/This is an open access article distributed under the Creative Commons Attribution License, which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited.
spellingShingle Research Article
Zhao, Yusen
Wang, Yaoyi
Xu, Yuanbo
Zhao, Yijie
Qu, Yingwu
Zhang, Hua
Zhang, Zhimin
Hu, Zhenshun
Zhu, Xiaolong
Cui, Shujun
Xie, Jin
Comparison of Diagnostic Value for Chronic Kidney Disease between 640-Slice Computed Tomography Kidney Scan and Conventional Computed Tomography Scan
title Comparison of Diagnostic Value for Chronic Kidney Disease between 640-Slice Computed Tomography Kidney Scan and Conventional Computed Tomography Scan
title_full Comparison of Diagnostic Value for Chronic Kidney Disease between 640-Slice Computed Tomography Kidney Scan and Conventional Computed Tomography Scan
title_fullStr Comparison of Diagnostic Value for Chronic Kidney Disease between 640-Slice Computed Tomography Kidney Scan and Conventional Computed Tomography Scan
title_full_unstemmed Comparison of Diagnostic Value for Chronic Kidney Disease between 640-Slice Computed Tomography Kidney Scan and Conventional Computed Tomography Scan
title_short Comparison of Diagnostic Value for Chronic Kidney Disease between 640-Slice Computed Tomography Kidney Scan and Conventional Computed Tomography Scan
title_sort comparison of diagnostic value for chronic kidney disease between 640-slice computed tomography kidney scan and conventional computed tomography scan
topic Research Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9433217/
https://www.ncbi.nlm.nih.gov/pubmed/36082054
http://dx.doi.org/10.1155/2022/6587617
work_keys_str_mv AT zhaoyusen comparisonofdiagnosticvalueforchronickidneydiseasebetween640slicecomputedtomographykidneyscanandconventionalcomputedtomographyscan
AT wangyaoyi comparisonofdiagnosticvalueforchronickidneydiseasebetween640slicecomputedtomographykidneyscanandconventionalcomputedtomographyscan
AT xuyuanbo comparisonofdiagnosticvalueforchronickidneydiseasebetween640slicecomputedtomographykidneyscanandconventionalcomputedtomographyscan
AT zhaoyijie comparisonofdiagnosticvalueforchronickidneydiseasebetween640slicecomputedtomographykidneyscanandconventionalcomputedtomographyscan
AT quyingwu comparisonofdiagnosticvalueforchronickidneydiseasebetween640slicecomputedtomographykidneyscanandconventionalcomputedtomographyscan
AT zhanghua comparisonofdiagnosticvalueforchronickidneydiseasebetween640slicecomputedtomographykidneyscanandconventionalcomputedtomographyscan
AT zhangzhimin comparisonofdiagnosticvalueforchronickidneydiseasebetween640slicecomputedtomographykidneyscanandconventionalcomputedtomographyscan
AT huzhenshun comparisonofdiagnosticvalueforchronickidneydiseasebetween640slicecomputedtomographykidneyscanandconventionalcomputedtomographyscan
AT zhuxiaolong comparisonofdiagnosticvalueforchronickidneydiseasebetween640slicecomputedtomographykidneyscanandconventionalcomputedtomographyscan
AT cuishujun comparisonofdiagnosticvalueforchronickidneydiseasebetween640slicecomputedtomographykidneyscanandconventionalcomputedtomographyscan
AT xiejin comparisonofdiagnosticvalueforchronickidneydiseasebetween640slicecomputedtomographykidneyscanandconventionalcomputedtomographyscan