Cargando…

A rare case of delayed splenic rupture following initial negative CT scan imaging: A case report and review of the literature

INTRODUCTION: Delayed splenic rupture is an often unpredictable event with high mortality. In this report, we discuss the successful management of delayed splenic rupture, presenting days after index injury, with no commonly associated injuries or blunt abdominal trauma. CASE PRESENTATION: A 50 year...

Descripción completa

Detalles Bibliográficos
Autores principales: Carlin, Margo, Elkbuli, Adel, Maka, Piueti, McKenney, Mark, Boneva, Dessy
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Elsevier 2022
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9434024/
https://www.ncbi.nlm.nih.gov/pubmed/36030762
http://dx.doi.org/10.1016/j.ijscr.2022.107517
_version_ 1784780771332980736
author Carlin, Margo
Elkbuli, Adel
Maka, Piueti
McKenney, Mark
Boneva, Dessy
author_facet Carlin, Margo
Elkbuli, Adel
Maka, Piueti
McKenney, Mark
Boneva, Dessy
author_sort Carlin, Margo
collection PubMed
description INTRODUCTION: Delayed splenic rupture is an often unpredictable event with high mortality. In this report, we discuss the successful management of delayed splenic rupture, presenting days after index injury, with no commonly associated injuries or blunt abdominal trauma. CASE PRESENTATION: A 50 year old male, not on anticoagulants, presented with blunt trauma after driving his motorcycle into a tree. The patient sustained right 3–5 rib fractures, displaced right midclavicular fracture, 25 % right pneumothorax, T5–9 posterior spinous process fractures, left 2nd-5th metatarsal fractures, and scattered abrasions to the left foot, knee and hand. Focused abdominal sonography for trauma (FAST) and admission abdominal multi-detector CT were negative for any intra-abdominal injuries. On hospital day 5, the patient acutely decompensated. FAST was grossly positive and emergent laparotomy revealed a splenic rupture. After a splenectomy, he recovered. DISCUSSION: The spleen is the most commonly injured organ in blunt abdominal trauma. Although acute injury often presents with imaging findings or sequelae of hemorrhagic shock, complications of splenic trauma have the potential to result in delayed catastrophe. Bedside ultrasonography is a useful tool to assess acute decompensation in trauma patients along with CT imaging. Prompt identification and hemorrhage control are crucial to survival after trauma. CONCLUSION: Repeat CT scans are also important for the identification of delayed splenic rupture and timely intervention. Delayed hemorrhage after blunt trauma should never be ruled out regardless of the injury complexity or length of hospital admission.
format Online
Article
Text
id pubmed-9434024
institution National Center for Biotechnology Information
language English
publishDate 2022
publisher Elsevier
record_format MEDLINE/PubMed
spelling pubmed-94340242022-09-02 A rare case of delayed splenic rupture following initial negative CT scan imaging: A case report and review of the literature Carlin, Margo Elkbuli, Adel Maka, Piueti McKenney, Mark Boneva, Dessy Int J Surg Case Rep Case Report INTRODUCTION: Delayed splenic rupture is an often unpredictable event with high mortality. In this report, we discuss the successful management of delayed splenic rupture, presenting days after index injury, with no commonly associated injuries or blunt abdominal trauma. CASE PRESENTATION: A 50 year old male, not on anticoagulants, presented with blunt trauma after driving his motorcycle into a tree. The patient sustained right 3–5 rib fractures, displaced right midclavicular fracture, 25 % right pneumothorax, T5–9 posterior spinous process fractures, left 2nd-5th metatarsal fractures, and scattered abrasions to the left foot, knee and hand. Focused abdominal sonography for trauma (FAST) and admission abdominal multi-detector CT were negative for any intra-abdominal injuries. On hospital day 5, the patient acutely decompensated. FAST was grossly positive and emergent laparotomy revealed a splenic rupture. After a splenectomy, he recovered. DISCUSSION: The spleen is the most commonly injured organ in blunt abdominal trauma. Although acute injury often presents with imaging findings or sequelae of hemorrhagic shock, complications of splenic trauma have the potential to result in delayed catastrophe. Bedside ultrasonography is a useful tool to assess acute decompensation in trauma patients along with CT imaging. Prompt identification and hemorrhage control are crucial to survival after trauma. CONCLUSION: Repeat CT scans are also important for the identification of delayed splenic rupture and timely intervention. Delayed hemorrhage after blunt trauma should never be ruled out regardless of the injury complexity or length of hospital admission. Elsevier 2022-08-13 /pmc/articles/PMC9434024/ /pubmed/36030762 http://dx.doi.org/10.1016/j.ijscr.2022.107517 Text en © 2022 The Authors. Published by Elsevier Ltd on behalf of IJS Publishing Group Ltd. https://creativecommons.org/licenses/by/4.0/This is an open access article under the CC BY license (http://creativecommons.org/licenses/by/4.0/).
spellingShingle Case Report
Carlin, Margo
Elkbuli, Adel
Maka, Piueti
McKenney, Mark
Boneva, Dessy
A rare case of delayed splenic rupture following initial negative CT scan imaging: A case report and review of the literature
title A rare case of delayed splenic rupture following initial negative CT scan imaging: A case report and review of the literature
title_full A rare case of delayed splenic rupture following initial negative CT scan imaging: A case report and review of the literature
title_fullStr A rare case of delayed splenic rupture following initial negative CT scan imaging: A case report and review of the literature
title_full_unstemmed A rare case of delayed splenic rupture following initial negative CT scan imaging: A case report and review of the literature
title_short A rare case of delayed splenic rupture following initial negative CT scan imaging: A case report and review of the literature
title_sort rare case of delayed splenic rupture following initial negative ct scan imaging: a case report and review of the literature
topic Case Report
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9434024/
https://www.ncbi.nlm.nih.gov/pubmed/36030762
http://dx.doi.org/10.1016/j.ijscr.2022.107517
work_keys_str_mv AT carlinmargo ararecaseofdelayedsplenicrupturefollowinginitialnegativectscanimagingacasereportandreviewoftheliterature
AT elkbuliadel ararecaseofdelayedsplenicrupturefollowinginitialnegativectscanimagingacasereportandreviewoftheliterature
AT makapiueti ararecaseofdelayedsplenicrupturefollowinginitialnegativectscanimagingacasereportandreviewoftheliterature
AT mckenneymark ararecaseofdelayedsplenicrupturefollowinginitialnegativectscanimagingacasereportandreviewoftheliterature
AT bonevadessy ararecaseofdelayedsplenicrupturefollowinginitialnegativectscanimagingacasereportandreviewoftheliterature
AT carlinmargo rarecaseofdelayedsplenicrupturefollowinginitialnegativectscanimagingacasereportandreviewoftheliterature
AT elkbuliadel rarecaseofdelayedsplenicrupturefollowinginitialnegativectscanimagingacasereportandreviewoftheliterature
AT makapiueti rarecaseofdelayedsplenicrupturefollowinginitialnegativectscanimagingacasereportandreviewoftheliterature
AT mckenneymark rarecaseofdelayedsplenicrupturefollowinginitialnegativectscanimagingacasereportandreviewoftheliterature
AT bonevadessy rarecaseofdelayedsplenicrupturefollowinginitialnegativectscanimagingacasereportandreviewoftheliterature