Cargando…
Performance evaluation of antigen detection rapid diagnostic test (Ag-RDT) for COVID-19 diagnosis in a primary healthcare center during the Shanghai COVID-19 quarantine period
BACKGROUND: Rapid and accurate detection of SARS-CoV-2 infection is the cornerstone of prompt patient care. However, the reliability of the antigen rapid diagnostic test (Ag-RDT) in the diagnosis of SARS-CoV-2 infection remains inconclusive. METHODS: We conducted a field evaluation of Ag-RDT perform...
Autores principales: | , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
BioMed Central
2022
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9434095/ https://www.ncbi.nlm.nih.gov/pubmed/36050725 http://dx.doi.org/10.1186/s12985-022-01871-6 |
_version_ | 1784780791410065408 |
---|---|
author | Dong, Lan Li, Wen-Fang Jiang, Ying |
author_facet | Dong, Lan Li, Wen-Fang Jiang, Ying |
author_sort | Dong, Lan |
collection | PubMed |
description | BACKGROUND: Rapid and accurate detection of SARS-CoV-2 infection is the cornerstone of prompt patient care. However, the reliability of the antigen rapid diagnostic test (Ag-RDT) in the diagnosis of SARS-CoV-2 infection remains inconclusive. METHODS: We conducted a field evaluation of Ag-RDT performance during the Shanghai Coronavirus disease 2019 (COVID-19) quarantine and screened 7225 individuals visiting our Emergency Department. 83 asymptomatic SARS-CoV-2 (+) individuals were enrolled in the current study. Simultaneously, Ag-RDT was performed to evaluate its testing performance. RESULTS: For the Ag-RDT(−) cases, the average cycle threshold (Ct) values of the N gene were 27.26 ± 4.59, which were significantly higher than the Ct value (21.9 ± 4.73) of the Ag-RDT(+) individuals (p < 0.0001). The overall sensitivity of Ag-RDT versus that of RT-PCR was 43.37%. The Ag-RDT(+) individuals regarding the N gene’s Ct value were 16 cases in the < 20 range, 12 in 20–25, 5 in 25–30, and 3 in 30–35. The corresponding sensitivity was 84.21%, 52.17%, 21.74% and 16.67%, respectively. Meanwhile, sampling had a straight specificity of 100% regardless of the Ct value. CONCLUSIONS: The Ag-RDT were extremely sensitive in asymptomatic COVID-19 individuals with a Ct value < 20. |
format | Online Article Text |
id | pubmed-9434095 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2022 |
publisher | BioMed Central |
record_format | MEDLINE/PubMed |
spelling | pubmed-94340952022-09-01 Performance evaluation of antigen detection rapid diagnostic test (Ag-RDT) for COVID-19 diagnosis in a primary healthcare center during the Shanghai COVID-19 quarantine period Dong, Lan Li, Wen-Fang Jiang, Ying Virol J Research BACKGROUND: Rapid and accurate detection of SARS-CoV-2 infection is the cornerstone of prompt patient care. However, the reliability of the antigen rapid diagnostic test (Ag-RDT) in the diagnosis of SARS-CoV-2 infection remains inconclusive. METHODS: We conducted a field evaluation of Ag-RDT performance during the Shanghai Coronavirus disease 2019 (COVID-19) quarantine and screened 7225 individuals visiting our Emergency Department. 83 asymptomatic SARS-CoV-2 (+) individuals were enrolled in the current study. Simultaneously, Ag-RDT was performed to evaluate its testing performance. RESULTS: For the Ag-RDT(−) cases, the average cycle threshold (Ct) values of the N gene were 27.26 ± 4.59, which were significantly higher than the Ct value (21.9 ± 4.73) of the Ag-RDT(+) individuals (p < 0.0001). The overall sensitivity of Ag-RDT versus that of RT-PCR was 43.37%. The Ag-RDT(+) individuals regarding the N gene’s Ct value were 16 cases in the < 20 range, 12 in 20–25, 5 in 25–30, and 3 in 30–35. The corresponding sensitivity was 84.21%, 52.17%, 21.74% and 16.67%, respectively. Meanwhile, sampling had a straight specificity of 100% regardless of the Ct value. CONCLUSIONS: The Ag-RDT were extremely sensitive in asymptomatic COVID-19 individuals with a Ct value < 20. BioMed Central 2022-09-01 /pmc/articles/PMC9434095/ /pubmed/36050725 http://dx.doi.org/10.1186/s12985-022-01871-6 Text en © The Author(s) 2022 https://creativecommons.org/licenses/by/4.0/Open AccessThis article is licensed under a Creative Commons Attribution 4.0 International License, which permits use, sharing, adaptation, distribution and reproduction in any medium or format, as long as you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons licence, and indicate if changes were made. The images or other third party material in this article are included in the article's Creative Commons licence, unless indicated otherwise in a credit line to the material. If material is not included in the article's Creative Commons licence and your intended use is not permitted by statutory regulation or exceeds the permitted use, you will need to obtain permission directly from the copyright holder. To view a copy of this licence, visit http://creativecommons.org/licenses/by/4.0/ (https://creativecommons.org/licenses/by/4.0/) . The Creative Commons Public Domain Dedication waiver (http://creativecommons.org/publicdomain/zero/1.0/ (https://creativecommons.org/publicdomain/zero/1.0/) ) applies to the data made available in this article, unless otherwise stated in a credit line to the data. |
spellingShingle | Research Dong, Lan Li, Wen-Fang Jiang, Ying Performance evaluation of antigen detection rapid diagnostic test (Ag-RDT) for COVID-19 diagnosis in a primary healthcare center during the Shanghai COVID-19 quarantine period |
title | Performance evaluation of antigen detection rapid diagnostic test (Ag-RDT) for COVID-19 diagnosis in a primary healthcare center during the Shanghai COVID-19 quarantine period |
title_full | Performance evaluation of antigen detection rapid diagnostic test (Ag-RDT) for COVID-19 diagnosis in a primary healthcare center during the Shanghai COVID-19 quarantine period |
title_fullStr | Performance evaluation of antigen detection rapid diagnostic test (Ag-RDT) for COVID-19 diagnosis in a primary healthcare center during the Shanghai COVID-19 quarantine period |
title_full_unstemmed | Performance evaluation of antigen detection rapid diagnostic test (Ag-RDT) for COVID-19 diagnosis in a primary healthcare center during the Shanghai COVID-19 quarantine period |
title_short | Performance evaluation of antigen detection rapid diagnostic test (Ag-RDT) for COVID-19 diagnosis in a primary healthcare center during the Shanghai COVID-19 quarantine period |
title_sort | performance evaluation of antigen detection rapid diagnostic test (ag-rdt) for covid-19 diagnosis in a primary healthcare center during the shanghai covid-19 quarantine period |
topic | Research |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9434095/ https://www.ncbi.nlm.nih.gov/pubmed/36050725 http://dx.doi.org/10.1186/s12985-022-01871-6 |
work_keys_str_mv | AT donglan performanceevaluationofantigendetectionrapiddiagnostictestagrdtforcovid19diagnosisinaprimaryhealthcarecenterduringtheshanghaicovid19quarantineperiod AT liwenfang performanceevaluationofantigendetectionrapiddiagnostictestagrdtforcovid19diagnosisinaprimaryhealthcarecenterduringtheshanghaicovid19quarantineperiod AT jiangying performanceevaluationofantigendetectionrapiddiagnostictestagrdtforcovid19diagnosisinaprimaryhealthcarecenterduringtheshanghaicovid19quarantineperiod |