Real-Time On-Site Multielement Analysis of Environmental Waters with a Portable X-ray Fluorescence (pXRF) System

[Image: see text] Strict regulations are in place to control the effluents of mining sites and other industries. Heavy metal contamination of aquatic systems caused by leakages is difficult to mitigate as it takes time to detect and localize the leak. Dynamic sampling would drastically reduce the ti...

Descripción completa

Detalles Bibliográficos
Autores principales: Tiihonen, Tommi E., Nissinen, Tuomo J., Turhanen, Petri A., Vepsäläinen, Jouko J., Riikonen, Joakim, Lehto, Vesa-Pekka
Formato: Online Artículo Texto
Lenguaje:English
Publicado: American Chemical Society 2022
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9434549/
https://www.ncbi.nlm.nih.gov/pubmed/35972396
http://dx.doi.org/10.1021/acs.analchem.2c01490
_version_ 1784780895478087680
author Tiihonen, Tommi E.
Nissinen, Tuomo J.
Turhanen, Petri A.
Vepsäläinen, Jouko J.
Riikonen, Joakim
Lehto, Vesa-Pekka
author_facet Tiihonen, Tommi E.
Nissinen, Tuomo J.
Turhanen, Petri A.
Vepsäläinen, Jouko J.
Riikonen, Joakim
Lehto, Vesa-Pekka
author_sort Tiihonen, Tommi E.
collection PubMed
description [Image: see text] Strict regulations are in place to control the effluents of mining sites and other industries. Heavy metal contamination of aquatic systems caused by leakages is difficult to mitigate as it takes time to detect and localize the leak. Dynamic sampling would drastically reduce the time to locate leakages and allow faster actions to reduce the impact on the environment. The present study introduces a novel portable multielement water analysis system to simultaneously measure Mn, Ni, Cu, Zn, Pb, and U in water samples from natural sources within 15 min from the sampling. The metals are preconcentrated from a 10 mL water sample into a nanoporous filter based on bisphosphonate-modified thermally carbonized porous silicon. The metals can be conveniently analyzed from the filter with a portable XRF analyzer in field conditions. The system was empirically calibrated for a lake water matrix with neutral pH and low alkaline metal concentration. A strong correlation between the XRF intensities and the ICP-MS results was obtained in a concentration range from 50 to 10 000 μg/L. With a DPO-2000C XRF analyzer, the detection limits were 103, 86, 92, 35, 44, and 43 μg/L for Mn, Ni, Cu, Zn, Pb, and U, respectively. The corresponding values with X-MET8000 Expert Geo were 137, 46, 62, 38, 29, and 54. The system was successfully validated with simulated multielement lake water samples and piloted in field conditions. The system provides an efficient way to monitor metals in environmental waters in cases where quick on-site results are needed.
format Online
Article
Text
id pubmed-9434549
institution National Center for Biotechnology Information
language English
publishDate 2022
publisher American Chemical Society
record_format MEDLINE/PubMed
spelling pubmed-94345492022-09-02 Real-Time On-Site Multielement Analysis of Environmental Waters with a Portable X-ray Fluorescence (pXRF) System Tiihonen, Tommi E. Nissinen, Tuomo J. Turhanen, Petri A. Vepsäläinen, Jouko J. Riikonen, Joakim Lehto, Vesa-Pekka Anal Chem [Image: see text] Strict regulations are in place to control the effluents of mining sites and other industries. Heavy metal contamination of aquatic systems caused by leakages is difficult to mitigate as it takes time to detect and localize the leak. Dynamic sampling would drastically reduce the time to locate leakages and allow faster actions to reduce the impact on the environment. The present study introduces a novel portable multielement water analysis system to simultaneously measure Mn, Ni, Cu, Zn, Pb, and U in water samples from natural sources within 15 min from the sampling. The metals are preconcentrated from a 10 mL water sample into a nanoporous filter based on bisphosphonate-modified thermally carbonized porous silicon. The metals can be conveniently analyzed from the filter with a portable XRF analyzer in field conditions. The system was empirically calibrated for a lake water matrix with neutral pH and low alkaline metal concentration. A strong correlation between the XRF intensities and the ICP-MS results was obtained in a concentration range from 50 to 10 000 μg/L. With a DPO-2000C XRF analyzer, the detection limits were 103, 86, 92, 35, 44, and 43 μg/L for Mn, Ni, Cu, Zn, Pb, and U, respectively. The corresponding values with X-MET8000 Expert Geo were 137, 46, 62, 38, 29, and 54. The system was successfully validated with simulated multielement lake water samples and piloted in field conditions. The system provides an efficient way to monitor metals in environmental waters in cases where quick on-site results are needed. American Chemical Society 2022-08-16 2022-08-30 /pmc/articles/PMC9434549/ /pubmed/35972396 http://dx.doi.org/10.1021/acs.analchem.2c01490 Text en © 2022 The Authors. Published by American Chemical Society https://creativecommons.org/licenses/by/4.0/Permits the broadest form of re-use including for commercial purposes, provided that author attribution and integrity are maintained (https://creativecommons.org/licenses/by/4.0/).
spellingShingle Tiihonen, Tommi E.
Nissinen, Tuomo J.
Turhanen, Petri A.
Vepsäläinen, Jouko J.
Riikonen, Joakim
Lehto, Vesa-Pekka
Real-Time On-Site Multielement Analysis of Environmental Waters with a Portable X-ray Fluorescence (pXRF) System
title Real-Time On-Site Multielement Analysis of Environmental Waters with a Portable X-ray Fluorescence (pXRF) System
title_full Real-Time On-Site Multielement Analysis of Environmental Waters with a Portable X-ray Fluorescence (pXRF) System
title_fullStr Real-Time On-Site Multielement Analysis of Environmental Waters with a Portable X-ray Fluorescence (pXRF) System
title_full_unstemmed Real-Time On-Site Multielement Analysis of Environmental Waters with a Portable X-ray Fluorescence (pXRF) System
title_short Real-Time On-Site Multielement Analysis of Environmental Waters with a Portable X-ray Fluorescence (pXRF) System
title_sort real-time on-site multielement analysis of environmental waters with a portable x-ray fluorescence (pxrf) system
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9434549/
https://www.ncbi.nlm.nih.gov/pubmed/35972396
http://dx.doi.org/10.1021/acs.analchem.2c01490
work_keys_str_mv AT tiihonentommie realtimeonsitemultielementanalysisofenvironmentalwaterswithaportablexrayfluorescencepxrfsystem
AT nissinentuomoj realtimeonsitemultielementanalysisofenvironmentalwaterswithaportablexrayfluorescencepxrfsystem
AT turhanenpetria realtimeonsitemultielementanalysisofenvironmentalwaterswithaportablexrayfluorescencepxrfsystem
AT vepsalainenjoukoj realtimeonsitemultielementanalysisofenvironmentalwaterswithaportablexrayfluorescencepxrfsystem
AT riikonenjoakim realtimeonsitemultielementanalysisofenvironmentalwaterswithaportablexrayfluorescencepxrfsystem
AT lehtovesapekka realtimeonsitemultielementanalysisofenvironmentalwaterswithaportablexrayfluorescencepxrfsystem