Cargando…

Indirect comparison between powered and manual circular staplers for left-sided colorectal anastomoses: clinical and economic outcomes in China

AIMS: This study aimed to examine the economic and clinical benefits of a new powered circular stapler for left-sided colorectal construction in China. METHODS: A decision analysis model was constructed for a cohort of adult patients who underwent left-sided colorectal anastomoses, using either the...

Descripción completa

Detalles Bibliográficos
Autores principales: Bai, Junwei, Zhao, Yingnan, Liang, Hong, Li, Junmeng, Zhang, Chao
Formato: Online Artículo Texto
Lenguaje:English
Publicado: BioMed Central 2022
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9434853/
https://www.ncbi.nlm.nih.gov/pubmed/36045434
http://dx.doi.org/10.1186/s12962-022-00380-1
_version_ 1784780974123384832
author Bai, Junwei
Zhao, Yingnan
Liang, Hong
Li, Junmeng
Zhang, Chao
author_facet Bai, Junwei
Zhao, Yingnan
Liang, Hong
Li, Junmeng
Zhang, Chao
author_sort Bai, Junwei
collection PubMed
description AIMS: This study aimed to examine the economic and clinical benefits of a new powered circular stapler for left-sided colorectal construction in China. METHODS: A decision analysis model was constructed for a cohort of adult patients who underwent left-sided colorectal anastomoses, using either the Echelon Circular Powered (ECP) stapler) or the conventional manual circular staplers (MCS). The complications rates and healthcare resource utilization in the ECP cohort were obtained from the single-arm ECP trial (NCT03326895). For the MCS cohort, retrospective data from 20 Chinese hospitals were analyzed. Listing prices were used to estimate the costs of the staplers in China. Propensity score matching (PSM) was employed to adjust for the imbalance between the two cohorts. Anastomotic leak rate, length of stay (LOS), 90-day readmission rate, and direct medical costs were used for the decision analysis model parameters. A budget impact analysis was conducted to compare the total hospitalization expenditure between ECP and manual circular staplers from the hospital’s perspective in China. RESULTS: Assuming 100 procedures per year, the anastomotic leak rate was 1.79 and 29.76 per 100 procedures in the ECP and MCS cohorts, respectively. LOS was 1,426.91 days in the ECP cohort, compared to 1,702.38 days in the MCS cohort. The 90-day readmission rate was also lower in the ECP cohort than the MCS cohort (19.10 vs. 26.19 per 100 procedures). For the 100 procedures, the annual total hospitalization costs for left-sided colorectal anastomosis were reduced from ¥7,152,251 using manual circular staplers to ¥6,919,306 using ECP. Despite a higher acquisition cost of ECP compared to the manual staplers (¥711,200 vs. ¥441,700), an annual saving of ¥232,945in the total cost resulted from lower rates of complications and shorter LOS. Sensitivity analyses presented consistent savings using ECP, and the ECP cost and cost of the index hospitalization with anastomotic leak were found the most influencing factors. CONCLUSIONS: There were clinical and economic benefits of ECP, compared to manual circular staplers for left-sided colorectal anastomoses. Further direct comparative studies on the use of ECP in practice in Chinese hospital settings are warranted.
format Online
Article
Text
id pubmed-9434853
institution National Center for Biotechnology Information
language English
publishDate 2022
publisher BioMed Central
record_format MEDLINE/PubMed
spelling pubmed-94348532022-09-02 Indirect comparison between powered and manual circular staplers for left-sided colorectal anastomoses: clinical and economic outcomes in China Bai, Junwei Zhao, Yingnan Liang, Hong Li, Junmeng Zhang, Chao Cost Eff Resour Alloc Research AIMS: This study aimed to examine the economic and clinical benefits of a new powered circular stapler for left-sided colorectal construction in China. METHODS: A decision analysis model was constructed for a cohort of adult patients who underwent left-sided colorectal anastomoses, using either the Echelon Circular Powered (ECP) stapler) or the conventional manual circular staplers (MCS). The complications rates and healthcare resource utilization in the ECP cohort were obtained from the single-arm ECP trial (NCT03326895). For the MCS cohort, retrospective data from 20 Chinese hospitals were analyzed. Listing prices were used to estimate the costs of the staplers in China. Propensity score matching (PSM) was employed to adjust for the imbalance between the two cohorts. Anastomotic leak rate, length of stay (LOS), 90-day readmission rate, and direct medical costs were used for the decision analysis model parameters. A budget impact analysis was conducted to compare the total hospitalization expenditure between ECP and manual circular staplers from the hospital’s perspective in China. RESULTS: Assuming 100 procedures per year, the anastomotic leak rate was 1.79 and 29.76 per 100 procedures in the ECP and MCS cohorts, respectively. LOS was 1,426.91 days in the ECP cohort, compared to 1,702.38 days in the MCS cohort. The 90-day readmission rate was also lower in the ECP cohort than the MCS cohort (19.10 vs. 26.19 per 100 procedures). For the 100 procedures, the annual total hospitalization costs for left-sided colorectal anastomosis were reduced from ¥7,152,251 using manual circular staplers to ¥6,919,306 using ECP. Despite a higher acquisition cost of ECP compared to the manual staplers (¥711,200 vs. ¥441,700), an annual saving of ¥232,945in the total cost resulted from lower rates of complications and shorter LOS. Sensitivity analyses presented consistent savings using ECP, and the ECP cost and cost of the index hospitalization with anastomotic leak were found the most influencing factors. CONCLUSIONS: There were clinical and economic benefits of ECP, compared to manual circular staplers for left-sided colorectal anastomoses. Further direct comparative studies on the use of ECP in practice in Chinese hospital settings are warranted. BioMed Central 2022-08-31 /pmc/articles/PMC9434853/ /pubmed/36045434 http://dx.doi.org/10.1186/s12962-022-00380-1 Text en © The Author(s) 2022 https://creativecommons.org/licenses/by/4.0/Open AccessThis article is licensed under a Creative Commons Attribution 4.0 International License, which permits use, sharing, adaptation, distribution and reproduction in any medium or format, as long as you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons licence, and indicate if changes were made. The images or other third party material in this article are included in the article's Creative Commons licence, unless indicated otherwise in a credit line to the material. If material is not included in the article's Creative Commons licence and your intended use is not permitted by statutory regulation or exceeds the permitted use, you will need to obtain permission directly from the copyright holder. To view a copy of this licence, visit http://creativecommons.org/licenses/by/4.0/ (https://creativecommons.org/licenses/by/4.0/) . The Creative Commons Public Domain Dedication waiver (http://creativecommons.org/publicdomain/zero/1.0/ (https://creativecommons.org/publicdomain/zero/1.0/) ) applies to the data made available in this article, unless otherwise stated in a credit line to the data.
spellingShingle Research
Bai, Junwei
Zhao, Yingnan
Liang, Hong
Li, Junmeng
Zhang, Chao
Indirect comparison between powered and manual circular staplers for left-sided colorectal anastomoses: clinical and economic outcomes in China
title Indirect comparison between powered and manual circular staplers for left-sided colorectal anastomoses: clinical and economic outcomes in China
title_full Indirect comparison between powered and manual circular staplers for left-sided colorectal anastomoses: clinical and economic outcomes in China
title_fullStr Indirect comparison between powered and manual circular staplers for left-sided colorectal anastomoses: clinical and economic outcomes in China
title_full_unstemmed Indirect comparison between powered and manual circular staplers for left-sided colorectal anastomoses: clinical and economic outcomes in China
title_short Indirect comparison between powered and manual circular staplers for left-sided colorectal anastomoses: clinical and economic outcomes in China
title_sort indirect comparison between powered and manual circular staplers for left-sided colorectal anastomoses: clinical and economic outcomes in china
topic Research
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9434853/
https://www.ncbi.nlm.nih.gov/pubmed/36045434
http://dx.doi.org/10.1186/s12962-022-00380-1
work_keys_str_mv AT baijunwei indirectcomparisonbetweenpoweredandmanualcircularstaplersforleftsidedcolorectalanastomosesclinicalandeconomicoutcomesinchina
AT zhaoyingnan indirectcomparisonbetweenpoweredandmanualcircularstaplersforleftsidedcolorectalanastomosesclinicalandeconomicoutcomesinchina
AT lianghong indirectcomparisonbetweenpoweredandmanualcircularstaplersforleftsidedcolorectalanastomosesclinicalandeconomicoutcomesinchina
AT lijunmeng indirectcomparisonbetweenpoweredandmanualcircularstaplersforleftsidedcolorectalanastomosesclinicalandeconomicoutcomesinchina
AT zhangchao indirectcomparisonbetweenpoweredandmanualcircularstaplersforleftsidedcolorectalanastomosesclinicalandeconomicoutcomesinchina