Cargando…

Minimally invasive transiliac anatomical locking plate for posterior pelvic ring injury: A technical trick of the gull wing plate

Posterior pelvic ring injuries commonly involve sacral fractures, which are difficult to reduce and stabilize. Because conservative treatment requires long-term bedrest and leads to unsatisfactory outcomes, surgical intervention is a beneficial option to protect neurological structures and provide s...

Descripción completa

Detalles Bibliográficos
Autores principales: Mitsuzawa, Sadaki, Kusakabe, Kenji, Matsuda, Shuichi
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Elsevier 2022
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9436802/
https://www.ncbi.nlm.nih.gov/pubmed/36061970
http://dx.doi.org/10.1016/j.jcot.2022.101991
_version_ 1784781453365608448
author Mitsuzawa, Sadaki
Kusakabe, Kenji
Matsuda, Shuichi
author_facet Mitsuzawa, Sadaki
Kusakabe, Kenji
Matsuda, Shuichi
author_sort Mitsuzawa, Sadaki
collection PubMed
description Posterior pelvic ring injuries commonly involve sacral fractures, which are difficult to reduce and stabilize. Because conservative treatment requires long-term bedrest and leads to unsatisfactory outcomes, surgical intervention is a beneficial option to protect neurological structures and provide sufficient stability for early mobilization. Several studies have investigated a variety of internal fixation techniques, such as iliosacral screws, transiliac bars, spinal instruments, and transiliac plates. The gull wing plate (GWP) is a pre-contoured anatomical locking plate with two cancellous screws (φ6.5 mm) and four locking screws (φ5.0 mm), the design of which is unique among posterior tension-band plates. The GWP provides reliable stability of the posterior construct of the pelvic ring and accelerates rehabilitation. Compared to alternative surgical techniques for posterior fixation, the simple surgical procedure of the GWP is minimally invasive and highly reproducible, which leads to fewer complications and less radiation exposure.
format Online
Article
Text
id pubmed-9436802
institution National Center for Biotechnology Information
language English
publishDate 2022
publisher Elsevier
record_format MEDLINE/PubMed
spelling pubmed-94368022023-08-19 Minimally invasive transiliac anatomical locking plate for posterior pelvic ring injury: A technical trick of the gull wing plate Mitsuzawa, Sadaki Kusakabe, Kenji Matsuda, Shuichi J Clin Orthop Trauma Case Report Posterior pelvic ring injuries commonly involve sacral fractures, which are difficult to reduce and stabilize. Because conservative treatment requires long-term bedrest and leads to unsatisfactory outcomes, surgical intervention is a beneficial option to protect neurological structures and provide sufficient stability for early mobilization. Several studies have investigated a variety of internal fixation techniques, such as iliosacral screws, transiliac bars, spinal instruments, and transiliac plates. The gull wing plate (GWP) is a pre-contoured anatomical locking plate with two cancellous screws (φ6.5 mm) and four locking screws (φ5.0 mm), the design of which is unique among posterior tension-band plates. The GWP provides reliable stability of the posterior construct of the pelvic ring and accelerates rehabilitation. Compared to alternative surgical techniques for posterior fixation, the simple surgical procedure of the GWP is minimally invasive and highly reproducible, which leads to fewer complications and less radiation exposure. Elsevier 2022-08-19 /pmc/articles/PMC9436802/ /pubmed/36061970 http://dx.doi.org/10.1016/j.jcot.2022.101991 Text en © 2022 The Authors https://creativecommons.org/licenses/by-nc-nd/4.0/This is an open access article under the CC BY-NC-ND license (http://creativecommons.org/licenses/by-nc-nd/4.0/).
spellingShingle Case Report
Mitsuzawa, Sadaki
Kusakabe, Kenji
Matsuda, Shuichi
Minimally invasive transiliac anatomical locking plate for posterior pelvic ring injury: A technical trick of the gull wing plate
title Minimally invasive transiliac anatomical locking plate for posterior pelvic ring injury: A technical trick of the gull wing plate
title_full Minimally invasive transiliac anatomical locking plate for posterior pelvic ring injury: A technical trick of the gull wing plate
title_fullStr Minimally invasive transiliac anatomical locking plate for posterior pelvic ring injury: A technical trick of the gull wing plate
title_full_unstemmed Minimally invasive transiliac anatomical locking plate for posterior pelvic ring injury: A technical trick of the gull wing plate
title_short Minimally invasive transiliac anatomical locking plate for posterior pelvic ring injury: A technical trick of the gull wing plate
title_sort minimally invasive transiliac anatomical locking plate for posterior pelvic ring injury: a technical trick of the gull wing plate
topic Case Report
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9436802/
https://www.ncbi.nlm.nih.gov/pubmed/36061970
http://dx.doi.org/10.1016/j.jcot.2022.101991
work_keys_str_mv AT mitsuzawasadaki minimallyinvasivetransiliacanatomicallockingplateforposteriorpelvicringinjuryatechnicaltrickofthegullwingplate
AT kusakabekenji minimallyinvasivetransiliacanatomicallockingplateforposteriorpelvicringinjuryatechnicaltrickofthegullwingplate
AT matsudashuichi minimallyinvasivetransiliacanatomicallockingplateforposteriorpelvicringinjuryatechnicaltrickofthegullwingplate