Cargando…
Minimally invasive transiliac anatomical locking plate for posterior pelvic ring injury: A technical trick of the gull wing plate
Posterior pelvic ring injuries commonly involve sacral fractures, which are difficult to reduce and stabilize. Because conservative treatment requires long-term bedrest and leads to unsatisfactory outcomes, surgical intervention is a beneficial option to protect neurological structures and provide s...
Autores principales: | , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Elsevier
2022
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9436802/ https://www.ncbi.nlm.nih.gov/pubmed/36061970 http://dx.doi.org/10.1016/j.jcot.2022.101991 |
_version_ | 1784781453365608448 |
---|---|
author | Mitsuzawa, Sadaki Kusakabe, Kenji Matsuda, Shuichi |
author_facet | Mitsuzawa, Sadaki Kusakabe, Kenji Matsuda, Shuichi |
author_sort | Mitsuzawa, Sadaki |
collection | PubMed |
description | Posterior pelvic ring injuries commonly involve sacral fractures, which are difficult to reduce and stabilize. Because conservative treatment requires long-term bedrest and leads to unsatisfactory outcomes, surgical intervention is a beneficial option to protect neurological structures and provide sufficient stability for early mobilization. Several studies have investigated a variety of internal fixation techniques, such as iliosacral screws, transiliac bars, spinal instruments, and transiliac plates. The gull wing plate (GWP) is a pre-contoured anatomical locking plate with two cancellous screws (φ6.5 mm) and four locking screws (φ5.0 mm), the design of which is unique among posterior tension-band plates. The GWP provides reliable stability of the posterior construct of the pelvic ring and accelerates rehabilitation. Compared to alternative surgical techniques for posterior fixation, the simple surgical procedure of the GWP is minimally invasive and highly reproducible, which leads to fewer complications and less radiation exposure. |
format | Online Article Text |
id | pubmed-9436802 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2022 |
publisher | Elsevier |
record_format | MEDLINE/PubMed |
spelling | pubmed-94368022023-08-19 Minimally invasive transiliac anatomical locking plate for posterior pelvic ring injury: A technical trick of the gull wing plate Mitsuzawa, Sadaki Kusakabe, Kenji Matsuda, Shuichi J Clin Orthop Trauma Case Report Posterior pelvic ring injuries commonly involve sacral fractures, which are difficult to reduce and stabilize. Because conservative treatment requires long-term bedrest and leads to unsatisfactory outcomes, surgical intervention is a beneficial option to protect neurological structures and provide sufficient stability for early mobilization. Several studies have investigated a variety of internal fixation techniques, such as iliosacral screws, transiliac bars, spinal instruments, and transiliac plates. The gull wing plate (GWP) is a pre-contoured anatomical locking plate with two cancellous screws (φ6.5 mm) and four locking screws (φ5.0 mm), the design of which is unique among posterior tension-band plates. The GWP provides reliable stability of the posterior construct of the pelvic ring and accelerates rehabilitation. Compared to alternative surgical techniques for posterior fixation, the simple surgical procedure of the GWP is minimally invasive and highly reproducible, which leads to fewer complications and less radiation exposure. Elsevier 2022-08-19 /pmc/articles/PMC9436802/ /pubmed/36061970 http://dx.doi.org/10.1016/j.jcot.2022.101991 Text en © 2022 The Authors https://creativecommons.org/licenses/by-nc-nd/4.0/This is an open access article under the CC BY-NC-ND license (http://creativecommons.org/licenses/by-nc-nd/4.0/). |
spellingShingle | Case Report Mitsuzawa, Sadaki Kusakabe, Kenji Matsuda, Shuichi Minimally invasive transiliac anatomical locking plate for posterior pelvic ring injury: A technical trick of the gull wing plate |
title | Minimally invasive transiliac anatomical locking plate for posterior pelvic ring injury: A technical trick of the gull wing plate |
title_full | Minimally invasive transiliac anatomical locking plate for posterior pelvic ring injury: A technical trick of the gull wing plate |
title_fullStr | Minimally invasive transiliac anatomical locking plate for posterior pelvic ring injury: A technical trick of the gull wing plate |
title_full_unstemmed | Minimally invasive transiliac anatomical locking plate for posterior pelvic ring injury: A technical trick of the gull wing plate |
title_short | Minimally invasive transiliac anatomical locking plate for posterior pelvic ring injury: A technical trick of the gull wing plate |
title_sort | minimally invasive transiliac anatomical locking plate for posterior pelvic ring injury: a technical trick of the gull wing plate |
topic | Case Report |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9436802/ https://www.ncbi.nlm.nih.gov/pubmed/36061970 http://dx.doi.org/10.1016/j.jcot.2022.101991 |
work_keys_str_mv | AT mitsuzawasadaki minimallyinvasivetransiliacanatomicallockingplateforposteriorpelvicringinjuryatechnicaltrickofthegullwingplate AT kusakabekenji minimallyinvasivetransiliacanatomicallockingplateforposteriorpelvicringinjuryatechnicaltrickofthegullwingplate AT matsudashuichi minimallyinvasivetransiliacanatomicallockingplateforposteriorpelvicringinjuryatechnicaltrickofthegullwingplate |