Intraoperative CT-guided navigation versus fluoroscopy for percutaneous pedicle screw placement in 192 patients: a comparative analysis

BACKGROUND: Percutaneous pedicle screw (PPS) placement is a key step in several minimally invasive spinal surgery (MISS) procedures. Traditional technique for PPS makes use of C-arm fluoroscopy assistance (FA). More recently, newer intraoperative imaging techniques have been developed for PPS, inclu...

Descripción completa

Detalles Bibliográficos
Autores principales: La Rocca, Giuseppe, Mazzucchi, Edoardo, Pignotti, Fabrizio, Nasto, Luigi Aurelio, Galieri, Gianluca, Olivi, Alessandro, De Santis, Vincenzo, Rinaldi, Pierluigi, Pola, Enrico, Sabatino, Giovanni
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Springer International Publishing 2022
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9437178/
https://www.ncbi.nlm.nih.gov/pubmed/36048284
http://dx.doi.org/10.1186/s10195-022-00661-8
_version_ 1784781527510417408
author La Rocca, Giuseppe
Mazzucchi, Edoardo
Pignotti, Fabrizio
Nasto, Luigi Aurelio
Galieri, Gianluca
Olivi, Alessandro
De Santis, Vincenzo
Rinaldi, Pierluigi
Pola, Enrico
Sabatino, Giovanni
author_facet La Rocca, Giuseppe
Mazzucchi, Edoardo
Pignotti, Fabrizio
Nasto, Luigi Aurelio
Galieri, Gianluca
Olivi, Alessandro
De Santis, Vincenzo
Rinaldi, Pierluigi
Pola, Enrico
Sabatino, Giovanni
author_sort La Rocca, Giuseppe
collection PubMed
description BACKGROUND: Percutaneous pedicle screw (PPS) placement is a key step in several minimally invasive spinal surgery (MISS) procedures. Traditional technique for PPS makes use of C-arm fluoroscopy assistance (FA). More recently, newer intraoperative imaging techniques have been developed for PPS, including CT-guided navigation (CTNav). The aim of this study was to compare FA and CTNav techniques for PPS with regard to accuracy, complications, and radiation dosage. MATERIALS AND METHODS: A total of 192 patients with degenerative lumbar spondylolisthesis and canal stenosis who underwent MISS posterior fusion ± interbody fusion through transforaminal approach (TLIF) were retrospectively reviewed. Pedicle screws were placed percutaneously using either standard C-arm fluoroscopy guidance (FA group) or CT navigation (CTNav group). Intraoperative effective dose (ED, mSv) was measured. Screw placement accuracy was assessed postoperatively on a CT scan using Gertzbein and Robbins classification (grades A–E). Oswestry disability index (ODI) and visual analog scale (VAS) scores were compared in both groups before and after surgery. RESULTS: A total of 101 and 91 procedures were performed with FA (FA group) and CTNav approach (CTNav group), respectively. Median age was 61 years in both groups, and the most commonly treated level was L4–L5. Median ED received from patients was 1.504 mSv (0.494–4.406) in FA technique and 21.130 mSv (10.840–30.390) in CTNav approach (p < 0.001). Percentage of grade A and B screws was significantly higher for the CTNav group (96.4% versus 92%, p < 0.001), whereas there were 16 grade E screws in the FA group and 0 grade E screws in the CTNav group (p < 0.001). A total of seven and five complications were reported in the FA and CTNav group, respectively (p = 0.771). CONCLUSIONS: CTNav technique increases accuracy of pedicle screw placement compared with FA technique without affecting operative time. Nevertheless, no significant difference was noted in terms of reoperation rate due to screw malpositioning between CTNav and FA techniques. Radiation exposure of patients was significantly higher with CTNav technique. Level of Evidence: Level 3.
format Online
Article
Text
id pubmed-9437178
institution National Center for Biotechnology Information
language English
publishDate 2022
publisher Springer International Publishing
record_format MEDLINE/PubMed
spelling pubmed-94371782022-09-03 Intraoperative CT-guided navigation versus fluoroscopy for percutaneous pedicle screw placement in 192 patients: a comparative analysis La Rocca, Giuseppe Mazzucchi, Edoardo Pignotti, Fabrizio Nasto, Luigi Aurelio Galieri, Gianluca Olivi, Alessandro De Santis, Vincenzo Rinaldi, Pierluigi Pola, Enrico Sabatino, Giovanni J Orthop Traumatol Original Article BACKGROUND: Percutaneous pedicle screw (PPS) placement is a key step in several minimally invasive spinal surgery (MISS) procedures. Traditional technique for PPS makes use of C-arm fluoroscopy assistance (FA). More recently, newer intraoperative imaging techniques have been developed for PPS, including CT-guided navigation (CTNav). The aim of this study was to compare FA and CTNav techniques for PPS with regard to accuracy, complications, and radiation dosage. MATERIALS AND METHODS: A total of 192 patients with degenerative lumbar spondylolisthesis and canal stenosis who underwent MISS posterior fusion ± interbody fusion through transforaminal approach (TLIF) were retrospectively reviewed. Pedicle screws were placed percutaneously using either standard C-arm fluoroscopy guidance (FA group) or CT navigation (CTNav group). Intraoperative effective dose (ED, mSv) was measured. Screw placement accuracy was assessed postoperatively on a CT scan using Gertzbein and Robbins classification (grades A–E). Oswestry disability index (ODI) and visual analog scale (VAS) scores were compared in both groups before and after surgery. RESULTS: A total of 101 and 91 procedures were performed with FA (FA group) and CTNav approach (CTNav group), respectively. Median age was 61 years in both groups, and the most commonly treated level was L4–L5. Median ED received from patients was 1.504 mSv (0.494–4.406) in FA technique and 21.130 mSv (10.840–30.390) in CTNav approach (p < 0.001). Percentage of grade A and B screws was significantly higher for the CTNav group (96.4% versus 92%, p < 0.001), whereas there were 16 grade E screws in the FA group and 0 grade E screws in the CTNav group (p < 0.001). A total of seven and five complications were reported in the FA and CTNav group, respectively (p = 0.771). CONCLUSIONS: CTNav technique increases accuracy of pedicle screw placement compared with FA technique without affecting operative time. Nevertheless, no significant difference was noted in terms of reoperation rate due to screw malpositioning between CTNav and FA techniques. Radiation exposure of patients was significantly higher with CTNav technique. Level of Evidence: Level 3. Springer International Publishing 2022-09-01 2022-12 /pmc/articles/PMC9437178/ /pubmed/36048284 http://dx.doi.org/10.1186/s10195-022-00661-8 Text en © The Author(s) 2022 https://creativecommons.org/licenses/by/4.0/Open AccessThis article is licensed under a Creative Commons Attribution 4.0 International License, which permits use, sharing, adaptation, distribution and reproduction in any medium or format, as long as you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons licence, and indicate if changes were made. The images or other third party material in this article are included in the article's Creative Commons licence, unless indicated otherwise in a credit line to the material. If material is not included in the article's Creative Commons licence and your intended use is not permitted by statutory regulation or exceeds the permitted use, you will need to obtain permission directly from the copyright holder. To view a copy of this licence, visit http://creativecommons.org/licenses/by/4.0/ (https://creativecommons.org/licenses/by/4.0/) .
spellingShingle Original Article
La Rocca, Giuseppe
Mazzucchi, Edoardo
Pignotti, Fabrizio
Nasto, Luigi Aurelio
Galieri, Gianluca
Olivi, Alessandro
De Santis, Vincenzo
Rinaldi, Pierluigi
Pola, Enrico
Sabatino, Giovanni
Intraoperative CT-guided navigation versus fluoroscopy for percutaneous pedicle screw placement in 192 patients: a comparative analysis
title Intraoperative CT-guided navigation versus fluoroscopy for percutaneous pedicle screw placement in 192 patients: a comparative analysis
title_full Intraoperative CT-guided navigation versus fluoroscopy for percutaneous pedicle screw placement in 192 patients: a comparative analysis
title_fullStr Intraoperative CT-guided navigation versus fluoroscopy for percutaneous pedicle screw placement in 192 patients: a comparative analysis
title_full_unstemmed Intraoperative CT-guided navigation versus fluoroscopy for percutaneous pedicle screw placement in 192 patients: a comparative analysis
title_short Intraoperative CT-guided navigation versus fluoroscopy for percutaneous pedicle screw placement in 192 patients: a comparative analysis
title_sort intraoperative ct-guided navigation versus fluoroscopy for percutaneous pedicle screw placement in 192 patients: a comparative analysis
topic Original Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9437178/
https://www.ncbi.nlm.nih.gov/pubmed/36048284
http://dx.doi.org/10.1186/s10195-022-00661-8
work_keys_str_mv AT laroccagiuseppe intraoperativectguidednavigationversusfluoroscopyforpercutaneouspediclescrewplacementin192patientsacomparativeanalysis
AT mazzucchiedoardo intraoperativectguidednavigationversusfluoroscopyforpercutaneouspediclescrewplacementin192patientsacomparativeanalysis
AT pignottifabrizio intraoperativectguidednavigationversusfluoroscopyforpercutaneouspediclescrewplacementin192patientsacomparativeanalysis
AT nastoluigiaurelio intraoperativectguidednavigationversusfluoroscopyforpercutaneouspediclescrewplacementin192patientsacomparativeanalysis
AT galierigianluca intraoperativectguidednavigationversusfluoroscopyforpercutaneouspediclescrewplacementin192patientsacomparativeanalysis
AT olivialessandro intraoperativectguidednavigationversusfluoroscopyforpercutaneouspediclescrewplacementin192patientsacomparativeanalysis
AT desantisvincenzo intraoperativectguidednavigationversusfluoroscopyforpercutaneouspediclescrewplacementin192patientsacomparativeanalysis
AT rinaldipierluigi intraoperativectguidednavigationversusfluoroscopyforpercutaneouspediclescrewplacementin192patientsacomparativeanalysis
AT polaenrico intraoperativectguidednavigationversusfluoroscopyforpercutaneouspediclescrewplacementin192patientsacomparativeanalysis
AT sabatinogiovanni intraoperativectguidednavigationversusfluoroscopyforpercutaneouspediclescrewplacementin192patientsacomparativeanalysis