Cargando…
The effect of Nickel hypersensitivity on the outcome of total knee arthroplasty and the value of skin patch testing: a systematic review
BACKGROUND: To assess the Nickel sensitizing potential of total knee arthroplasty (TKA), explore the relationship between hypersensitivity and clinical outcomes, and evaluate the utility of skin patch testing pre- and/or postoperatively. MATERIALS AND METHODS: A literature search was performed throu...
Autores principales: | , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
BioMed Central
2022
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9438335/ https://www.ncbi.nlm.nih.gov/pubmed/36050799 http://dx.doi.org/10.1186/s42836-022-00144-5 |
_version_ | 1784781805721747456 |
---|---|
author | Peacock, C. J. H. Fu, H. Asopa, V. Clement, N. D. Kader, D. Sochart, D. H. |
author_facet | Peacock, C. J. H. Fu, H. Asopa, V. Clement, N. D. Kader, D. Sochart, D. H. |
author_sort | Peacock, C. J. H. |
collection | PubMed |
description | BACKGROUND: To assess the Nickel sensitizing potential of total knee arthroplasty (TKA), explore the relationship between hypersensitivity and clinical outcomes, and evaluate the utility of skin patch testing pre- and/or postoperatively. MATERIALS AND METHODS: A literature search was performed through EMBASE, Medline and PubMed databases. Articles were screened independently by two investigators. The level of evidence of studies was assessed using the Oxford Centre for Evidence-Based Medicine Criteria and the quality evaluated using the Methodological Index for Non-randomized Studies and Cochrane risk-of-bias tools. RESULTS: Twenty studies met the eligibility criteria, reporting on 1354 knee arthroplasties. Studies included patients undergoing primary or revision TKA, pre- and/or postoperatively, and used patch testing to identify Nickel hypersensitivity. Prevalence of Nickel hypersensitivity ranged from 0% to 87.5%. One study compared the prevalence of Nickel hypersensitivity in the same patient group before and after surgery and noted newly positive patch test reactions in three patients (4.2%). Three studies reported lower prevalence of Nickel hypersensitivity in postoperative patients compared to preoperative ones. Seven studies suggested that hypersensitivity might cause adverse clinical outcomes, but six did not support any relationship. Seven studies recommended preoperative patch testing in patients with history of metal allergy, and nine concluded that testing may be valuable postoperatively. CONCLUSIONS: Patients undergoing TKA with no prior history of metal hypersensitivity do not seem to be at an increased risk of developing Nickel hypersensitivity, and there is conflicting evidence that patients with pre-existing hypersensitivity are more likely to experience adverse outcomes. Patch testing remains the most commonly used method for diagnosing hypersensitivity, and evidence suggests preoperative testing in patients with history of metal allergy to aid prosthesis selection, and postoperatively in patients with suspected hypersensitivity once common causes of implant failure have been excluded, since revision with hypoallergenic implants may alleviate symptoms. SUPPLEMENTARY INFORMATION: The online version contains supplementary material available at 10.1186/s42836-022-00144-5. |
format | Online Article Text |
id | pubmed-9438335 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2022 |
publisher | BioMed Central |
record_format | MEDLINE/PubMed |
spelling | pubmed-94383352022-09-03 The effect of Nickel hypersensitivity on the outcome of total knee arthroplasty and the value of skin patch testing: a systematic review Peacock, C. J. H. Fu, H. Asopa, V. Clement, N. D. Kader, D. Sochart, D. H. Arthroplasty Review BACKGROUND: To assess the Nickel sensitizing potential of total knee arthroplasty (TKA), explore the relationship between hypersensitivity and clinical outcomes, and evaluate the utility of skin patch testing pre- and/or postoperatively. MATERIALS AND METHODS: A literature search was performed through EMBASE, Medline and PubMed databases. Articles were screened independently by two investigators. The level of evidence of studies was assessed using the Oxford Centre for Evidence-Based Medicine Criteria and the quality evaluated using the Methodological Index for Non-randomized Studies and Cochrane risk-of-bias tools. RESULTS: Twenty studies met the eligibility criteria, reporting on 1354 knee arthroplasties. Studies included patients undergoing primary or revision TKA, pre- and/or postoperatively, and used patch testing to identify Nickel hypersensitivity. Prevalence of Nickel hypersensitivity ranged from 0% to 87.5%. One study compared the prevalence of Nickel hypersensitivity in the same patient group before and after surgery and noted newly positive patch test reactions in three patients (4.2%). Three studies reported lower prevalence of Nickel hypersensitivity in postoperative patients compared to preoperative ones. Seven studies suggested that hypersensitivity might cause adverse clinical outcomes, but six did not support any relationship. Seven studies recommended preoperative patch testing in patients with history of metal allergy, and nine concluded that testing may be valuable postoperatively. CONCLUSIONS: Patients undergoing TKA with no prior history of metal hypersensitivity do not seem to be at an increased risk of developing Nickel hypersensitivity, and there is conflicting evidence that patients with pre-existing hypersensitivity are more likely to experience adverse outcomes. Patch testing remains the most commonly used method for diagnosing hypersensitivity, and evidence suggests preoperative testing in patients with history of metal allergy to aid prosthesis selection, and postoperatively in patients with suspected hypersensitivity once common causes of implant failure have been excluded, since revision with hypoallergenic implants may alleviate symptoms. SUPPLEMENTARY INFORMATION: The online version contains supplementary material available at 10.1186/s42836-022-00144-5. BioMed Central 2022-09-02 /pmc/articles/PMC9438335/ /pubmed/36050799 http://dx.doi.org/10.1186/s42836-022-00144-5 Text en © The Author(s) 2022 https://creativecommons.org/licenses/by/4.0/Open AccessThis article is licensed under a Creative Commons Attribution 4.0 International License, which permits use, sharing, adaptation, distribution and reproduction in any medium or format, as long as you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons licence, and indicate if changes were made. The images or other third party material in this article are included in the article's Creative Commons licence, unless indicated otherwise in a credit line to the material. If material is not included in the article's Creative Commons licence and your intended use is not permitted by statutory regulation or exceeds the permitted use, you will need to obtain permission directly from the copyright holder. To view a copy of this licence, visit http://creativecommons.org/licenses/by/4.0/ (https://creativecommons.org/licenses/by/4.0/) . |
spellingShingle | Review Peacock, C. J. H. Fu, H. Asopa, V. Clement, N. D. Kader, D. Sochart, D. H. The effect of Nickel hypersensitivity on the outcome of total knee arthroplasty and the value of skin patch testing: a systematic review |
title | The effect of Nickel hypersensitivity on the outcome of total knee arthroplasty and the value of skin patch testing: a systematic review |
title_full | The effect of Nickel hypersensitivity on the outcome of total knee arthroplasty and the value of skin patch testing: a systematic review |
title_fullStr | The effect of Nickel hypersensitivity on the outcome of total knee arthroplasty and the value of skin patch testing: a systematic review |
title_full_unstemmed | The effect of Nickel hypersensitivity on the outcome of total knee arthroplasty and the value of skin patch testing: a systematic review |
title_short | The effect of Nickel hypersensitivity on the outcome of total knee arthroplasty and the value of skin patch testing: a systematic review |
title_sort | effect of nickel hypersensitivity on the outcome of total knee arthroplasty and the value of skin patch testing: a systematic review |
topic | Review |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9438335/ https://www.ncbi.nlm.nih.gov/pubmed/36050799 http://dx.doi.org/10.1186/s42836-022-00144-5 |
work_keys_str_mv | AT peacockcjh theeffectofnickelhypersensitivityontheoutcomeoftotalkneearthroplastyandthevalueofskinpatchtestingasystematicreview AT fuh theeffectofnickelhypersensitivityontheoutcomeoftotalkneearthroplastyandthevalueofskinpatchtestingasystematicreview AT asopav theeffectofnickelhypersensitivityontheoutcomeoftotalkneearthroplastyandthevalueofskinpatchtestingasystematicreview AT clementnd theeffectofnickelhypersensitivityontheoutcomeoftotalkneearthroplastyandthevalueofskinpatchtestingasystematicreview AT kaderd theeffectofnickelhypersensitivityontheoutcomeoftotalkneearthroplastyandthevalueofskinpatchtestingasystematicreview AT sochartdh theeffectofnickelhypersensitivityontheoutcomeoftotalkneearthroplastyandthevalueofskinpatchtestingasystematicreview AT peacockcjh effectofnickelhypersensitivityontheoutcomeoftotalkneearthroplastyandthevalueofskinpatchtestingasystematicreview AT fuh effectofnickelhypersensitivityontheoutcomeoftotalkneearthroplastyandthevalueofskinpatchtestingasystematicreview AT asopav effectofnickelhypersensitivityontheoutcomeoftotalkneearthroplastyandthevalueofskinpatchtestingasystematicreview AT clementnd effectofnickelhypersensitivityontheoutcomeoftotalkneearthroplastyandthevalueofskinpatchtestingasystematicreview AT kaderd effectofnickelhypersensitivityontheoutcomeoftotalkneearthroplastyandthevalueofskinpatchtestingasystematicreview AT sochartdh effectofnickelhypersensitivityontheoutcomeoftotalkneearthroplastyandthevalueofskinpatchtestingasystematicreview |