Application of Dual-Energy Spectral Computed Tomography in Bone Mineral Density Measurement: Phantom and Clinical Research

INTRODUCTION: Early detection and treatment of osteoporosis through bone mineral density (BMD) measurement could aid in the prevention of osteoporosis-related fractures. We aimed to assess the parameter of dual-energy spectral CT (DesCT) consistency with BMD determination using quantitative computed...

Descripción completa

Detalles Bibliográficos
Autores principales: Wang, Mingyue, Wu, Yan, Zhou, Yue, Dong, Junqiang, Hu, Shenshen, Hou, Ping, Gao, Jianbo
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Dove 2022
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9439073/
https://www.ncbi.nlm.nih.gov/pubmed/36061965
http://dx.doi.org/10.2147/IJGM.S381857
_version_ 1784781969192648704
author Wang, Mingyue
Wu, Yan
Zhou, Yue
Dong, Junqiang
Hu, Shenshen
Hou, Ping
Gao, Jianbo
author_facet Wang, Mingyue
Wu, Yan
Zhou, Yue
Dong, Junqiang
Hu, Shenshen
Hou, Ping
Gao, Jianbo
author_sort Wang, Mingyue
collection PubMed
description INTRODUCTION: Early detection and treatment of osteoporosis through bone mineral density (BMD) measurement could aid in the prevention of osteoporosis-related fractures. We aimed to assess the parameter of dual-energy spectral CT (DesCT) consistency with BMD determination using quantitative computed tomography (QCT), thereby establishing a basis for further DesCT application for BMD determination. METHODS: We subjected the European spine phantom, which contains three vertebral bodies (V1, V2, and V3), to DesCT with different radiation doses. The basis material pairs were hydroxyapatite (water), calcium (water), and hydroxyapatite (fat). Additionally, the medical records of 152 patients who underwent QCT and DesCT for chest scans in a two-month period were reviewed to measure BMD values. RESULTS: No significant differences were found in the basis pair values of the V1, V2, or V3 vertebrae under different radiation doses in the phantom; in particular, the hydroxyapatite (water), hydroxyapatite (fat), relative error values of V1, V2, and V3 under different radiation doses were not significantly different (all p > 0.05). For patients, the hydroxyapatite (water), hydroxyapatite (fat), and hydroxyapatite (average) values measured by DesCT had a significant correlation with BMD measured by QCT Among 242 vertebrae (152 T12 and 90 L1 vertebrae), there was no significant difference between the BMD measured by QCT and the HAP (average) measured by DesCT (p = 0.071). The interclass correlation coefficient (ICC) value was 0.925 between the HAP (average) and HAP (average) with DesCT and BMD measured by QCT (p < 0.001). Bland-Altman diagram indicated that both measurements were in good agreement. DISCUSSION: We showed that BMD values measured by DesCT were stable and repeatable under different radiation doses. DesCT and QCT measurements of human BMD were highly correlated. Thus, DesCT-based BMD assessment of the spine in a clinical setting could be considered feasible.
format Online
Article
Text
id pubmed-9439073
institution National Center for Biotechnology Information
language English
publishDate 2022
publisher Dove
record_format MEDLINE/PubMed
spelling pubmed-94390732022-09-03 Application of Dual-Energy Spectral Computed Tomography in Bone Mineral Density Measurement: Phantom and Clinical Research Wang, Mingyue Wu, Yan Zhou, Yue Dong, Junqiang Hu, Shenshen Hou, Ping Gao, Jianbo Int J Gen Med Original Research INTRODUCTION: Early detection and treatment of osteoporosis through bone mineral density (BMD) measurement could aid in the prevention of osteoporosis-related fractures. We aimed to assess the parameter of dual-energy spectral CT (DesCT) consistency with BMD determination using quantitative computed tomography (QCT), thereby establishing a basis for further DesCT application for BMD determination. METHODS: We subjected the European spine phantom, which contains three vertebral bodies (V1, V2, and V3), to DesCT with different radiation doses. The basis material pairs were hydroxyapatite (water), calcium (water), and hydroxyapatite (fat). Additionally, the medical records of 152 patients who underwent QCT and DesCT for chest scans in a two-month period were reviewed to measure BMD values. RESULTS: No significant differences were found in the basis pair values of the V1, V2, or V3 vertebrae under different radiation doses in the phantom; in particular, the hydroxyapatite (water), hydroxyapatite (fat), relative error values of V1, V2, and V3 under different radiation doses were not significantly different (all p > 0.05). For patients, the hydroxyapatite (water), hydroxyapatite (fat), and hydroxyapatite (average) values measured by DesCT had a significant correlation with BMD measured by QCT Among 242 vertebrae (152 T12 and 90 L1 vertebrae), there was no significant difference between the BMD measured by QCT and the HAP (average) measured by DesCT (p = 0.071). The interclass correlation coefficient (ICC) value was 0.925 between the HAP (average) and HAP (average) with DesCT and BMD measured by QCT (p < 0.001). Bland-Altman diagram indicated that both measurements were in good agreement. DISCUSSION: We showed that BMD values measured by DesCT were stable and repeatable under different radiation doses. DesCT and QCT measurements of human BMD were highly correlated. Thus, DesCT-based BMD assessment of the spine in a clinical setting could be considered feasible. Dove 2022-08-29 /pmc/articles/PMC9439073/ /pubmed/36061965 http://dx.doi.org/10.2147/IJGM.S381857 Text en © 2022 Wang et al. https://creativecommons.org/licenses/by-nc/3.0/This work is published and licensed by Dove Medical Press Limited. The full terms of this license are available at https://www.dovepress.com/terms.php and incorporate the Creative Commons Attribution – Non Commercial (unported, v3.0) License (http://creativecommons.org/licenses/by-nc/3.0/ (https://creativecommons.org/licenses/by-nc/3.0/) ). By accessing the work you hereby accept the Terms. Non-commercial uses of the work are permitted without any further permission from Dove Medical Press Limited, provided the work is properly attributed. For permission for commercial use of this work, please see paragraphs 4.2 and 5 of our Terms (https://www.dovepress.com/terms.php).
spellingShingle Original Research
Wang, Mingyue
Wu, Yan
Zhou, Yue
Dong, Junqiang
Hu, Shenshen
Hou, Ping
Gao, Jianbo
Application of Dual-Energy Spectral Computed Tomography in Bone Mineral Density Measurement: Phantom and Clinical Research
title Application of Dual-Energy Spectral Computed Tomography in Bone Mineral Density Measurement: Phantom and Clinical Research
title_full Application of Dual-Energy Spectral Computed Tomography in Bone Mineral Density Measurement: Phantom and Clinical Research
title_fullStr Application of Dual-Energy Spectral Computed Tomography in Bone Mineral Density Measurement: Phantom and Clinical Research
title_full_unstemmed Application of Dual-Energy Spectral Computed Tomography in Bone Mineral Density Measurement: Phantom and Clinical Research
title_short Application of Dual-Energy Spectral Computed Tomography in Bone Mineral Density Measurement: Phantom and Clinical Research
title_sort application of dual-energy spectral computed tomography in bone mineral density measurement: phantom and clinical research
topic Original Research
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9439073/
https://www.ncbi.nlm.nih.gov/pubmed/36061965
http://dx.doi.org/10.2147/IJGM.S381857
work_keys_str_mv AT wangmingyue applicationofdualenergyspectralcomputedtomographyinbonemineraldensitymeasurementphantomandclinicalresearch
AT wuyan applicationofdualenergyspectralcomputedtomographyinbonemineraldensitymeasurementphantomandclinicalresearch
AT zhouyue applicationofdualenergyspectralcomputedtomographyinbonemineraldensitymeasurementphantomandclinicalresearch
AT dongjunqiang applicationofdualenergyspectralcomputedtomographyinbonemineraldensitymeasurementphantomandclinicalresearch
AT hushenshen applicationofdualenergyspectralcomputedtomographyinbonemineraldensitymeasurementphantomandclinicalresearch
AT houping applicationofdualenergyspectralcomputedtomographyinbonemineraldensitymeasurementphantomandclinicalresearch
AT gaojianbo applicationofdualenergyspectralcomputedtomographyinbonemineraldensitymeasurementphantomandclinicalresearch