Cargando…

Effects on venous flow of transcutaneous electrical stimulation, neuromuscular stimulation, and sham stimulation on soleus muscle: A randomized crossover study in healthy subjects

Activation of venous flow has been shown with different types of electrical stimulation. The aim of this study is to compare the hemodynamic effects of transcutaneous electrical nerve stimulation (TENS), neuromuscular electrical stimulation (NMES), and sham stimulation on healthy young people. METHO...

Descripción completa

Detalles Bibliográficos
Autores principales: Senin-Camargo, Francisco, Martínez-Rodríguez, Alicia, Chouza-Insua, Marcelo, Raposo-Vidal, Isabel, Jácome, M. Amalia
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Lippincott Williams & Wilkins 2022
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9439730/
https://www.ncbi.nlm.nih.gov/pubmed/36107611
http://dx.doi.org/10.1097/MD.0000000000030121
_version_ 1784782135233609728
author Senin-Camargo, Francisco
Martínez-Rodríguez, Alicia
Chouza-Insua, Marcelo
Raposo-Vidal, Isabel
Jácome, M. Amalia
author_facet Senin-Camargo, Francisco
Martínez-Rodríguez, Alicia
Chouza-Insua, Marcelo
Raposo-Vidal, Isabel
Jácome, M. Amalia
author_sort Senin-Camargo, Francisco
collection PubMed
description Activation of venous flow has been shown with different types of electrical stimulation. The aim of this study is to compare the hemodynamic effects of transcutaneous electrical nerve stimulation (TENS), neuromuscular electrical stimulation (NMES), and sham stimulation on healthy young people. METHODS: This randomized crossover study was conducted during June 2018 in the Faculty of Physical Therapy of A Coruña (Spain). Twenty-four university students (50% male) received in a randomized order 5 Hz-TENS, NMES, and sham stimulation on soleus muscle. Flow volume (FV) and peak velocity (PV) from popliteal vein were recorded via Doppler ultrasound, and relative changes from baseline were determined. Discomfort among the 3 stimulations was also compared. RESULTS: The differences among the 3 stimulations were assessed using the ANOVA for repeated measured, the Friedman test and the Kendall tau test, according to the type of measurement to be compared. FV (mL/min) and PV (cm/s) increased significantly after NMES (percentual increase 37.2 ± 62.0%, P = .002; 264.4 ± 152.2%, P < .001, respectively) and TENS (226.2 ± 190.3%, P < .001; 202.7 ± 144.6%, P < .001, respectively). These percentual changes from basal level in hemodynamics were statistically different to those after placebo, which was ineffective enhancing hemodynamics. The improvements in FV were statistically higher with TENS than with NMES (P < .001), but there was no statistical difference in PV (P = .531). Despite NMES was applied at a significantly lower amplitude than TENS (P < .001), NMES protocol was the worst tolerated, though the differences in discomfort were not statistically significant. CONCLUSION: Both active electrical protocols but not sham stimulation increased hemodynamics in healthy people. TENS obtained higher flow volume increase from baseline than NMES, considered globally at not only in its on-time.
format Online
Article
Text
id pubmed-9439730
institution National Center for Biotechnology Information
language English
publishDate 2022
publisher Lippincott Williams & Wilkins
record_format MEDLINE/PubMed
spelling pubmed-94397302022-09-06 Effects on venous flow of transcutaneous electrical stimulation, neuromuscular stimulation, and sham stimulation on soleus muscle: A randomized crossover study in healthy subjects Senin-Camargo, Francisco Martínez-Rodríguez, Alicia Chouza-Insua, Marcelo Raposo-Vidal, Isabel Jácome, M. Amalia Medicine (Baltimore) Research Article Activation of venous flow has been shown with different types of electrical stimulation. The aim of this study is to compare the hemodynamic effects of transcutaneous electrical nerve stimulation (TENS), neuromuscular electrical stimulation (NMES), and sham stimulation on healthy young people. METHODS: This randomized crossover study was conducted during June 2018 in the Faculty of Physical Therapy of A Coruña (Spain). Twenty-four university students (50% male) received in a randomized order 5 Hz-TENS, NMES, and sham stimulation on soleus muscle. Flow volume (FV) and peak velocity (PV) from popliteal vein were recorded via Doppler ultrasound, and relative changes from baseline were determined. Discomfort among the 3 stimulations was also compared. RESULTS: The differences among the 3 stimulations were assessed using the ANOVA for repeated measured, the Friedman test and the Kendall tau test, according to the type of measurement to be compared. FV (mL/min) and PV (cm/s) increased significantly after NMES (percentual increase 37.2 ± 62.0%, P = .002; 264.4 ± 152.2%, P < .001, respectively) and TENS (226.2 ± 190.3%, P < .001; 202.7 ± 144.6%, P < .001, respectively). These percentual changes from basal level in hemodynamics were statistically different to those after placebo, which was ineffective enhancing hemodynamics. The improvements in FV were statistically higher with TENS than with NMES (P < .001), but there was no statistical difference in PV (P = .531). Despite NMES was applied at a significantly lower amplitude than TENS (P < .001), NMES protocol was the worst tolerated, though the differences in discomfort were not statistically significant. CONCLUSION: Both active electrical protocols but not sham stimulation increased hemodynamics in healthy people. TENS obtained higher flow volume increase from baseline than NMES, considered globally at not only in its on-time. Lippincott Williams & Wilkins 2022-09-02 /pmc/articles/PMC9439730/ /pubmed/36107611 http://dx.doi.org/10.1097/MD.0000000000030121 Text en Copyright © 2022 the Author(s). Published by Wolters Kluwer Health, Inc. https://creativecommons.org/licenses/by-nc/4.0/This is an open-access article distributed under the terms of the Creative Commons Attribution-Non Commercial License 4.0 (CCBY-NC) (https://creativecommons.org/licenses/by-nc/4.0/) , where it is permissible to download, share, remix, transform, and buildup the work provided it is properly cited. The work cannot be used commercially without permission from the journal.
spellingShingle Research Article
Senin-Camargo, Francisco
Martínez-Rodríguez, Alicia
Chouza-Insua, Marcelo
Raposo-Vidal, Isabel
Jácome, M. Amalia
Effects on venous flow of transcutaneous electrical stimulation, neuromuscular stimulation, and sham stimulation on soleus muscle: A randomized crossover study in healthy subjects
title Effects on venous flow of transcutaneous electrical stimulation, neuromuscular stimulation, and sham stimulation on soleus muscle: A randomized crossover study in healthy subjects
title_full Effects on venous flow of transcutaneous electrical stimulation, neuromuscular stimulation, and sham stimulation on soleus muscle: A randomized crossover study in healthy subjects
title_fullStr Effects on venous flow of transcutaneous electrical stimulation, neuromuscular stimulation, and sham stimulation on soleus muscle: A randomized crossover study in healthy subjects
title_full_unstemmed Effects on venous flow of transcutaneous electrical stimulation, neuromuscular stimulation, and sham stimulation on soleus muscle: A randomized crossover study in healthy subjects
title_short Effects on venous flow of transcutaneous electrical stimulation, neuromuscular stimulation, and sham stimulation on soleus muscle: A randomized crossover study in healthy subjects
title_sort effects on venous flow of transcutaneous electrical stimulation, neuromuscular stimulation, and sham stimulation on soleus muscle: a randomized crossover study in healthy subjects
topic Research Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9439730/
https://www.ncbi.nlm.nih.gov/pubmed/36107611
http://dx.doi.org/10.1097/MD.0000000000030121
work_keys_str_mv AT senincamargofrancisco effectsonvenousflowoftranscutaneouselectricalstimulationneuromuscularstimulationandshamstimulationonsoleusmusclearandomizedcrossoverstudyinhealthysubjects
AT martinezrodriguezalicia effectsonvenousflowoftranscutaneouselectricalstimulationneuromuscularstimulationandshamstimulationonsoleusmusclearandomizedcrossoverstudyinhealthysubjects
AT chouzainsuamarcelo effectsonvenousflowoftranscutaneouselectricalstimulationneuromuscularstimulationandshamstimulationonsoleusmusclearandomizedcrossoverstudyinhealthysubjects
AT raposovidalisabel effectsonvenousflowoftranscutaneouselectricalstimulationneuromuscularstimulationandshamstimulationonsoleusmusclearandomizedcrossoverstudyinhealthysubjects
AT jacomemamalia effectsonvenousflowoftranscutaneouselectricalstimulationneuromuscularstimulationandshamstimulationonsoleusmusclearandomizedcrossoverstudyinhealthysubjects