Cargando…

Accuracy of Magnetic Resonance Imaging in Diagnosing Placenta Accreta: A Systematic Review and Meta-Analysis

BACKGROUND: The disease burden and incidence of placenta accreta are increasing worldwide. The morbidity and mortality associated with undiagnosed placenta accreta are both high, highlighting the important of early diagnosis and intervention. In recent years, increasing studies are exploring the dia...

Descripción completa

Detalles Bibliográficos
Autores principales: Lin, Huien, Li, Li, Lin, Yi, Wang, Wenhuan
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Hindawi 2022
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9439908/
https://www.ncbi.nlm.nih.gov/pubmed/36060665
http://dx.doi.org/10.1155/2022/2751559
_version_ 1784782188662751232
author Lin, Huien
Li, Li
Lin, Yi
Wang, Wenhuan
author_facet Lin, Huien
Li, Li
Lin, Yi
Wang, Wenhuan
author_sort Lin, Huien
collection PubMed
description BACKGROUND: The disease burden and incidence of placenta accreta are increasing worldwide. The morbidity and mortality associated with undiagnosed placenta accreta are both high, highlighting the important of early diagnosis and intervention. In recent years, increasing studies are exploring the diagnostic value of magnetic resonance imaging (MRI) for placenta accreta. Compared with traditional ultrasound, MRI has the advantages of high-resolution, multiangle imaging, and less influence by amniotic fluid and intestinal gas. However, the reported diagnostic accuracy among studies was inconsistent. Therefore, this study is aimed at exploring the diagnostic value of MRI for placenta accreta by systematic review and meta-analysis. METHODS: Relevant literature were systematically searched in PubMed, Ovid, Embase, ScienceDirect database, CNKI, and Wanfang database by using medical subject headings and relevant diagnostic terminologies such as sensitivity, specificity, likelihood ratio, receiver-operating characteristic curve, and area under the curve. The sensitivity, specificity, positive likelihood ratio, negative likelihood ratio, and area under the curve of the included literature were analyzed using stata 17.0 software. Publication bias of the included studies was assessed by Deek's funnel plot. Cochrane Q statistics and I(2) statistics were used to test the heterogeneity. RESULTS: A total of 10 primary publications, comprising 4 retrospective studies and 6 prospective studies, were included in this meta-analysis. The gestational weeks of pregnant women ranged from 32 to 35 weeks, and the sample size ranged from 37 cases to 575 cases. Only 4 studies used the blind method in the process of clinical diagnosis by MRI. The combined sensitivity, specificity, and area of curve under summary receiver-operating characteristic for the diagnosis of placenta accreta by MRI were 0.88 (95% CI, 0.79-0.93), 0.79 (95% CI, 0.68-0.87), and 0.91 (95% CI, 0.88.-0.93), respectively. The combined positive likelihood ratio, negative likelihood ratio, diagnostic odds ratio, and diagnostic score were 4.17 (95% CI, 2.62-6.66), 0.16 (95% CI, 0.09-0.29), 26.61 (95% CI, 10.22-69.28), and 3.28 (95% CI, 2.32-4.24), respectively. No publication bias was noted. CONCLUSION: Diagnosis of placenta accreta by MRI has good accuracy and predictive value that warrants clinical promotion.
format Online
Article
Text
id pubmed-9439908
institution National Center for Biotechnology Information
language English
publishDate 2022
publisher Hindawi
record_format MEDLINE/PubMed
spelling pubmed-94399082022-09-03 Accuracy of Magnetic Resonance Imaging in Diagnosing Placenta Accreta: A Systematic Review and Meta-Analysis Lin, Huien Li, Li Lin, Yi Wang, Wenhuan Comput Math Methods Med Research Article BACKGROUND: The disease burden and incidence of placenta accreta are increasing worldwide. The morbidity and mortality associated with undiagnosed placenta accreta are both high, highlighting the important of early diagnosis and intervention. In recent years, increasing studies are exploring the diagnostic value of magnetic resonance imaging (MRI) for placenta accreta. Compared with traditional ultrasound, MRI has the advantages of high-resolution, multiangle imaging, and less influence by amniotic fluid and intestinal gas. However, the reported diagnostic accuracy among studies was inconsistent. Therefore, this study is aimed at exploring the diagnostic value of MRI for placenta accreta by systematic review and meta-analysis. METHODS: Relevant literature were systematically searched in PubMed, Ovid, Embase, ScienceDirect database, CNKI, and Wanfang database by using medical subject headings and relevant diagnostic terminologies such as sensitivity, specificity, likelihood ratio, receiver-operating characteristic curve, and area under the curve. The sensitivity, specificity, positive likelihood ratio, negative likelihood ratio, and area under the curve of the included literature were analyzed using stata 17.0 software. Publication bias of the included studies was assessed by Deek's funnel plot. Cochrane Q statistics and I(2) statistics were used to test the heterogeneity. RESULTS: A total of 10 primary publications, comprising 4 retrospective studies and 6 prospective studies, were included in this meta-analysis. The gestational weeks of pregnant women ranged from 32 to 35 weeks, and the sample size ranged from 37 cases to 575 cases. Only 4 studies used the blind method in the process of clinical diagnosis by MRI. The combined sensitivity, specificity, and area of curve under summary receiver-operating characteristic for the diagnosis of placenta accreta by MRI were 0.88 (95% CI, 0.79-0.93), 0.79 (95% CI, 0.68-0.87), and 0.91 (95% CI, 0.88.-0.93), respectively. The combined positive likelihood ratio, negative likelihood ratio, diagnostic odds ratio, and diagnostic score were 4.17 (95% CI, 2.62-6.66), 0.16 (95% CI, 0.09-0.29), 26.61 (95% CI, 10.22-69.28), and 3.28 (95% CI, 2.32-4.24), respectively. No publication bias was noted. CONCLUSION: Diagnosis of placenta accreta by MRI has good accuracy and predictive value that warrants clinical promotion. Hindawi 2022-08-26 /pmc/articles/PMC9439908/ /pubmed/36060665 http://dx.doi.org/10.1155/2022/2751559 Text en Copyright © 2022 Huien Lin et al. https://creativecommons.org/licenses/by/4.0/This is an open access article distributed under the Creative Commons Attribution License, which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited.
spellingShingle Research Article
Lin, Huien
Li, Li
Lin, Yi
Wang, Wenhuan
Accuracy of Magnetic Resonance Imaging in Diagnosing Placenta Accreta: A Systematic Review and Meta-Analysis
title Accuracy of Magnetic Resonance Imaging in Diagnosing Placenta Accreta: A Systematic Review and Meta-Analysis
title_full Accuracy of Magnetic Resonance Imaging in Diagnosing Placenta Accreta: A Systematic Review and Meta-Analysis
title_fullStr Accuracy of Magnetic Resonance Imaging in Diagnosing Placenta Accreta: A Systematic Review and Meta-Analysis
title_full_unstemmed Accuracy of Magnetic Resonance Imaging in Diagnosing Placenta Accreta: A Systematic Review and Meta-Analysis
title_short Accuracy of Magnetic Resonance Imaging in Diagnosing Placenta Accreta: A Systematic Review and Meta-Analysis
title_sort accuracy of magnetic resonance imaging in diagnosing placenta accreta: a systematic review and meta-analysis
topic Research Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9439908/
https://www.ncbi.nlm.nih.gov/pubmed/36060665
http://dx.doi.org/10.1155/2022/2751559
work_keys_str_mv AT linhuien accuracyofmagneticresonanceimagingindiagnosingplacentaaccretaasystematicreviewandmetaanalysis
AT lili accuracyofmagneticresonanceimagingindiagnosingplacentaaccretaasystematicreviewandmetaanalysis
AT linyi accuracyofmagneticresonanceimagingindiagnosingplacentaaccretaasystematicreviewandmetaanalysis
AT wangwenhuan accuracyofmagneticresonanceimagingindiagnosingplacentaaccretaasystematicreviewandmetaanalysis