Cargando…

A preliminary study on fetal cardiac morphology and systolic function of normal and anemic pregnant women by fetal heart quantification technology

BACKGROUND: Maternal anemia is a common nutritional problem during pregnancy. Fetal heart quantification (fetal HQ) technology is used to quantitatively evaluate the size, shape, and contractile function of the fetal heart, which can reflect the development of the fetus in the uterus. METHODS: We us...

Descripción completa

Detalles Bibliográficos
Autores principales: Shen, Yuqin, Tan, Fang, Yang, Jiaojiao, Fan, Sihan, Zhang, Lianxiang, Ji, Xueqin
Formato: Online Artículo Texto
Lenguaje:English
Publicado: AME Publishing Company 2022
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9442210/
https://www.ncbi.nlm.nih.gov/pubmed/36072538
http://dx.doi.org/10.21037/tp-22-315
_version_ 1784782761031106560
author Shen, Yuqin
Tan, Fang
Yang, Jiaojiao
Fan, Sihan
Zhang, Lianxiang
Ji, Xueqin
author_facet Shen, Yuqin
Tan, Fang
Yang, Jiaojiao
Fan, Sihan
Zhang, Lianxiang
Ji, Xueqin
author_sort Shen, Yuqin
collection PubMed
description BACKGROUND: Maternal anemia is a common nutritional problem during pregnancy. Fetal heart quantification (fetal HQ) technology is used to quantitatively evaluate the size, shape, and contractile function of the fetal heart, which can reflect the development of the fetus in the uterus. METHODS: We used fetal HQ technology to evaluate the basal-apical length (BAL), the transverse width (TW) and the area (A) of the four chamber view at end-diastole in 77 normal fetuses and 40 fetuses of women with anemia. We analyzed the changes of fetal heart size and measured the global sphericity index (GSI), the fraction area change (FAC), and the global longitudinal strain (GLS). The sphericity index (SI) and the fractional shortening (FS) of 24 segments were analyzed to identify any changes of fetal heart morphology and systolic function. The normal range of Z value was set at −2 to 2. RESULTS: Fetal BAL, TW, A, and gestational age (GA) were positively linearly correlated, while GSI, GLS, and FAC had no significant correlation with GA. There was no significant difference in fetal BAL, TW, A, GLS, and FAC between the two groups (P>0.05). There was no significant difference in the FS of the 24 segments of the left and right ventricles between the two groups (P>0.05). There was no significant difference in the SI of the 1-24 segments of the right ventricle between the two groups (P>0.05). The difference in fetal GSI between the two groups was statistically significant (P<0.05). There was no significant difference in SI between the 1–22 segments of the left ventricle between the two groups (P>0.05), but there was a statistically significant difference between the 23–24 segments (P<0.05). CONCLUSIONS: The fetal HQ analysis technology can quickly and simply quantitatively assess the size, shape, and contractility of the fetal heart. Anemia in pregnant women has no significant effect on fetal heart size and systolic function; it only affects the morphology of the heart, showing that the heart tends to be spherical as a whole and some segments of the apical segment of the left ventricle are abnormal.
format Online
Article
Text
id pubmed-9442210
institution National Center for Biotechnology Information
language English
publishDate 2022
publisher AME Publishing Company
record_format MEDLINE/PubMed
spelling pubmed-94422102022-09-06 A preliminary study on fetal cardiac morphology and systolic function of normal and anemic pregnant women by fetal heart quantification technology Shen, Yuqin Tan, Fang Yang, Jiaojiao Fan, Sihan Zhang, Lianxiang Ji, Xueqin Transl Pediatr Original Article BACKGROUND: Maternal anemia is a common nutritional problem during pregnancy. Fetal heart quantification (fetal HQ) technology is used to quantitatively evaluate the size, shape, and contractile function of the fetal heart, which can reflect the development of the fetus in the uterus. METHODS: We used fetal HQ technology to evaluate the basal-apical length (BAL), the transverse width (TW) and the area (A) of the four chamber view at end-diastole in 77 normal fetuses and 40 fetuses of women with anemia. We analyzed the changes of fetal heart size and measured the global sphericity index (GSI), the fraction area change (FAC), and the global longitudinal strain (GLS). The sphericity index (SI) and the fractional shortening (FS) of 24 segments were analyzed to identify any changes of fetal heart morphology and systolic function. The normal range of Z value was set at −2 to 2. RESULTS: Fetal BAL, TW, A, and gestational age (GA) were positively linearly correlated, while GSI, GLS, and FAC had no significant correlation with GA. There was no significant difference in fetal BAL, TW, A, GLS, and FAC between the two groups (P>0.05). There was no significant difference in the FS of the 24 segments of the left and right ventricles between the two groups (P>0.05). There was no significant difference in the SI of the 1-24 segments of the right ventricle between the two groups (P>0.05). The difference in fetal GSI between the two groups was statistically significant (P<0.05). There was no significant difference in SI between the 1–22 segments of the left ventricle between the two groups (P>0.05), but there was a statistically significant difference between the 23–24 segments (P<0.05). CONCLUSIONS: The fetal HQ analysis technology can quickly and simply quantitatively assess the size, shape, and contractility of the fetal heart. Anemia in pregnant women has no significant effect on fetal heart size and systolic function; it only affects the morphology of the heart, showing that the heart tends to be spherical as a whole and some segments of the apical segment of the left ventricle are abnormal. AME Publishing Company 2022-08 /pmc/articles/PMC9442210/ /pubmed/36072538 http://dx.doi.org/10.21037/tp-22-315 Text en 2022 Translational Pediatrics. All rights reserved. https://creativecommons.org/licenses/by-nc-nd/4.0/Open Access Statement: This is an Open Access article distributed in accordance with the Creative Commons Attribution-NonCommercial-NoDerivs 4.0 International License (CC BY-NC-ND 4.0), which permits the non-commercial replication and distribution of the article with the strict proviso that no changes or edits are made and the original work is properly cited (including links to both the formal publication through the relevant DOI and the license). See: https://creativecommons.org/licenses/by-nc-nd/4.0 (https://creativecommons.org/licenses/by-nc-nd/4.0/) .
spellingShingle Original Article
Shen, Yuqin
Tan, Fang
Yang, Jiaojiao
Fan, Sihan
Zhang, Lianxiang
Ji, Xueqin
A preliminary study on fetal cardiac morphology and systolic function of normal and anemic pregnant women by fetal heart quantification technology
title A preliminary study on fetal cardiac morphology and systolic function of normal and anemic pregnant women by fetal heart quantification technology
title_full A preliminary study on fetal cardiac morphology and systolic function of normal and anemic pregnant women by fetal heart quantification technology
title_fullStr A preliminary study on fetal cardiac morphology and systolic function of normal and anemic pregnant women by fetal heart quantification technology
title_full_unstemmed A preliminary study on fetal cardiac morphology and systolic function of normal and anemic pregnant women by fetal heart quantification technology
title_short A preliminary study on fetal cardiac morphology and systolic function of normal and anemic pregnant women by fetal heart quantification technology
title_sort preliminary study on fetal cardiac morphology and systolic function of normal and anemic pregnant women by fetal heart quantification technology
topic Original Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9442210/
https://www.ncbi.nlm.nih.gov/pubmed/36072538
http://dx.doi.org/10.21037/tp-22-315
work_keys_str_mv AT shenyuqin apreliminarystudyonfetalcardiacmorphologyandsystolicfunctionofnormalandanemicpregnantwomenbyfetalheartquantificationtechnology
AT tanfang apreliminarystudyonfetalcardiacmorphologyandsystolicfunctionofnormalandanemicpregnantwomenbyfetalheartquantificationtechnology
AT yangjiaojiao apreliminarystudyonfetalcardiacmorphologyandsystolicfunctionofnormalandanemicpregnantwomenbyfetalheartquantificationtechnology
AT fansihan apreliminarystudyonfetalcardiacmorphologyandsystolicfunctionofnormalandanemicpregnantwomenbyfetalheartquantificationtechnology
AT zhanglianxiang apreliminarystudyonfetalcardiacmorphologyandsystolicfunctionofnormalandanemicpregnantwomenbyfetalheartquantificationtechnology
AT jixueqin apreliminarystudyonfetalcardiacmorphologyandsystolicfunctionofnormalandanemicpregnantwomenbyfetalheartquantificationtechnology
AT shenyuqin preliminarystudyonfetalcardiacmorphologyandsystolicfunctionofnormalandanemicpregnantwomenbyfetalheartquantificationtechnology
AT tanfang preliminarystudyonfetalcardiacmorphologyandsystolicfunctionofnormalandanemicpregnantwomenbyfetalheartquantificationtechnology
AT yangjiaojiao preliminarystudyonfetalcardiacmorphologyandsystolicfunctionofnormalandanemicpregnantwomenbyfetalheartquantificationtechnology
AT fansihan preliminarystudyonfetalcardiacmorphologyandsystolicfunctionofnormalandanemicpregnantwomenbyfetalheartquantificationtechnology
AT zhanglianxiang preliminarystudyonfetalcardiacmorphologyandsystolicfunctionofnormalandanemicpregnantwomenbyfetalheartquantificationtechnology
AT jixueqin preliminarystudyonfetalcardiacmorphologyandsystolicfunctionofnormalandanemicpregnantwomenbyfetalheartquantificationtechnology