Cargando…

Assessment of hearing threshold in adults with hearing loss using an automated system of cortical auditory evoked potential detection()

INTRODUCTION: The use of hearing aids by individuals with hearing loss brings a better quality of life. Access to and benefit from these devices may be compromised in patients who present difficulties or limitations in traditional behavioral audiological evaluation, such as newborns and small childr...

Descripción completa

Detalles Bibliográficos
Autores principales: Durante, Alessandra Spada, Wieselberg, Margarita Bernal, Roque, Nayara, Carvalho, Sheila, Pucci, Beatriz, Gudayol, Nicolly, de Almeida, Kátia
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Elsevier 2016
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9442746/
https://www.ncbi.nlm.nih.gov/pubmed/27229658
http://dx.doi.org/10.1016/j.bjorl.2016.02.016
_version_ 1784782888957378560
author Durante, Alessandra Spada
Wieselberg, Margarita Bernal
Roque, Nayara
Carvalho, Sheila
Pucci, Beatriz
Gudayol, Nicolly
de Almeida, Kátia
author_facet Durante, Alessandra Spada
Wieselberg, Margarita Bernal
Roque, Nayara
Carvalho, Sheila
Pucci, Beatriz
Gudayol, Nicolly
de Almeida, Kátia
author_sort Durante, Alessandra Spada
collection PubMed
description INTRODUCTION: The use of hearing aids by individuals with hearing loss brings a better quality of life. Access to and benefit from these devices may be compromised in patients who present difficulties or limitations in traditional behavioral audiological evaluation, such as newborns and small children, individuals with auditory neuropathy spectrum, autism, and intellectual deficits, and in adults and the elderly with dementia. These populations (or individuals) are unable to undergo a behavioral assessment, and generate a growing demand for objective methods to assess hearing. Cortical auditory evoked potentials have been used for decades to estimate hearing thresholds. Current technological advances have lead to the development of equipment that allows their clinical use, with features that enable greater accuracy, sensitivity, and specificity, and the possibility of automated detection, analysis, and recording of cortical responses. OBJECTIVE: To determine and correlate behavioral auditory thresholds with cortical auditory thresholds obtained from an automated response analysis technique. METHODS: The study included 52 adults, divided into two groups: 21 adults with moderate to severe hearing loss (study group); and 31 adults with normal hearing (control group). An automated system of detection, analysis, and recording of cortical responses (HEARLab(®)) was used to record the behavioral and cortical thresholds. The subjects remained awake in an acoustically treated environment. Altogether, 150 tone bursts at 500, 1000, 2000, and 4000 Hz were presented through insert earphones in descending-ascending intensity. The lowest level at which the subject detected the sound stimulus was defined as the behavioral (hearing) threshold (BT). The lowest level at which a cortical response was observed was defined as the cortical electrophysiological threshold. These two responses were correlated using linear regression. RESULTS: The cortical electrophysiological threshold was, on average, 7.8 dB higher than the behavioral for the group with hearing loss and, on average, 14.5 dB higher for the group without hearing loss for all studied frequencies. CONCLUSION: The cortical electrophysiological thresholds obtained with the use of an automated response detection system were highly correlated with behavioral thresholds in the group of individuals with hearing loss.
format Online
Article
Text
id pubmed-9442746
institution National Center for Biotechnology Information
language English
publishDate 2016
publisher Elsevier
record_format MEDLINE/PubMed
spelling pubmed-94427462022-09-09 Assessment of hearing threshold in adults with hearing loss using an automated system of cortical auditory evoked potential detection() Durante, Alessandra Spada Wieselberg, Margarita Bernal Roque, Nayara Carvalho, Sheila Pucci, Beatriz Gudayol, Nicolly de Almeida, Kátia Braz J Otorhinolaryngol Original Article INTRODUCTION: The use of hearing aids by individuals with hearing loss brings a better quality of life. Access to and benefit from these devices may be compromised in patients who present difficulties or limitations in traditional behavioral audiological evaluation, such as newborns and small children, individuals with auditory neuropathy spectrum, autism, and intellectual deficits, and in adults and the elderly with dementia. These populations (or individuals) are unable to undergo a behavioral assessment, and generate a growing demand for objective methods to assess hearing. Cortical auditory evoked potentials have been used for decades to estimate hearing thresholds. Current technological advances have lead to the development of equipment that allows their clinical use, with features that enable greater accuracy, sensitivity, and specificity, and the possibility of automated detection, analysis, and recording of cortical responses. OBJECTIVE: To determine and correlate behavioral auditory thresholds with cortical auditory thresholds obtained from an automated response analysis technique. METHODS: The study included 52 adults, divided into two groups: 21 adults with moderate to severe hearing loss (study group); and 31 adults with normal hearing (control group). An automated system of detection, analysis, and recording of cortical responses (HEARLab(®)) was used to record the behavioral and cortical thresholds. The subjects remained awake in an acoustically treated environment. Altogether, 150 tone bursts at 500, 1000, 2000, and 4000 Hz were presented through insert earphones in descending-ascending intensity. The lowest level at which the subject detected the sound stimulus was defined as the behavioral (hearing) threshold (BT). The lowest level at which a cortical response was observed was defined as the cortical electrophysiological threshold. These two responses were correlated using linear regression. RESULTS: The cortical electrophysiological threshold was, on average, 7.8 dB higher than the behavioral for the group with hearing loss and, on average, 14.5 dB higher for the group without hearing loss for all studied frequencies. CONCLUSION: The cortical electrophysiological thresholds obtained with the use of an automated response detection system were highly correlated with behavioral thresholds in the group of individuals with hearing loss. Elsevier 2016-04-29 /pmc/articles/PMC9442746/ /pubmed/27229658 http://dx.doi.org/10.1016/j.bjorl.2016.02.016 Text en © 2016 Associação Brasileira de Otorrinolaringologia e Cirurgia Cérvico-Facial. Published by Elsevier Editora Ltda. https://creativecommons.org/licenses/by/4.0/This is an open access article under the CC BY license (http://creativecommons.org/licenses/by/4.0/).
spellingShingle Original Article
Durante, Alessandra Spada
Wieselberg, Margarita Bernal
Roque, Nayara
Carvalho, Sheila
Pucci, Beatriz
Gudayol, Nicolly
de Almeida, Kátia
Assessment of hearing threshold in adults with hearing loss using an automated system of cortical auditory evoked potential detection()
title Assessment of hearing threshold in adults with hearing loss using an automated system of cortical auditory evoked potential detection()
title_full Assessment of hearing threshold in adults with hearing loss using an automated system of cortical auditory evoked potential detection()
title_fullStr Assessment of hearing threshold in adults with hearing loss using an automated system of cortical auditory evoked potential detection()
title_full_unstemmed Assessment of hearing threshold in adults with hearing loss using an automated system of cortical auditory evoked potential detection()
title_short Assessment of hearing threshold in adults with hearing loss using an automated system of cortical auditory evoked potential detection()
title_sort assessment of hearing threshold in adults with hearing loss using an automated system of cortical auditory evoked potential detection()
topic Original Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9442746/
https://www.ncbi.nlm.nih.gov/pubmed/27229658
http://dx.doi.org/10.1016/j.bjorl.2016.02.016
work_keys_str_mv AT durantealessandraspada assessmentofhearingthresholdinadultswithhearinglossusinganautomatedsystemofcorticalauditoryevokedpotentialdetection
AT wieselbergmargaritabernal assessmentofhearingthresholdinadultswithhearinglossusinganautomatedsystemofcorticalauditoryevokedpotentialdetection
AT roquenayara assessmentofhearingthresholdinadultswithhearinglossusinganautomatedsystemofcorticalauditoryevokedpotentialdetection
AT carvalhosheila assessmentofhearingthresholdinadultswithhearinglossusinganautomatedsystemofcorticalauditoryevokedpotentialdetection
AT puccibeatriz assessmentofhearingthresholdinadultswithhearinglossusinganautomatedsystemofcorticalauditoryevokedpotentialdetection
AT gudayolnicolly assessmentofhearingthresholdinadultswithhearinglossusinganautomatedsystemofcorticalauditoryevokedpotentialdetection
AT dealmeidakatia assessmentofhearingthresholdinadultswithhearinglossusinganautomatedsystemofcorticalauditoryevokedpotentialdetection