Cargando…

High-frequency audiometry in young and older adults when conventional audiometry is normal

High-frequency audiometry can detect early changes in auditory sensitivity resulting from processes such as aging. Nonetheless its use is still limited, and additional studies are required to establish its use, particularly among older adults. AIM: To compare pure tone thresholds for frequencies fro...

Descripción completa

Detalles Bibliográficos
Autores principales: de Castro Silva, Isabella Monteiro, Feitosa, Maria Ângela Guimarães
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Elsevier 2015
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9443560/
https://www.ncbi.nlm.nih.gov/pubmed/17221060
http://dx.doi.org/10.1016/S1808-8694(15)31024-7
_version_ 1784783011464609792
author de Castro Silva, Isabella Monteiro
Feitosa, Maria Ângela Guimarães
author_facet de Castro Silva, Isabella Monteiro
Feitosa, Maria Ângela Guimarães
author_sort de Castro Silva, Isabella Monteiro
collection PubMed
description High-frequency audiometry can detect early changes in auditory sensitivity resulting from processes such as aging. Nonetheless its use is still limited, and additional studies are required to establish its use, particularly among older adults. AIM: To compare pure tone thresholds for frequencies from 250 Hz to 16 kHz in young and older adults, with or without audiologic complaints. METHOD: Pure tone sensitivity to 250 Hz to 16 kHz was assessed with an AC-40 audiometer in 64 adults, evenly distributed in young (25 to 35 years-old) and older (45 to 55 years-old) adults of both sexes. This is a cross-sectional study. RESULTS: Although all participants presented normal audiometry in frequencies from 250 Hz to 8 kHz, according to clinical parameters, older adults had significantly higher thresholds compared to young adults, according to statistical parameters, with greater significance in higher frequencies (8 to 16 kHz). Presence or absence of clinical complaints did not distinguish thresholds. CONCLUSIONS: The process of auditory aging, including loss of sensitivity to higher frequencies, can be detected at earlier ages than those usually investigated. High frequency audiometry is an important instrument to distinguish auditory sensitivity in young and older adults, even for those considered as audiologically normal.
format Online
Article
Text
id pubmed-9443560
institution National Center for Biotechnology Information
language English
publishDate 2015
publisher Elsevier
record_format MEDLINE/PubMed
spelling pubmed-94435602022-09-09 High-frequency audiometry in young and older adults when conventional audiometry is normal de Castro Silva, Isabella Monteiro Feitosa, Maria Ângela Guimarães Braz J Otorhinolaryngol Original Article High-frequency audiometry can detect early changes in auditory sensitivity resulting from processes such as aging. Nonetheless its use is still limited, and additional studies are required to establish its use, particularly among older adults. AIM: To compare pure tone thresholds for frequencies from 250 Hz to 16 kHz in young and older adults, with or without audiologic complaints. METHOD: Pure tone sensitivity to 250 Hz to 16 kHz was assessed with an AC-40 audiometer in 64 adults, evenly distributed in young (25 to 35 years-old) and older (45 to 55 years-old) adults of both sexes. This is a cross-sectional study. RESULTS: Although all participants presented normal audiometry in frequencies from 250 Hz to 8 kHz, according to clinical parameters, older adults had significantly higher thresholds compared to young adults, according to statistical parameters, with greater significance in higher frequencies (8 to 16 kHz). Presence or absence of clinical complaints did not distinguish thresholds. CONCLUSIONS: The process of auditory aging, including loss of sensitivity to higher frequencies, can be detected at earlier ages than those usually investigated. High frequency audiometry is an important instrument to distinguish auditory sensitivity in young and older adults, even for those considered as audiologically normal. Elsevier 2015-10-19 /pmc/articles/PMC9443560/ /pubmed/17221060 http://dx.doi.org/10.1016/S1808-8694(15)31024-7 Text en . https://creativecommons.org/licenses/by/4.0/This is an open access article under the CC BY license (http://creativecommons.org/licenses/by/4.0/).
spellingShingle Original Article
de Castro Silva, Isabella Monteiro
Feitosa, Maria Ângela Guimarães
High-frequency audiometry in young and older adults when conventional audiometry is normal
title High-frequency audiometry in young and older adults when conventional audiometry is normal
title_full High-frequency audiometry in young and older adults when conventional audiometry is normal
title_fullStr High-frequency audiometry in young and older adults when conventional audiometry is normal
title_full_unstemmed High-frequency audiometry in young and older adults when conventional audiometry is normal
title_short High-frequency audiometry in young and older adults when conventional audiometry is normal
title_sort high-frequency audiometry in young and older adults when conventional audiometry is normal
topic Original Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9443560/
https://www.ncbi.nlm.nih.gov/pubmed/17221060
http://dx.doi.org/10.1016/S1808-8694(15)31024-7
work_keys_str_mv AT decastrosilvaisabellamonteiro highfrequencyaudiometryinyoungandolderadultswhenconventionalaudiometryisnormal
AT feitosamariaangelaguimaraes highfrequencyaudiometryinyoungandolderadultswhenconventionalaudiometryisnormal