Cargando…

Objective computorized evaluation of normal patterns of facial muscles contraction

Different methods used to evaluate the movements of the face have many degrees of subjectivity and reliability. The authors discuss the ease of using these methods in clinical practice or their accuracy in scientific research. AIM: To obtain the standard for normal facial muscles movements using an...

Descripción completa

Detalles Bibliográficos
Autores principales: Jorge, Jose Jarjura, Pialarissi, Paulo Roberto, Borges, Godofredo Campos, Squella, Sara Agueda Fuenzalida, de Fatiima de Gouveia, Maria, Saragiotto, Jose Carlos, Gonçalves, Victor Ribeiro
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Elsevier 2015
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9443831/
https://www.ncbi.nlm.nih.gov/pubmed/22499369
http://dx.doi.org/10.1590/S1808-86942012000200008
_version_ 1784783076387192832
author Jorge, Jose Jarjura
Pialarissi, Paulo Roberto
Borges, Godofredo Campos
Squella, Sara Agueda Fuenzalida
de Fatiima de Gouveia, Maria
Saragiotto, Jose Carlos
Gonçalves, Victor Ribeiro
author_facet Jorge, Jose Jarjura
Pialarissi, Paulo Roberto
Borges, Godofredo Campos
Squella, Sara Agueda Fuenzalida
de Fatiima de Gouveia, Maria
Saragiotto, Jose Carlos
Gonçalves, Victor Ribeiro
author_sort Jorge, Jose Jarjura
collection PubMed
description Different methods used to evaluate the movements of the face have many degrees of subjectivity and reliability. The authors discuss the ease of using these methods in clinical practice or their accuracy in scientific research. AIM: To obtain the standard for normal facial muscles movements using an objective method – the Vicon system. MATERIALS AND METHODS: Light reflective markers were placed at points of interest on the face of 12 normal subjects. The movements were captured by cameras that sent the images to a computer. The points' displacements were measured between rest and maximum muscle contraction; and we calculated the means and the standard deviations (SD) were calculated. RESULTS: When smiling, the variation of the oral commissures was between 6.45 and 12.11 mm, mean of 9.28 mm and SD od 2.83; for lifting the eyebrow, it is between 6.0 and 13.08 mm, mean of 10.57 mm and SD of 2.51; for eyelids movement there was a variation of 6.89 and 11.29 mm, with a mean value of 9.09 mm and SD of 2.20; for the movement of wrinkling the forehead, the results showed a variation of 4.16 and 10.85 mm, with a mean value of 7.56 and SD of 3.29. CONCLUSION: The authors obtained normal patterns for facial muscle contraction.
format Online
Article
Text
id pubmed-9443831
institution National Center for Biotechnology Information
language English
publishDate 2015
publisher Elsevier
record_format MEDLINE/PubMed
spelling pubmed-94438312022-09-09 Objective computorized evaluation of normal patterns of facial muscles contraction Jorge, Jose Jarjura Pialarissi, Paulo Roberto Borges, Godofredo Campos Squella, Sara Agueda Fuenzalida de Fatiima de Gouveia, Maria Saragiotto, Jose Carlos Gonçalves, Victor Ribeiro Braz J Otorhinolaryngol Original Article Different methods used to evaluate the movements of the face have many degrees of subjectivity and reliability. The authors discuss the ease of using these methods in clinical practice or their accuracy in scientific research. AIM: To obtain the standard for normal facial muscles movements using an objective method – the Vicon system. MATERIALS AND METHODS: Light reflective markers were placed at points of interest on the face of 12 normal subjects. The movements were captured by cameras that sent the images to a computer. The points' displacements were measured between rest and maximum muscle contraction; and we calculated the means and the standard deviations (SD) were calculated. RESULTS: When smiling, the variation of the oral commissures was between 6.45 and 12.11 mm, mean of 9.28 mm and SD od 2.83; for lifting the eyebrow, it is between 6.0 and 13.08 mm, mean of 10.57 mm and SD of 2.51; for eyelids movement there was a variation of 6.89 and 11.29 mm, with a mean value of 9.09 mm and SD of 2.20; for the movement of wrinkling the forehead, the results showed a variation of 4.16 and 10.85 mm, with a mean value of 7.56 and SD of 3.29. CONCLUSION: The authors obtained normal patterns for facial muscle contraction. Elsevier 2015-10-20 /pmc/articles/PMC9443831/ /pubmed/22499369 http://dx.doi.org/10.1590/S1808-86942012000200008 Text en . https://creativecommons.org/licenses/by/4.0/This is an open access article under the CC BY license (http://creativecommons.org/licenses/by/4.0/).
spellingShingle Original Article
Jorge, Jose Jarjura
Pialarissi, Paulo Roberto
Borges, Godofredo Campos
Squella, Sara Agueda Fuenzalida
de Fatiima de Gouveia, Maria
Saragiotto, Jose Carlos
Gonçalves, Victor Ribeiro
Objective computorized evaluation of normal patterns of facial muscles contraction
title Objective computorized evaluation of normal patterns of facial muscles contraction
title_full Objective computorized evaluation of normal patterns of facial muscles contraction
title_fullStr Objective computorized evaluation of normal patterns of facial muscles contraction
title_full_unstemmed Objective computorized evaluation of normal patterns of facial muscles contraction
title_short Objective computorized evaluation of normal patterns of facial muscles contraction
title_sort objective computorized evaluation of normal patterns of facial muscles contraction
topic Original Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9443831/
https://www.ncbi.nlm.nih.gov/pubmed/22499369
http://dx.doi.org/10.1590/S1808-86942012000200008
work_keys_str_mv AT jorgejosejarjura objectivecomputorizedevaluationofnormalpatternsoffacialmusclescontraction
AT pialarissipauloroberto objectivecomputorizedevaluationofnormalpatternsoffacialmusclescontraction
AT borgesgodofredocampos objectivecomputorizedevaluationofnormalpatternsoffacialmusclescontraction
AT squellasaraaguedafuenzalida objectivecomputorizedevaluationofnormalpatternsoffacialmusclescontraction
AT defatiimadegouveiamaria objectivecomputorizedevaluationofnormalpatternsoffacialmusclescontraction
AT saragiottojosecarlos objectivecomputorizedevaluationofnormalpatternsoffacialmusclescontraction
AT goncalvesvictorribeiro objectivecomputorizedevaluationofnormalpatternsoffacialmusclescontraction