Cargando…
Audiometric evaluation after stapedotomy with Fisch titanium prosthesis
Otosclerosis causes the fixation of the stapes and conductive hearing loss, usually corrected with the use of hearing aids or through stapedotomy and the replacement of the involved stapes with a prosthesis. Titanium has been the most recently used material of choice in stapedotomy prostheses. Only...
Autores principales: | , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Elsevier
2015
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9443872/ https://www.ncbi.nlm.nih.gov/pubmed/23743748 http://dx.doi.org/10.5935/1808-8694.20130058 |
_version_ | 1784783086431502336 |
---|---|
author | de Ataide, Andre Luiz Bichinho, Gerson Linck Patruni, Tatiana Mauad |
author_facet | de Ataide, Andre Luiz Bichinho, Gerson Linck Patruni, Tatiana Mauad |
author_sort | de Ataide, Andre Luiz |
collection | PubMed |
description | Otosclerosis causes the fixation of the stapes and conductive hearing loss, usually corrected with the use of hearing aids or through stapedotomy and the replacement of the involved stapes with a prosthesis. Titanium has been the most recently used material of choice in stapedotomy prostheses. Only two prostheses are commercially available in Brazil. There are no reports in the literature on the Fisch-type Storz titanium stapes piston prosthesis. OBJECTIVE: This retrospective study aims to look into the auditory outcomes of patients submitted to stapedotomy and titanium stapes piston prosthesis implantation. METHOD: The criteria described by the American Academy of Otolaryngology were used to compare pre and postoperative air-bone gaps seen in audiometry tests. RESULTS: The mean low-frequency postoperative air-bone gap was 12.9 dB; the mean high-frequency air-bone gap was 5.2 dB (mean 9.1 dB); median gap was 8.8 dB, with a minimum of 1.3 dB and a maximum of 21.6 dB; standard deviation was 5.7 dB, and p < 0.001. Twenty-five (75.8%) patients had air-bone gaps of 10 dB and under; 32 (96.9%) patients had gaps of 20 dB and under; and all patients had gaps of 30 dB and under. CONCLUSION: The Fisch-type titanium stapes piston prosthesis presented outcomes consistent with the literature and can be used safely in stapedotomy procedures. |
format | Online Article Text |
id | pubmed-9443872 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2015 |
publisher | Elsevier |
record_format | MEDLINE/PubMed |
spelling | pubmed-94438722022-09-09 Audiometric evaluation after stapedotomy with Fisch titanium prosthesis de Ataide, Andre Luiz Bichinho, Gerson Linck Patruni, Tatiana Mauad Braz J Otorhinolaryngol Original Article Otosclerosis causes the fixation of the stapes and conductive hearing loss, usually corrected with the use of hearing aids or through stapedotomy and the replacement of the involved stapes with a prosthesis. Titanium has been the most recently used material of choice in stapedotomy prostheses. Only two prostheses are commercially available in Brazil. There are no reports in the literature on the Fisch-type Storz titanium stapes piston prosthesis. OBJECTIVE: This retrospective study aims to look into the auditory outcomes of patients submitted to stapedotomy and titanium stapes piston prosthesis implantation. METHOD: The criteria described by the American Academy of Otolaryngology were used to compare pre and postoperative air-bone gaps seen in audiometry tests. RESULTS: The mean low-frequency postoperative air-bone gap was 12.9 dB; the mean high-frequency air-bone gap was 5.2 dB (mean 9.1 dB); median gap was 8.8 dB, with a minimum of 1.3 dB and a maximum of 21.6 dB; standard deviation was 5.7 dB, and p < 0.001. Twenty-five (75.8%) patients had air-bone gaps of 10 dB and under; 32 (96.9%) patients had gaps of 20 dB and under; and all patients had gaps of 30 dB and under. CONCLUSION: The Fisch-type titanium stapes piston prosthesis presented outcomes consistent with the literature and can be used safely in stapedotomy procedures. Elsevier 2015-10-04 /pmc/articles/PMC9443872/ /pubmed/23743748 http://dx.doi.org/10.5935/1808-8694.20130058 Text en . https://creativecommons.org/licenses/by/4.0/This is an open access article under the CC BY license (http://creativecommons.org/licenses/by/4.0/). |
spellingShingle | Original Article de Ataide, Andre Luiz Bichinho, Gerson Linck Patruni, Tatiana Mauad Audiometric evaluation after stapedotomy with Fisch titanium prosthesis |
title | Audiometric evaluation after stapedotomy with Fisch titanium prosthesis |
title_full | Audiometric evaluation after stapedotomy with Fisch titanium prosthesis |
title_fullStr | Audiometric evaluation after stapedotomy with Fisch titanium prosthesis |
title_full_unstemmed | Audiometric evaluation after stapedotomy with Fisch titanium prosthesis |
title_short | Audiometric evaluation after stapedotomy with Fisch titanium prosthesis |
title_sort | audiometric evaluation after stapedotomy with fisch titanium prosthesis |
topic | Original Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9443872/ https://www.ncbi.nlm.nih.gov/pubmed/23743748 http://dx.doi.org/10.5935/1808-8694.20130058 |
work_keys_str_mv | AT deataideandreluiz audiometricevaluationafterstapedotomywithfischtitaniumprosthesis AT bichinhogersonlinck audiometricevaluationafterstapedotomywithfischtitaniumprosthesis AT patrunitatianamauad audiometricevaluationafterstapedotomywithfischtitaniumprosthesis |