Reliability, minimal detectable change and measurement errors in knee extension muscle strength measurement using a hand-held dynamometer in young children

[Purpose] Few studies have assessed the reliability of muscle strength measurement using a hand-held dynamometer, specifically in Japanese young children. This study aims to investigate the reliability, minimal detectable change and measurement error in knee extension muscle strength measurements in...

Descripción completa

Detalles Bibliográficos
Autores principales: Shigeshima, Koji, Yamasaki, Hiroshi, Katayama, Kunihiro
Formato: Online Artículo Texto
Lenguaje:English
Publicado: The Society of Physical Therapy Science 2022
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9444515/
https://www.ncbi.nlm.nih.gov/pubmed/36118657
http://dx.doi.org/10.1589/jpts.34.614
_version_ 1784783242567614464
author Shigeshima, Koji
Yamasaki, Hiroshi
Katayama, Kunihiro
author_facet Shigeshima, Koji
Yamasaki, Hiroshi
Katayama, Kunihiro
author_sort Shigeshima, Koji
collection PubMed
description [Purpose] Few studies have assessed the reliability of muscle strength measurement using a hand-held dynamometer, specifically in Japanese young children. This study aims to investigate the reliability, minimal detectable change and measurement error in knee extension muscle strength measurements in young children using a hand-held dynamometer. [Participants and Methods] The study participants comprised 36 kindergarten-enrolled children of 3–6 years age. An experienced physiotherapist measured their isometric knee extension strength. Appropriate orientation and practices were performed prior to measurement. The same physiotherapist took the muscle measurements twice; and the maximum value was used as the muscle strength value. The measurements were repeated at intervals of approximately 30 min to verify reproducibility. [Results] The initial isometric knee extension strength was 10.6 ± 3.3 kgf and the Intra-class correlation coefficient (1,1) was 0.765. The standard error of measurement was 1.6 kgf and the minimal detectable change was 4.4 kgf. No significant systematic errors were observed. [Conclusion] Isometric knee extension strength measurement using a hand-held dynamometer in young children has good reliability with a low risk of systematic errors.
format Online
Article
Text
id pubmed-9444515
institution National Center for Biotechnology Information
language English
publishDate 2022
publisher The Society of Physical Therapy Science
record_format MEDLINE/PubMed
spelling pubmed-94445152022-09-16 Reliability, minimal detectable change and measurement errors in knee extension muscle strength measurement using a hand-held dynamometer in young children Shigeshima, Koji Yamasaki, Hiroshi Katayama, Kunihiro J Phys Ther Sci Original Article [Purpose] Few studies have assessed the reliability of muscle strength measurement using a hand-held dynamometer, specifically in Japanese young children. This study aims to investigate the reliability, minimal detectable change and measurement error in knee extension muscle strength measurements in young children using a hand-held dynamometer. [Participants and Methods] The study participants comprised 36 kindergarten-enrolled children of 3–6 years age. An experienced physiotherapist measured their isometric knee extension strength. Appropriate orientation and practices were performed prior to measurement. The same physiotherapist took the muscle measurements twice; and the maximum value was used as the muscle strength value. The measurements were repeated at intervals of approximately 30 min to verify reproducibility. [Results] The initial isometric knee extension strength was 10.6 ± 3.3 kgf and the Intra-class correlation coefficient (1,1) was 0.765. The standard error of measurement was 1.6 kgf and the minimal detectable change was 4.4 kgf. No significant systematic errors were observed. [Conclusion] Isometric knee extension strength measurement using a hand-held dynamometer in young children has good reliability with a low risk of systematic errors. The Society of Physical Therapy Science 2022-09-01 2022-09 /pmc/articles/PMC9444515/ /pubmed/36118657 http://dx.doi.org/10.1589/jpts.34.614 Text en 2022©by the Society of Physical Therapy Science. Published by IPEC Inc. https://creativecommons.org/licenses/by-nc-nd/4.0/This is an open-access article distributed under the terms of the Creative Commons Attribution Non-Commercial No Derivatives (by-nc-nd) License. (CC-BY-NC-ND 4.0: https://creativecommons.org/licenses/by-nc-nd/4.0/)
spellingShingle Original Article
Shigeshima, Koji
Yamasaki, Hiroshi
Katayama, Kunihiro
Reliability, minimal detectable change and measurement errors in knee extension muscle strength measurement using a hand-held dynamometer in young children
title Reliability, minimal detectable change and measurement errors in knee extension muscle strength measurement using a hand-held dynamometer in young children
title_full Reliability, minimal detectable change and measurement errors in knee extension muscle strength measurement using a hand-held dynamometer in young children
title_fullStr Reliability, minimal detectable change and measurement errors in knee extension muscle strength measurement using a hand-held dynamometer in young children
title_full_unstemmed Reliability, minimal detectable change and measurement errors in knee extension muscle strength measurement using a hand-held dynamometer in young children
title_short Reliability, minimal detectable change and measurement errors in knee extension muscle strength measurement using a hand-held dynamometer in young children
title_sort reliability, minimal detectable change and measurement errors in knee extension muscle strength measurement using a hand-held dynamometer in young children
topic Original Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9444515/
https://www.ncbi.nlm.nih.gov/pubmed/36118657
http://dx.doi.org/10.1589/jpts.34.614
work_keys_str_mv AT shigeshimakoji reliabilityminimaldetectablechangeandmeasurementerrorsinkneeextensionmusclestrengthmeasurementusingahandhelddynamometerinyoungchildren
AT yamasakihiroshi reliabilityminimaldetectablechangeandmeasurementerrorsinkneeextensionmusclestrengthmeasurementusingahandhelddynamometerinyoungchildren
AT katayamakunihiro reliabilityminimaldetectablechangeandmeasurementerrorsinkneeextensionmusclestrengthmeasurementusingahandhelddynamometerinyoungchildren