Encoding of speech sounds at auditory brainstem level in good and poor hearing aid performers()
INTRODUCTION: Hearing aids are prescribed to alleviate loss of audibility. It has been reported that about 31% of hearing aid users reject their own hearing aid because of annoyance towards background noise. The reason for dissatisfaction can be located anywhere from the hearing aid microphone till...
Autores principales: | , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Elsevier
2016
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9444769/ https://www.ncbi.nlm.nih.gov/pubmed/27516129 http://dx.doi.org/10.1016/j.bjorl.2016.06.004 |
_version_ | 1784783305290285056 |
---|---|
author | Shetty, Hemanth Narayan Puttabasappa, Manjula |
author_facet | Shetty, Hemanth Narayan Puttabasappa, Manjula |
author_sort | Shetty, Hemanth Narayan |
collection | PubMed |
description | INTRODUCTION: Hearing aids are prescribed to alleviate loss of audibility. It has been reported that about 31% of hearing aid users reject their own hearing aid because of annoyance towards background noise. The reason for dissatisfaction can be located anywhere from the hearing aid microphone till the integrity of neurons along the auditory pathway. OBJECTIVES: To measure spectra from the output of hearing aid at the ear canal level and frequency following response recorded at the auditory brainstem from individuals with hearing impairment. METHODS: A total of sixty participants having moderate sensorineural hearing impairment with age range from 15 to 65 years were involved. Each participant was classified as either Good or Poor Hearing aid Performers based on acceptable noise level measure. Stimuli /da/ and /si/ were presented through loudspeaker at 65 dB SPL. At the ear canal, the spectra were measured in the unaided and aided conditions. At auditory brainstem, frequency following response were recorded to the same stimuli from the participants. RESULTS: Spectrum measured in each condition at ear canal was same in good hearing aid performers and poor hearing aid performers. At brainstem level, better F(0) encoding; F(0) and F(1) energies were significantly higher in good hearing aid performers than in poor hearing aid performers. Though the hearing aid spectra were almost same between good hearing aid performers and poor hearing aid performers, subtle physiological variations exist at the auditory brainstem. CONCLUSION: The result of the present study suggests that neural encoding of speech sound at the brainstem level might be mediated distinctly in good hearing aid performers from that of poor hearing aid performers. Thus, it can be inferred that subtle physiological changes are evident at the auditory brainstem in a person who is willing to accept noise from those who are not willing to accept noise. |
format | Online Article Text |
id | pubmed-9444769 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2016 |
publisher | Elsevier |
record_format | MEDLINE/PubMed |
spelling | pubmed-94447692022-09-09 Encoding of speech sounds at auditory brainstem level in good and poor hearing aid performers() Shetty, Hemanth Narayan Puttabasappa, Manjula Braz J Otorhinolaryngol Original Article INTRODUCTION: Hearing aids are prescribed to alleviate loss of audibility. It has been reported that about 31% of hearing aid users reject their own hearing aid because of annoyance towards background noise. The reason for dissatisfaction can be located anywhere from the hearing aid microphone till the integrity of neurons along the auditory pathway. OBJECTIVES: To measure spectra from the output of hearing aid at the ear canal level and frequency following response recorded at the auditory brainstem from individuals with hearing impairment. METHODS: A total of sixty participants having moderate sensorineural hearing impairment with age range from 15 to 65 years were involved. Each participant was classified as either Good or Poor Hearing aid Performers based on acceptable noise level measure. Stimuli /da/ and /si/ were presented through loudspeaker at 65 dB SPL. At the ear canal, the spectra were measured in the unaided and aided conditions. At auditory brainstem, frequency following response were recorded to the same stimuli from the participants. RESULTS: Spectrum measured in each condition at ear canal was same in good hearing aid performers and poor hearing aid performers. At brainstem level, better F(0) encoding; F(0) and F(1) energies were significantly higher in good hearing aid performers than in poor hearing aid performers. Though the hearing aid spectra were almost same between good hearing aid performers and poor hearing aid performers, subtle physiological variations exist at the auditory brainstem. CONCLUSION: The result of the present study suggests that neural encoding of speech sound at the brainstem level might be mediated distinctly in good hearing aid performers from that of poor hearing aid performers. Thus, it can be inferred that subtle physiological changes are evident at the auditory brainstem in a person who is willing to accept noise from those who are not willing to accept noise. Elsevier 2016-07-14 /pmc/articles/PMC9444769/ /pubmed/27516129 http://dx.doi.org/10.1016/j.bjorl.2016.06.004 Text en © 2016 Associação Brasileira de Otorrinolaringologia e Cirurgia Cérvico-Facial. Published by Elsevier Editora Ltda. https://creativecommons.org/licenses/by/4.0/This is an open access article under the CC BY license (http://creativecommons.org/licenses/by/4.0/). |
spellingShingle | Original Article Shetty, Hemanth Narayan Puttabasappa, Manjula Encoding of speech sounds at auditory brainstem level in good and poor hearing aid performers() |
title | Encoding of speech sounds at auditory brainstem level in good and poor hearing aid performers() |
title_full | Encoding of speech sounds at auditory brainstem level in good and poor hearing aid performers() |
title_fullStr | Encoding of speech sounds at auditory brainstem level in good and poor hearing aid performers() |
title_full_unstemmed | Encoding of speech sounds at auditory brainstem level in good and poor hearing aid performers() |
title_short | Encoding of speech sounds at auditory brainstem level in good and poor hearing aid performers() |
title_sort | encoding of speech sounds at auditory brainstem level in good and poor hearing aid performers() |
topic | Original Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9444769/ https://www.ncbi.nlm.nih.gov/pubmed/27516129 http://dx.doi.org/10.1016/j.bjorl.2016.06.004 |
work_keys_str_mv | AT shettyhemanthnarayan encodingofspeechsoundsatauditorybrainstemlevelingoodandpoorhearingaidperformers AT puttabasappamanjula encodingofspeechsoundsatauditorybrainstemlevelingoodandpoorhearingaidperformers |