Wearables for Measuring the Physical Activity and Sedentary Behavior of Patients With Axial Spondyloarthritis: Systematic Review

BACKGROUND: Axial spondyloarthritis (axSpA) is an inflammatory rheumatic disease associated with chronic back pain and restricted mobility and physical function. Increasing physical activity is a viable strategy for improving the health and quality of life of patients with axSpA. Thus, quantifying p...

Descripción completa

Detalles Bibliográficos
Autores principales: Soulard, Julie, Carlin, Thomas, Knitza, Johannes, Vuillerme, Nicolas
Formato: Online Artículo Texto
Lenguaje:English
Publicado: JMIR Publications 2022
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9446133/
https://www.ncbi.nlm.nih.gov/pubmed/35994315
http://dx.doi.org/10.2196/34734
_version_ 1784783580697722880
author Soulard, Julie
Carlin, Thomas
Knitza, Johannes
Vuillerme, Nicolas
author_facet Soulard, Julie
Carlin, Thomas
Knitza, Johannes
Vuillerme, Nicolas
author_sort Soulard, Julie
collection PubMed
description BACKGROUND: Axial spondyloarthritis (axSpA) is an inflammatory rheumatic disease associated with chronic back pain and restricted mobility and physical function. Increasing physical activity is a viable strategy for improving the health and quality of life of patients with axSpA. Thus, quantifying physical activity and sedentary behavior in this population is relevant to clinical outcomes and disease management. However, to the best of our knowledge, no systematic review to date has identified and synthesized the available evidence on the use of wearable devices to objectively measure the physical activity or sedentary behavior of patients with axSpA. OBJECTIVE: This study aimed to review the literature on the use of wearable activity trackers as outcome measures for physical activity and sedentary behavior in patients with axSpA. METHODS: PubMed, PEDro, and Cochrane electronic databases were searched in July 2021 for relevant original articles, with no limits on publication dates. Studies were included if they were original articles, targeted adults with a diagnosis of axSpA, and reported wearable device–measured physical activity or sedentary behavior among patients with axSpA. Data regarding the study’s characteristics, the sample description, the methods used for measuring physical activity and sedentary behavior (eg, wearable devices, assessment methods, and outcomes), and the main results of the physical activity and sedentary behavior assessments were extracted. RESULTS: A total of 31 studies were initially identified; 13 (13/31, 42%) met the inclusion criteria, including 819 patients with axSpA. All the studies used accelerometer-based wearable devices to assess physical activity. Of the 13 studies, 4 (4/31, 31%) studies also reported outcomes related to sedentary behavior. Wearable devices were secured on the wrists (3/13 studies, 23%), lower back (3/13, 23%), right hip (3/13, 23%), waist (2/13, 15%), anterior thigh (1/13, 8%), or right arm (1/13, 8%). The methods for reporting physical activity and sedentary behavior were heterogeneous. Approximately 77% (10/13) of studies had a monitoring period of 1 week, including weekend days. CONCLUSIONS: To date, few studies have used wearable devices to quantify the physical activity and sedentary behavior of patients with axSpA. The methodologies and results were heterogeneous, and none of these studies assessed the psychometric properties of these wearables in this specific population. Further investigation in this direction is needed before using wearable device–measured physical activity and sedentary behavior as outcome measures in intervention studies in patients with axSpA. TRIAL REGISTRATION: PROSPERO CRD42020182398; https://tinyurl.com/ec22jzkt INTERNATIONAL REGISTERED REPORT IDENTIFIER (IRRID): RR2-10.2196/23359
format Online
Article
Text
id pubmed-9446133
institution National Center for Biotechnology Information
language English
publishDate 2022
publisher JMIR Publications
record_format MEDLINE/PubMed
spelling pubmed-94461332022-09-07 Wearables for Measuring the Physical Activity and Sedentary Behavior of Patients With Axial Spondyloarthritis: Systematic Review Soulard, Julie Carlin, Thomas Knitza, Johannes Vuillerme, Nicolas JMIR Mhealth Uhealth Review BACKGROUND: Axial spondyloarthritis (axSpA) is an inflammatory rheumatic disease associated with chronic back pain and restricted mobility and physical function. Increasing physical activity is a viable strategy for improving the health and quality of life of patients with axSpA. Thus, quantifying physical activity and sedentary behavior in this population is relevant to clinical outcomes and disease management. However, to the best of our knowledge, no systematic review to date has identified and synthesized the available evidence on the use of wearable devices to objectively measure the physical activity or sedentary behavior of patients with axSpA. OBJECTIVE: This study aimed to review the literature on the use of wearable activity trackers as outcome measures for physical activity and sedentary behavior in patients with axSpA. METHODS: PubMed, PEDro, and Cochrane electronic databases were searched in July 2021 for relevant original articles, with no limits on publication dates. Studies were included if they were original articles, targeted adults with a diagnosis of axSpA, and reported wearable device–measured physical activity or sedentary behavior among patients with axSpA. Data regarding the study’s characteristics, the sample description, the methods used for measuring physical activity and sedentary behavior (eg, wearable devices, assessment methods, and outcomes), and the main results of the physical activity and sedentary behavior assessments were extracted. RESULTS: A total of 31 studies were initially identified; 13 (13/31, 42%) met the inclusion criteria, including 819 patients with axSpA. All the studies used accelerometer-based wearable devices to assess physical activity. Of the 13 studies, 4 (4/31, 31%) studies also reported outcomes related to sedentary behavior. Wearable devices were secured on the wrists (3/13 studies, 23%), lower back (3/13, 23%), right hip (3/13, 23%), waist (2/13, 15%), anterior thigh (1/13, 8%), or right arm (1/13, 8%). The methods for reporting physical activity and sedentary behavior were heterogeneous. Approximately 77% (10/13) of studies had a monitoring period of 1 week, including weekend days. CONCLUSIONS: To date, few studies have used wearable devices to quantify the physical activity and sedentary behavior of patients with axSpA. The methodologies and results were heterogeneous, and none of these studies assessed the psychometric properties of these wearables in this specific population. Further investigation in this direction is needed before using wearable device–measured physical activity and sedentary behavior as outcome measures in intervention studies in patients with axSpA. TRIAL REGISTRATION: PROSPERO CRD42020182398; https://tinyurl.com/ec22jzkt INTERNATIONAL REGISTERED REPORT IDENTIFIER (IRRID): RR2-10.2196/23359 JMIR Publications 2022-08-22 /pmc/articles/PMC9446133/ /pubmed/35994315 http://dx.doi.org/10.2196/34734 Text en ©Julie Soulard, Thomas Carlin, Johannes Knitza, Nicolas Vuillerme. Originally published in JMIR mHealth and uHealth (https://mhealth.jmir.org), 22.08.2022. https://creativecommons.org/licenses/by/4.0/This is an open-access article distributed under the terms of the Creative Commons Attribution License (https://creativecommons.org/licenses/by/4.0/), which permits unrestricted use, distribution, and reproduction in any medium, provided the original work, first published in JMIR mHealth and uHealth, is properly cited. The complete bibliographic information, a link to the original publication on https://mhealth.jmir.org/, as well as this copyright and license information must be included.
spellingShingle Review
Soulard, Julie
Carlin, Thomas
Knitza, Johannes
Vuillerme, Nicolas
Wearables for Measuring the Physical Activity and Sedentary Behavior of Patients With Axial Spondyloarthritis: Systematic Review
title Wearables for Measuring the Physical Activity and Sedentary Behavior of Patients With Axial Spondyloarthritis: Systematic Review
title_full Wearables for Measuring the Physical Activity and Sedentary Behavior of Patients With Axial Spondyloarthritis: Systematic Review
title_fullStr Wearables for Measuring the Physical Activity and Sedentary Behavior of Patients With Axial Spondyloarthritis: Systematic Review
title_full_unstemmed Wearables for Measuring the Physical Activity and Sedentary Behavior of Patients With Axial Spondyloarthritis: Systematic Review
title_short Wearables for Measuring the Physical Activity and Sedentary Behavior of Patients With Axial Spondyloarthritis: Systematic Review
title_sort wearables for measuring the physical activity and sedentary behavior of patients with axial spondyloarthritis: systematic review
topic Review
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9446133/
https://www.ncbi.nlm.nih.gov/pubmed/35994315
http://dx.doi.org/10.2196/34734
work_keys_str_mv AT soulardjulie wearablesformeasuringthephysicalactivityandsedentarybehaviorofpatientswithaxialspondyloarthritissystematicreview
AT carlinthomas wearablesformeasuringthephysicalactivityandsedentarybehaviorofpatientswithaxialspondyloarthritissystematicreview
AT knitzajohannes wearablesformeasuringthephysicalactivityandsedentarybehaviorofpatientswithaxialspondyloarthritissystematicreview
AT vuillermenicolas wearablesformeasuringthephysicalactivityandsedentarybehaviorofpatientswithaxialspondyloarthritissystematicreview