Improving Performance and Access to Difficult-to-Reach Anatomy with a Powered Articulating Stapler

BACKGROUND: Modern surgical staplers should provide precise placement and transection, especially in tight spaces and on thick tissue. Ideally, a stapler would move to accommodate variations in the tissue and anatomy instead of having to move the tissue around to fit the stapler. This study was unde...

Descripción completa

Detalles Bibliográficos
Autores principales: Huang, Zhifan F, Vandewalle, James A, Clymer, Jeffrey W, Ricketts, Crystal D, Petraiuolo, William J
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Dove 2022
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9447447/
https://www.ncbi.nlm.nih.gov/pubmed/36082377
http://dx.doi.org/10.2147/MDER.S379717
_version_ 1784783856303341568
author Huang, Zhifan F
Vandewalle, James A
Clymer, Jeffrey W
Ricketts, Crystal D
Petraiuolo, William J
author_facet Huang, Zhifan F
Vandewalle, James A
Clymer, Jeffrey W
Ricketts, Crystal D
Petraiuolo, William J
author_sort Huang, Zhifan F
collection PubMed
description BACKGROUND: Modern surgical staplers should provide precise placement and transection, especially in tight spaces and on thick tissue. Ideally, a stapler would move to accommodate variations in the tissue and anatomy instead of having to move the tissue around to fit the stapler. This study was undertaken to evaluate the performance characteristics of the new Echelon 3000 Stapler (ECH3). Use of the ECH3 was compared to another marketed stapler, including tests for access, seal strength, staple formation in thick tissue, and end effector stability. METHODS: Pelvic anatomy measurements were used to construct a virtual model of a Low Anterior Resection (LAR). Monte Carlo simulations were performed on the staplers to compare the probability of completing a transection with one or two firings. Using water infusion of stapled porcine ileum, pressure at first leak and percentage of leaks at critical pressures were measured. Rate of malformed staples was measured in thick tissue. End effector stability while firing and under moderate pressure were compared between staplers. After use, surgeons were surveyed on the functionality of the device. RESULTS: ECH3 had a markedly higher probability of completing an LAR transection in one or two firings than the comparator stapler. Median initial leak pressure of stapled ileum was significantly higher, and rate of leaks was lower at 40 and 50 mmHg. ECH3 had fewer malformed staples for both 3.3- and 4.0-mm thick tissue. The end effector exhibited less angular movement during firing, and less deflection under a moderate load. Surgeons agreed the ECH3 provided precise placement and easy one-handed operation. CONCLUSION: The Echelon 3000 Stapler demonstrated improved access capability, tighter seals, fewer malformed staples, and greater end effector stability. These advantages were recognized by surgeons who evaluated the use of the device preclinically.
format Online
Article
Text
id pubmed-9447447
institution National Center for Biotechnology Information
language English
publishDate 2022
publisher Dove
record_format MEDLINE/PubMed
spelling pubmed-94474472022-09-07 Improving Performance and Access to Difficult-to-Reach Anatomy with a Powered Articulating Stapler Huang, Zhifan F Vandewalle, James A Clymer, Jeffrey W Ricketts, Crystal D Petraiuolo, William J Med Devices (Auckl) Original Research BACKGROUND: Modern surgical staplers should provide precise placement and transection, especially in tight spaces and on thick tissue. Ideally, a stapler would move to accommodate variations in the tissue and anatomy instead of having to move the tissue around to fit the stapler. This study was undertaken to evaluate the performance characteristics of the new Echelon 3000 Stapler (ECH3). Use of the ECH3 was compared to another marketed stapler, including tests for access, seal strength, staple formation in thick tissue, and end effector stability. METHODS: Pelvic anatomy measurements were used to construct a virtual model of a Low Anterior Resection (LAR). Monte Carlo simulations were performed on the staplers to compare the probability of completing a transection with one or two firings. Using water infusion of stapled porcine ileum, pressure at first leak and percentage of leaks at critical pressures were measured. Rate of malformed staples was measured in thick tissue. End effector stability while firing and under moderate pressure were compared between staplers. After use, surgeons were surveyed on the functionality of the device. RESULTS: ECH3 had a markedly higher probability of completing an LAR transection in one or two firings than the comparator stapler. Median initial leak pressure of stapled ileum was significantly higher, and rate of leaks was lower at 40 and 50 mmHg. ECH3 had fewer malformed staples for both 3.3- and 4.0-mm thick tissue. The end effector exhibited less angular movement during firing, and less deflection under a moderate load. Surgeons agreed the ECH3 provided precise placement and easy one-handed operation. CONCLUSION: The Echelon 3000 Stapler demonstrated improved access capability, tighter seals, fewer malformed staples, and greater end effector stability. These advantages were recognized by surgeons who evaluated the use of the device preclinically. Dove 2022-09-02 /pmc/articles/PMC9447447/ /pubmed/36082377 http://dx.doi.org/10.2147/MDER.S379717 Text en © 2022 Huang et al. https://creativecommons.org/licenses/by-nc/3.0/This work is published and licensed by Dove Medical Press Limited. The full terms of this license are available at https://www.dovepress.com/terms.php and incorporate the Creative Commons Attribution – Non Commercial (unported, v3.0) License (http://creativecommons.org/licenses/by-nc/3.0/ (https://creativecommons.org/licenses/by-nc/3.0/) ). By accessing the work you hereby accept the Terms. Non-commercial uses of the work are permitted without any further permission from Dove Medical Press Limited, provided the work is properly attributed. For permission for commercial use of this work, please see paragraphs 4.2 and 5 of our Terms (https://www.dovepress.com/terms.php).
spellingShingle Original Research
Huang, Zhifan F
Vandewalle, James A
Clymer, Jeffrey W
Ricketts, Crystal D
Petraiuolo, William J
Improving Performance and Access to Difficult-to-Reach Anatomy with a Powered Articulating Stapler
title Improving Performance and Access to Difficult-to-Reach Anatomy with a Powered Articulating Stapler
title_full Improving Performance and Access to Difficult-to-Reach Anatomy with a Powered Articulating Stapler
title_fullStr Improving Performance and Access to Difficult-to-Reach Anatomy with a Powered Articulating Stapler
title_full_unstemmed Improving Performance and Access to Difficult-to-Reach Anatomy with a Powered Articulating Stapler
title_short Improving Performance and Access to Difficult-to-Reach Anatomy with a Powered Articulating Stapler
title_sort improving performance and access to difficult-to-reach anatomy with a powered articulating stapler
topic Original Research
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9447447/
https://www.ncbi.nlm.nih.gov/pubmed/36082377
http://dx.doi.org/10.2147/MDER.S379717
work_keys_str_mv AT huangzhifanf improvingperformanceandaccesstodifficulttoreachanatomywithapoweredarticulatingstapler
AT vandewallejamesa improvingperformanceandaccesstodifficulttoreachanatomywithapoweredarticulatingstapler
AT clymerjeffreyw improvingperformanceandaccesstodifficulttoreachanatomywithapoweredarticulatingstapler
AT rickettscrystald improvingperformanceandaccesstodifficulttoreachanatomywithapoweredarticulatingstapler
AT petraiuolowilliamj improvingperformanceandaccesstodifficulttoreachanatomywithapoweredarticulatingstapler