Cargando…
Assessment of the light intensity of otoscopes utilized in teaching hospitals()()
INTRODUCTION: To attain an accurate otoscopic diagnosis, a functioning device with adequate capacity must be used. OBJECTIVE: Evaluate the light intensity of otoscopes, comparing it utilizing the batteries present at the moment of calibration and after new batteries were supplied. METHODS: Cross-sec...
Autores principales: | , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Elsevier
2015
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9449048/ https://www.ncbi.nlm.nih.gov/pubmed/26277834 http://dx.doi.org/10.1016/j.bjorl.2015.07.006 |
_version_ | 1784784203759484928 |
---|---|
author | Fonseca, Vinicius Ribas Basso, Giovana Bittencourt Cavalheiro, Mariana Nagata |
author_facet | Fonseca, Vinicius Ribas Basso, Giovana Bittencourt Cavalheiro, Mariana Nagata |
author_sort | Fonseca, Vinicius Ribas |
collection | PubMed |
description | INTRODUCTION: To attain an accurate otoscopic diagnosis, a functioning device with adequate capacity must be used. OBJECTIVE: Evaluate the light intensity of otoscopes, comparing it utilizing the batteries present at the moment of calibration and after new batteries were supplied. METHODS: Cross-sectional study of a historical cohort, which assessed 38 otoscopes, measuring the light intensity with the batteries present at the moment of assessment compared to the intensity with new batteries, as well as charge of the test batteries and the new batteries. RESULTS: The mean of the sum of new batteries’ charge was 3.19 V, and of the test batteries was 2.70 V, representing a decrease of 18.02% in charge. The mean luminosity with the new batteries was 366.89 lumens, whereas in the test batteries it was 188.32 lumens, representing a decrease of 83.75% in the light intensity. Student's t-test was applied for data comparison, showing a statistical difference between the light intensity with the original batteries and the new batteries (p = 0.0001; CI = 0.95). CONCLUSION: There was a statistically significant difference between the proportions of light intensity in the otoscopes. A small variation in battery charge results in a great variation in light. |
format | Online Article Text |
id | pubmed-9449048 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2015 |
publisher | Elsevier |
record_format | MEDLINE/PubMed |
spelling | pubmed-94490482022-09-09 Assessment of the light intensity of otoscopes utilized in teaching hospitals()() Fonseca, Vinicius Ribas Basso, Giovana Bittencourt Cavalheiro, Mariana Nagata Braz J Otorhinolaryngol Original Article INTRODUCTION: To attain an accurate otoscopic diagnosis, a functioning device with adequate capacity must be used. OBJECTIVE: Evaluate the light intensity of otoscopes, comparing it utilizing the batteries present at the moment of calibration and after new batteries were supplied. METHODS: Cross-sectional study of a historical cohort, which assessed 38 otoscopes, measuring the light intensity with the batteries present at the moment of assessment compared to the intensity with new batteries, as well as charge of the test batteries and the new batteries. RESULTS: The mean of the sum of new batteries’ charge was 3.19 V, and of the test batteries was 2.70 V, representing a decrease of 18.02% in charge. The mean luminosity with the new batteries was 366.89 lumens, whereas in the test batteries it was 188.32 lumens, representing a decrease of 83.75% in the light intensity. Student's t-test was applied for data comparison, showing a statistical difference between the light intensity with the original batteries and the new batteries (p = 0.0001; CI = 0.95). CONCLUSION: There was a statistically significant difference between the proportions of light intensity in the otoscopes. A small variation in battery charge results in a great variation in light. Elsevier 2015-07-21 /pmc/articles/PMC9449048/ /pubmed/26277834 http://dx.doi.org/10.1016/j.bjorl.2015.07.006 Text en © 2015 Associac¸ão Brasileira de Otorrinolaringologia e Cirurgia Cérvico-Facial. Published by Elsevier Editora Ltda. All rights reserved. https://creativecommons.org/licenses/by-nc-nd/4.0/This is an open access article under the CC BY-NC-ND license (http://creativecommons.org/licenses/by-nc-nd/4.0/). |
spellingShingle | Original Article Fonseca, Vinicius Ribas Basso, Giovana Bittencourt Cavalheiro, Mariana Nagata Assessment of the light intensity of otoscopes utilized in teaching hospitals()() |
title | Assessment of the light intensity of otoscopes utilized in teaching hospitals()() |
title_full | Assessment of the light intensity of otoscopes utilized in teaching hospitals()() |
title_fullStr | Assessment of the light intensity of otoscopes utilized in teaching hospitals()() |
title_full_unstemmed | Assessment of the light intensity of otoscopes utilized in teaching hospitals()() |
title_short | Assessment of the light intensity of otoscopes utilized in teaching hospitals()() |
title_sort | assessment of the light intensity of otoscopes utilized in teaching hospitals()() |
topic | Original Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9449048/ https://www.ncbi.nlm.nih.gov/pubmed/26277834 http://dx.doi.org/10.1016/j.bjorl.2015.07.006 |
work_keys_str_mv | AT fonsecaviniciusribas assessmentofthelightintensityofotoscopesutilizedinteachinghospitals AT bassogiovanabittencourt assessmentofthelightintensityofotoscopesutilizedinteachinghospitals AT cavalheiromariananagata assessmentofthelightintensityofotoscopesutilizedinteachinghospitals |