Cargando…
Effect of transcatheter edge-to-edge repair device position on diastolic hemodynamic parameters: An echocardiography-based simulation study
BACKGROUND: Transcatheter edge-to-edge repair (TEER) has developed from innovative technology to an established treatment strategy of mitral regurgitation (MR). The risk of iatrogenic mitral stenosis after TEER is, however, a critical factor in the conflict of interest between maximal reduction of M...
Autores principales: | , , , , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Frontiers Media S.A.
2022
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9449143/ https://www.ncbi.nlm.nih.gov/pubmed/36093164 http://dx.doi.org/10.3389/fcvm.2022.915074 |
_version_ | 1784784226577547264 |
---|---|
author | Vellguth, Katharina Barbieri, Fabian Reinthaler, Markus Kasner, Mario Landmesser, Ulf Kuehne, Titus Hennemuth, Anja Walczak, Lars Goubergrits, Leonid |
author_facet | Vellguth, Katharina Barbieri, Fabian Reinthaler, Markus Kasner, Mario Landmesser, Ulf Kuehne, Titus Hennemuth, Anja Walczak, Lars Goubergrits, Leonid |
author_sort | Vellguth, Katharina |
collection | PubMed |
description | BACKGROUND: Transcatheter edge-to-edge repair (TEER) has developed from innovative technology to an established treatment strategy of mitral regurgitation (MR). The risk of iatrogenic mitral stenosis after TEER is, however, a critical factor in the conflict of interest between maximal reduction of MR and minimal impairment of left ventricular filling. We aim to investigate systematically the impact of device position on the post treatment hemodynamic outcome by involving the patient-specific segmentation of the diseased mitral valve. MATERIALS AND METHODS: Transesophageal echocardiographic image data of ten patients with severe MR (age: 57 ± 8 years, 20% female) were segmented and virtually treated with TEER at three positions by using a position based dynamics approach. Pre- and post-interventional patient geometries were preprocessed for computational fluid dynamics (CFD) and simulated at peak-diastole with patient-specific blood flow boundary conditions. Simulations were performed with boundary conditions mimicking rest and stress. The simulation results were compared with clinical data acquired for a cohort of 21 symptomatic MR patients (age: 79 ± 6 years, 43% female) treated with TEER. RESULTS: Virtual TEER reduces the mitral valve area (MVA) from 7.5 ± 1.6 to 2.6 ± 0.6 cm(2). Central device positioning resulted in a 14% smaller MVA than eccentric device positions. Furthermore, residual MVA is better predictable for central than for eccentric device positions (R(2) = 0.81 vs. R(2) = 0.49). The MVA reduction led to significantly higher maximal diastolic velocities (pre: 0.9 ± 0.2 m/s, post: 2.0 ± 0.5 m/s) and pressure gradients (pre: 1.5 ± 0.6 mmHg, post: 16.3 ± 9 mmHg) in spite of a mean flow rate reduction by 23% due to reduced MR after the treatment. On average, velocities were 12% and pressure gradients were 25% higher with devices in central compared to lateral or medial positions. CONCLUSION: Virtual TEER treatment combined with CFD is a promising tool for predicting individual morphometric and hemodynamic outcomes. Such a tool can potentially be used to support clinical decision making, procedure planning, and risk estimation to prevent post-procedural iatrogenic mitral stenosis. |
format | Online Article Text |
id | pubmed-9449143 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2022 |
publisher | Frontiers Media S.A. |
record_format | MEDLINE/PubMed |
spelling | pubmed-94491432022-09-08 Effect of transcatheter edge-to-edge repair device position on diastolic hemodynamic parameters: An echocardiography-based simulation study Vellguth, Katharina Barbieri, Fabian Reinthaler, Markus Kasner, Mario Landmesser, Ulf Kuehne, Titus Hennemuth, Anja Walczak, Lars Goubergrits, Leonid Front Cardiovasc Med Cardiovascular Medicine BACKGROUND: Transcatheter edge-to-edge repair (TEER) has developed from innovative technology to an established treatment strategy of mitral regurgitation (MR). The risk of iatrogenic mitral stenosis after TEER is, however, a critical factor in the conflict of interest between maximal reduction of MR and minimal impairment of left ventricular filling. We aim to investigate systematically the impact of device position on the post treatment hemodynamic outcome by involving the patient-specific segmentation of the diseased mitral valve. MATERIALS AND METHODS: Transesophageal echocardiographic image data of ten patients with severe MR (age: 57 ± 8 years, 20% female) were segmented and virtually treated with TEER at three positions by using a position based dynamics approach. Pre- and post-interventional patient geometries were preprocessed for computational fluid dynamics (CFD) and simulated at peak-diastole with patient-specific blood flow boundary conditions. Simulations were performed with boundary conditions mimicking rest and stress. The simulation results were compared with clinical data acquired for a cohort of 21 symptomatic MR patients (age: 79 ± 6 years, 43% female) treated with TEER. RESULTS: Virtual TEER reduces the mitral valve area (MVA) from 7.5 ± 1.6 to 2.6 ± 0.6 cm(2). Central device positioning resulted in a 14% smaller MVA than eccentric device positions. Furthermore, residual MVA is better predictable for central than for eccentric device positions (R(2) = 0.81 vs. R(2) = 0.49). The MVA reduction led to significantly higher maximal diastolic velocities (pre: 0.9 ± 0.2 m/s, post: 2.0 ± 0.5 m/s) and pressure gradients (pre: 1.5 ± 0.6 mmHg, post: 16.3 ± 9 mmHg) in spite of a mean flow rate reduction by 23% due to reduced MR after the treatment. On average, velocities were 12% and pressure gradients were 25% higher with devices in central compared to lateral or medial positions. CONCLUSION: Virtual TEER treatment combined with CFD is a promising tool for predicting individual morphometric and hemodynamic outcomes. Such a tool can potentially be used to support clinical decision making, procedure planning, and risk estimation to prevent post-procedural iatrogenic mitral stenosis. Frontiers Media S.A. 2022-08-24 /pmc/articles/PMC9449143/ /pubmed/36093164 http://dx.doi.org/10.3389/fcvm.2022.915074 Text en Copyright © 2022 Vellguth, Barbieri, Reinthaler, Kasner, Landmesser, Kuehne, Hennemuth, Walczak and Goubergrits. https://creativecommons.org/licenses/by/4.0/This is an open-access article distributed under the terms of the Creative Commons Attribution License (CC BY). The use, distribution or reproduction in other forums is permitted, provided the original author(s) and the copyright owner(s) are credited and that the original publication in this journal is cited, in accordance with accepted academic practice. No use, distribution or reproduction is permitted which does not comply with these terms. |
spellingShingle | Cardiovascular Medicine Vellguth, Katharina Barbieri, Fabian Reinthaler, Markus Kasner, Mario Landmesser, Ulf Kuehne, Titus Hennemuth, Anja Walczak, Lars Goubergrits, Leonid Effect of transcatheter edge-to-edge repair device position on diastolic hemodynamic parameters: An echocardiography-based simulation study |
title | Effect of transcatheter edge-to-edge repair device position on diastolic hemodynamic parameters: An echocardiography-based simulation study |
title_full | Effect of transcatheter edge-to-edge repair device position on diastolic hemodynamic parameters: An echocardiography-based simulation study |
title_fullStr | Effect of transcatheter edge-to-edge repair device position on diastolic hemodynamic parameters: An echocardiography-based simulation study |
title_full_unstemmed | Effect of transcatheter edge-to-edge repair device position on diastolic hemodynamic parameters: An echocardiography-based simulation study |
title_short | Effect of transcatheter edge-to-edge repair device position on diastolic hemodynamic parameters: An echocardiography-based simulation study |
title_sort | effect of transcatheter edge-to-edge repair device position on diastolic hemodynamic parameters: an echocardiography-based simulation study |
topic | Cardiovascular Medicine |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9449143/ https://www.ncbi.nlm.nih.gov/pubmed/36093164 http://dx.doi.org/10.3389/fcvm.2022.915074 |
work_keys_str_mv | AT vellguthkatharina effectoftranscatheteredgetoedgerepairdevicepositionondiastolichemodynamicparametersanechocardiographybasedsimulationstudy AT barbierifabian effectoftranscatheteredgetoedgerepairdevicepositionondiastolichemodynamicparametersanechocardiographybasedsimulationstudy AT reinthalermarkus effectoftranscatheteredgetoedgerepairdevicepositionondiastolichemodynamicparametersanechocardiographybasedsimulationstudy AT kasnermario effectoftranscatheteredgetoedgerepairdevicepositionondiastolichemodynamicparametersanechocardiographybasedsimulationstudy AT landmesserulf effectoftranscatheteredgetoedgerepairdevicepositionondiastolichemodynamicparametersanechocardiographybasedsimulationstudy AT kuehnetitus effectoftranscatheteredgetoedgerepairdevicepositionondiastolichemodynamicparametersanechocardiographybasedsimulationstudy AT hennemuthanja effectoftranscatheteredgetoedgerepairdevicepositionondiastolichemodynamicparametersanechocardiographybasedsimulationstudy AT walczaklars effectoftranscatheteredgetoedgerepairdevicepositionondiastolichemodynamicparametersanechocardiographybasedsimulationstudy AT goubergritsleonid effectoftranscatheteredgetoedgerepairdevicepositionondiastolichemodynamicparametersanechocardiographybasedsimulationstudy |