Cargando…

Real-time monitoring of isothermal nucleic acid amplification on a smartphone by using a portable electrochemical device for home-testing of SARS-CoV-2

Home-testing of SARS-CoV-2 is an ideal approach for controlling the pandemic of COVID-19 and alleviating the shortage of medical resource caused by this acute infectious disease. Herein, a portable device that enables real-time monitoring of isothermal nucleic acid amplification tests (INAATs) throu...

Descripción completa

Detalles Bibliográficos
Autores principales: Li, Qi, Li, Yang, Gao, Qian, Jiang, Chao, Tian, Qingwu, Ma, Cuiping, Shi, Chao
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Elsevier B.V. 2022
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9449873/
https://www.ncbi.nlm.nih.gov/pubmed/36156220
http://dx.doi.org/10.1016/j.aca.2022.340343
_version_ 1784784397492289536
author Li, Qi
Li, Yang
Gao, Qian
Jiang, Chao
Tian, Qingwu
Ma, Cuiping
Shi, Chao
author_facet Li, Qi
Li, Yang
Gao, Qian
Jiang, Chao
Tian, Qingwu
Ma, Cuiping
Shi, Chao
author_sort Li, Qi
collection PubMed
description Home-testing of SARS-CoV-2 is an ideal approach for controlling the pandemic of COVID-19 and alleviating the shortage of medical resource caused by this acute infectious disease. Herein, a portable device that enables real-time monitoring of isothermal nucleic acid amplification tests (INAATs) through the electrochemistry method was fabricated for home-testing of SARS-CoV-2. First, a disposable plug-and-play pH-sensitive potentiometric sensor that matches this electrochemical INAATs (E-INAATs) device was designed to allow the label-free pH sensing detection of nucleic acid. By applying Nafion film on the polyaniline-based working electrode, this sensor exhibited an excellent linear potentiometric response to pH value in the range of 6.0–8.5 with a slope of −37.45 ± 1.96 mV/pH unit. A Bluetooth module was integrated into this device to enable the users real-time monitoring INAATs on their smartphones at home. Moreover, by presetting criteria, the detection results could be automatically judged by the device to avoid human errors. Finally, the utility of this E-INAATs device was demonstrated by detecting the presence of SARS-CoV-2 nucleocapsid protein gene in artificial samples with a sensitivity of 2 × 10(2) copies/test within 25 min, which was comparable with fluorescence and colorimetric assay. This portable, easy-operated, sensitive, and affordable device is particularly desirable for the full integration of household SARS-CoV-2 detection products and will open a new prospect for the control of infectious diseases via electrochemical NAATs.
format Online
Article
Text
id pubmed-9449873
institution National Center for Biotechnology Information
language English
publishDate 2022
publisher Elsevier B.V.
record_format MEDLINE/PubMed
spelling pubmed-94498732022-09-07 Real-time monitoring of isothermal nucleic acid amplification on a smartphone by using a portable electrochemical device for home-testing of SARS-CoV-2 Li, Qi Li, Yang Gao, Qian Jiang, Chao Tian, Qingwu Ma, Cuiping Shi, Chao Anal Chim Acta Article Home-testing of SARS-CoV-2 is an ideal approach for controlling the pandemic of COVID-19 and alleviating the shortage of medical resource caused by this acute infectious disease. Herein, a portable device that enables real-time monitoring of isothermal nucleic acid amplification tests (INAATs) through the electrochemistry method was fabricated for home-testing of SARS-CoV-2. First, a disposable plug-and-play pH-sensitive potentiometric sensor that matches this electrochemical INAATs (E-INAATs) device was designed to allow the label-free pH sensing detection of nucleic acid. By applying Nafion film on the polyaniline-based working electrode, this sensor exhibited an excellent linear potentiometric response to pH value in the range of 6.0–8.5 with a slope of −37.45 ± 1.96 mV/pH unit. A Bluetooth module was integrated into this device to enable the users real-time monitoring INAATs on their smartphones at home. Moreover, by presetting criteria, the detection results could be automatically judged by the device to avoid human errors. Finally, the utility of this E-INAATs device was demonstrated by detecting the presence of SARS-CoV-2 nucleocapsid protein gene in artificial samples with a sensitivity of 2 × 10(2) copies/test within 25 min, which was comparable with fluorescence and colorimetric assay. This portable, easy-operated, sensitive, and affordable device is particularly desirable for the full integration of household SARS-CoV-2 detection products and will open a new prospect for the control of infectious diseases via electrochemical NAATs. Elsevier B.V. 2022-10-09 2022-09-07 /pmc/articles/PMC9449873/ /pubmed/36156220 http://dx.doi.org/10.1016/j.aca.2022.340343 Text en © 2022 Elsevier B.V. All rights reserved. Since January 2020 Elsevier has created a COVID-19 resource centre with free information in English and Mandarin on the novel coronavirus COVID-19. The COVID-19 resource centre is hosted on Elsevier Connect, the company's public news and information website. Elsevier hereby grants permission to make all its COVID-19-related research that is available on the COVID-19 resource centre - including this research content - immediately available in PubMed Central and other publicly funded repositories, such as the WHO COVID database with rights for unrestricted research re-use and analyses in any form or by any means with acknowledgement of the original source. These permissions are granted for free by Elsevier for as long as the COVID-19 resource centre remains active.
spellingShingle Article
Li, Qi
Li, Yang
Gao, Qian
Jiang, Chao
Tian, Qingwu
Ma, Cuiping
Shi, Chao
Real-time monitoring of isothermal nucleic acid amplification on a smartphone by using a portable electrochemical device for home-testing of SARS-CoV-2
title Real-time monitoring of isothermal nucleic acid amplification on a smartphone by using a portable electrochemical device for home-testing of SARS-CoV-2
title_full Real-time monitoring of isothermal nucleic acid amplification on a smartphone by using a portable electrochemical device for home-testing of SARS-CoV-2
title_fullStr Real-time monitoring of isothermal nucleic acid amplification on a smartphone by using a portable electrochemical device for home-testing of SARS-CoV-2
title_full_unstemmed Real-time monitoring of isothermal nucleic acid amplification on a smartphone by using a portable electrochemical device for home-testing of SARS-CoV-2
title_short Real-time monitoring of isothermal nucleic acid amplification on a smartphone by using a portable electrochemical device for home-testing of SARS-CoV-2
title_sort real-time monitoring of isothermal nucleic acid amplification on a smartphone by using a portable electrochemical device for home-testing of sars-cov-2
topic Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9449873/
https://www.ncbi.nlm.nih.gov/pubmed/36156220
http://dx.doi.org/10.1016/j.aca.2022.340343
work_keys_str_mv AT liqi realtimemonitoringofisothermalnucleicacidamplificationonasmartphonebyusingaportableelectrochemicaldeviceforhometestingofsarscov2
AT liyang realtimemonitoringofisothermalnucleicacidamplificationonasmartphonebyusingaportableelectrochemicaldeviceforhometestingofsarscov2
AT gaoqian realtimemonitoringofisothermalnucleicacidamplificationonasmartphonebyusingaportableelectrochemicaldeviceforhometestingofsarscov2
AT jiangchao realtimemonitoringofisothermalnucleicacidamplificationonasmartphonebyusingaportableelectrochemicaldeviceforhometestingofsarscov2
AT tianqingwu realtimemonitoringofisothermalnucleicacidamplificationonasmartphonebyusingaportableelectrochemicaldeviceforhometestingofsarscov2
AT macuiping realtimemonitoringofisothermalnucleicacidamplificationonasmartphonebyusingaportableelectrochemicaldeviceforhometestingofsarscov2
AT shichao realtimemonitoringofisothermalnucleicacidamplificationonasmartphonebyusingaportableelectrochemicaldeviceforhometestingofsarscov2