Cargando…

Extratympanic electrocochleography in the diagnosis of auditory neuropathy/auditory dyssynchrony

The brainstem auditory evoked potential (BAEP) is being extensively used as a method for the evaluation of cochlear function in individuals with diagnosis of auditory neuropathy/auditory dyssynchrony (AN/AD). In the absence of otoacoustic emissions, many cases of AN/AD have been diagnosed by the pre...

Descripción completa

Detalles Bibliográficos
Autores principales: Anastasio, Adriana Ribeiro Tavares, Alvarenga, Kátia de Freitas, Filho, Orozimbo Alves Costa
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Elsevier 2015
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9450606/
https://www.ncbi.nlm.nih.gov/pubmed/18392514
http://dx.doi.org/10.1016/S1808-8694(15)30763-1
_version_ 1784784558209630208
author Anastasio, Adriana Ribeiro Tavares
Alvarenga, Kátia de Freitas
Filho, Orozimbo Alves Costa
author_facet Anastasio, Adriana Ribeiro Tavares
Alvarenga, Kátia de Freitas
Filho, Orozimbo Alves Costa
author_sort Anastasio, Adriana Ribeiro Tavares
collection PubMed
description The brainstem auditory evoked potential (BAEP) is being extensively used as a method for the evaluation of cochlear function in individuals with diagnosis of auditory neuropathy/auditory dyssynchrony (AN/AD). In the absence of otoacoustic emissions, many cases of AN/AD have been diagnosed by the presence of CM identified in the BAEP. AIM: to demonstrate the clinical applicability of extratympanic electrocochleography (ET-Ecochg) in the differential diagnosis of AN/AD compared to the BAEP. METHOD: a 4-year-old child with a diagnosis of AN/AD seen at the Audiological Research Center was submitted to ET-Ecochg with a 2000 Hz tone burst in rarefaction and condensation polarities. RESULTS: the ET-Ecochg exam was illustrated. Using an appropriate protocol, it was possible to demonstrate CM and to confirm it in the Ecochg, with a recording quality superior to that obtained in the BAEP. CONCLUSION: ET-Ecochg permitted a more detailed analysis of CM compared to the BAEP, thus showing clinical applicability for the investigation of cochlear function in AN/AD.
format Online
Article
Text
id pubmed-9450606
institution National Center for Biotechnology Information
language English
publishDate 2015
publisher Elsevier
record_format MEDLINE/PubMed
spelling pubmed-94506062022-09-09 Extratympanic electrocochleography in the diagnosis of auditory neuropathy/auditory dyssynchrony Anastasio, Adriana Ribeiro Tavares Alvarenga, Kátia de Freitas Filho, Orozimbo Alves Costa Braz J Otorhinolaryngol Review Article The brainstem auditory evoked potential (BAEP) is being extensively used as a method for the evaluation of cochlear function in individuals with diagnosis of auditory neuropathy/auditory dyssynchrony (AN/AD). In the absence of otoacoustic emissions, many cases of AN/AD have been diagnosed by the presence of CM identified in the BAEP. AIM: to demonstrate the clinical applicability of extratympanic electrocochleography (ET-Ecochg) in the differential diagnosis of AN/AD compared to the BAEP. METHOD: a 4-year-old child with a diagnosis of AN/AD seen at the Audiological Research Center was submitted to ET-Ecochg with a 2000 Hz tone burst in rarefaction and condensation polarities. RESULTS: the ET-Ecochg exam was illustrated. Using an appropriate protocol, it was possible to demonstrate CM and to confirm it in the Ecochg, with a recording quality superior to that obtained in the BAEP. CONCLUSION: ET-Ecochg permitted a more detailed analysis of CM compared to the BAEP, thus showing clinical applicability for the investigation of cochlear function in AN/AD. Elsevier 2015-10-19 /pmc/articles/PMC9450606/ /pubmed/18392514 http://dx.doi.org/10.1016/S1808-8694(15)30763-1 Text en . https://creativecommons.org/licenses/by/4.0/This is an open access article under the CC BY license (http://creativecommons.org/licenses/by/4.0/).
spellingShingle Review Article
Anastasio, Adriana Ribeiro Tavares
Alvarenga, Kátia de Freitas
Filho, Orozimbo Alves Costa
Extratympanic electrocochleography in the diagnosis of auditory neuropathy/auditory dyssynchrony
title Extratympanic electrocochleography in the diagnosis of auditory neuropathy/auditory dyssynchrony
title_full Extratympanic electrocochleography in the diagnosis of auditory neuropathy/auditory dyssynchrony
title_fullStr Extratympanic electrocochleography in the diagnosis of auditory neuropathy/auditory dyssynchrony
title_full_unstemmed Extratympanic electrocochleography in the diagnosis of auditory neuropathy/auditory dyssynchrony
title_short Extratympanic electrocochleography in the diagnosis of auditory neuropathy/auditory dyssynchrony
title_sort extratympanic electrocochleography in the diagnosis of auditory neuropathy/auditory dyssynchrony
topic Review Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9450606/
https://www.ncbi.nlm.nih.gov/pubmed/18392514
http://dx.doi.org/10.1016/S1808-8694(15)30763-1
work_keys_str_mv AT anastasioadrianaribeirotavares extratympanicelectrocochleographyinthediagnosisofauditoryneuropathyauditorydyssynchrony
AT alvarengakatiadefreitas extratympanicelectrocochleographyinthediagnosisofauditoryneuropathyauditorydyssynchrony
AT filhoorozimboalvescosta extratympanicelectrocochleographyinthediagnosisofauditoryneuropathyauditorydyssynchrony