Cargando…
Estimating the Ideal Treatment Protocol and Success Predictors for Double-session Micropulse Transscleral Laser for Glaucoma Management
AIM: To identify the ideal treatment protocol and success predictors for double-session micropulse transscleral (MP3) laser for glaucoma management. MATERIALS AND METHODS: Patients who underwent double-session MP3, with a minimum follow-up of 6 months, were retrospectively investigated. Logistic reg...
Autores principales: | , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Jaypee Brothers Medical Publishers
2022
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9452711/ https://www.ncbi.nlm.nih.gov/pubmed/36128079 http://dx.doi.org/10.5005/jp-journals-10078-1375 |
_version_ | 1784784970977378304 |
---|---|
author | Magacho, Leopoldo Lima, Francisco E Ávila, Marcos P |
author_facet | Magacho, Leopoldo Lima, Francisco E Ávila, Marcos P |
author_sort | Magacho, Leopoldo |
collection | PubMed |
description | AIM: To identify the ideal treatment protocol and success predictors for double-session micropulse transscleral (MP3) laser for glaucoma management. MATERIALS AND METHODS: Patients who underwent double-session MP3, with a minimum follow-up of 6 months, were retrospectively investigated. Logistic regression analysis was used to verify preoperative success predictors. The following comparisons were made: (1) Between eyes that obtained surgical success vs failure, (2) According to the time required for MP3, and (3) Considering only eyes that required retreatment. RESULTS: A total of 191 eyes from 148 patients were included. The preoperative intraocular pressure (IOP) was significantly higher than at last follow-up visit (27.3 ± 6.9 vs 14.6 ± 6.0 mm Hg, p < 0.001). Success was observed in 90.5% of the eyes. On logistic regression analysis with preoperative IOP and MP3 time as independent variables, only previous IOP was identified as a statistically significant factor (p = 0.004), with lower IOP relating to higher success. Eyes that required lower MP3 time underwent more MP3 procedures than those with higher MP3 time (1.2 ± 0.5 vs 1.1 ± 0.3, p = 0.03). In the 36 eyes that underwent retreatment, preoperative IOP was higher (31.6 ± 7.4 vs 26.3 ± 6.4 mm Hg, p < 0.001); eyes with successful IOP treatment had a higher MP3 treatment time at the first surgery than eyes with failed IOP correction (364.1 ± 68.2 vs 330.0 ± 18.0 seconds, p = 0.02). CONCLUSION: Thus, an ideal double-session MP3 protocol should use a high laser energy at the first surgery, and a high preoperative IOP can be considered as a predictor of surgical failure. CLINICAL SIGNIFICANCE: This is the first study to give special attention to the double-session MP3 protocol and success predictors. HOW TO CITE THIS ARTICLE: Magacho L, Lima FE, Ávila MP. Estimating the Ideal Treatment Protocol and Success Predictors for Double-session Micropulse Transscleral Laser for Glaucoma Management. J Curr Glaucoma Pract 2022;16(2):111-116. |
format | Online Article Text |
id | pubmed-9452711 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2022 |
publisher | Jaypee Brothers Medical Publishers |
record_format | MEDLINE/PubMed |
spelling | pubmed-94527112022-09-19 Estimating the Ideal Treatment Protocol and Success Predictors for Double-session Micropulse Transscleral Laser for Glaucoma Management Magacho, Leopoldo Lima, Francisco E Ávila, Marcos P J Curr Glaucoma Pract Original Research AIM: To identify the ideal treatment protocol and success predictors for double-session micropulse transscleral (MP3) laser for glaucoma management. MATERIALS AND METHODS: Patients who underwent double-session MP3, with a minimum follow-up of 6 months, were retrospectively investigated. Logistic regression analysis was used to verify preoperative success predictors. The following comparisons were made: (1) Between eyes that obtained surgical success vs failure, (2) According to the time required for MP3, and (3) Considering only eyes that required retreatment. RESULTS: A total of 191 eyes from 148 patients were included. The preoperative intraocular pressure (IOP) was significantly higher than at last follow-up visit (27.3 ± 6.9 vs 14.6 ± 6.0 mm Hg, p < 0.001). Success was observed in 90.5% of the eyes. On logistic regression analysis with preoperative IOP and MP3 time as independent variables, only previous IOP was identified as a statistically significant factor (p = 0.004), with lower IOP relating to higher success. Eyes that required lower MP3 time underwent more MP3 procedures than those with higher MP3 time (1.2 ± 0.5 vs 1.1 ± 0.3, p = 0.03). In the 36 eyes that underwent retreatment, preoperative IOP was higher (31.6 ± 7.4 vs 26.3 ± 6.4 mm Hg, p < 0.001); eyes with successful IOP treatment had a higher MP3 treatment time at the first surgery than eyes with failed IOP correction (364.1 ± 68.2 vs 330.0 ± 18.0 seconds, p = 0.02). CONCLUSION: Thus, an ideal double-session MP3 protocol should use a high laser energy at the first surgery, and a high preoperative IOP can be considered as a predictor of surgical failure. CLINICAL SIGNIFICANCE: This is the first study to give special attention to the double-session MP3 protocol and success predictors. HOW TO CITE THIS ARTICLE: Magacho L, Lima FE, Ávila MP. Estimating the Ideal Treatment Protocol and Success Predictors for Double-session Micropulse Transscleral Laser for Glaucoma Management. J Curr Glaucoma Pract 2022;16(2):111-116. Jaypee Brothers Medical Publishers 2022 /pmc/articles/PMC9452711/ /pubmed/36128079 http://dx.doi.org/10.5005/jp-journals-10078-1375 Text en Copyright © 2022; The Author(s). https://creativecommons.org/licenses/by-nc/4.0/© The Author(s). 2022 Open Access This article is distributed under the terms of the Creative Commons Attribution 4.0 International License (https://creativecommons.org/licenses/by-nc/4.0/), which permits unrestricted use, distribution, and non-commercial reproduction in any medium, provided you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons license, and indicate if changes were made. The Creative Commons Public Domain Dedication waiver (http://creativecommons.org/publicdomain/zero/1.0/ (https://creativecommons.org/publicdomain/zero/1.0/) ) applies to the data made available in this article, unless otherwise stated. |
spellingShingle | Original Research Magacho, Leopoldo Lima, Francisco E Ávila, Marcos P Estimating the Ideal Treatment Protocol and Success Predictors for Double-session Micropulse Transscleral Laser for Glaucoma Management |
title | Estimating the Ideal Treatment Protocol and Success Predictors for Double-session Micropulse Transscleral Laser for Glaucoma Management |
title_full | Estimating the Ideal Treatment Protocol and Success Predictors for Double-session Micropulse Transscleral Laser for Glaucoma Management |
title_fullStr | Estimating the Ideal Treatment Protocol and Success Predictors for Double-session Micropulse Transscleral Laser for Glaucoma Management |
title_full_unstemmed | Estimating the Ideal Treatment Protocol and Success Predictors for Double-session Micropulse Transscleral Laser for Glaucoma Management |
title_short | Estimating the Ideal Treatment Protocol and Success Predictors for Double-session Micropulse Transscleral Laser for Glaucoma Management |
title_sort | estimating the ideal treatment protocol and success predictors for double-session micropulse transscleral laser for glaucoma management |
topic | Original Research |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9452711/ https://www.ncbi.nlm.nih.gov/pubmed/36128079 http://dx.doi.org/10.5005/jp-journals-10078-1375 |
work_keys_str_mv | AT magacholeopoldo estimatingtheidealtreatmentprotocolandsuccesspredictorsfordoublesessionmicropulsetranssclerallaserforglaucomamanagement AT limafranciscoe estimatingtheidealtreatmentprotocolandsuccesspredictorsfordoublesessionmicropulsetranssclerallaserforglaucomamanagement AT avilamarcosp estimatingtheidealtreatmentprotocolandsuccesspredictorsfordoublesessionmicropulsetranssclerallaserforglaucomamanagement |