Cargando…

Efficacy and Safety of iStent Inject Implantation in Manual and Femtosecond Laser-assisted Cataract Surgery before Lens Extraction

AIM: To describe the efficacy and safety of iStent implantation prior to phacoemulsification in manual as well as femtosecond laser-assisted cataract surgery (FLACS), and highlight this approach as a reasonable, if not necessary, step to advance one's ability and confidence in the use of microi...

Descripción completa

Detalles Bibliográficos
Autores principales: Manning, David Kevin, Haider, Ali, Clement, Colin, Viswanathan, Deepa
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Jaypee Brothers Medical Publishers 2022
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9452712/
https://www.ncbi.nlm.nih.gov/pubmed/36128086
http://dx.doi.org/10.5005/jp-journals-10078-1374
_version_ 1784784971229036544
author Manning, David Kevin
Haider, Ali
Clement, Colin
Viswanathan, Deepa
author_facet Manning, David Kevin
Haider, Ali
Clement, Colin
Viswanathan, Deepa
author_sort Manning, David Kevin
collection PubMed
description AIM: To describe the efficacy and safety of iStent implantation prior to phacoemulsification in manual as well as femtosecond laser-assisted cataract surgery (FLACS), and highlight this approach as a reasonable, if not necessary, step to advance one's ability and confidence in the use of microinvasive glaucoma surgery (MIGS) technology in phakic patients. METHODS: A retrospective consecutive case series of patients with open angle glaucoma or ocular hypertension who underwent iStent inject implantation followed by cataract surgery (manual or FLACS). All cases underwent postoperative video review and were assessed and classified for intraoperative lens injury and hyphaema. Postoperative data included intraocular pressure (IOP), medication usage and adverse events. RESULTS: Sixty-three eyes (n = 40 manual, n = 23 FLACS) were analyzed. Preoperatively, the mean IOP was 19.2 ± 4.9 mm Hg on 1.4 ± 0.96 mean medications, with 100% of eyes treated with medication. Intraoperatively, no lens injury was identified, and no significant hyphaema that impeded surgery occurred. At 6 months postoperative, mean IOP was 14.2 ± 1.8 mm Hg (38% reduction: p < 0.001), and >90% of eyes had IOP ≤ 16 mm Hg. The mean number of medications reduced to 0.11 ± 0.3 (92% reduction: p < 0.001), with 89% of eyes medication free. Safety was excellent for both manual and FLACS, with two iStents implanted in all eyes, and no cases of significant hyphaema or lens injury. CONCLUSION: Early implantation is safe, maximizes corneal clarity and angle visualization, avoids the risk of non-implantation due to surgical complications, and has a high success rate in both manual cataract surgery and the setting of FLACS. CLINICAL SIGNIFICANCE: The conventional recommended approach of iStent implantation following cataract extraction has been adopted by many, however, with the advent of stand-alone procedures and concern about potential lens injury, there is an opportunity to gain experience with minimal risk in patients undergoing MIGS procedures combined with cataract surgery by implanting iStents at the start of the procedure. There is currently little emphasis or data published in the literature on an early approach to implantation to guide surgeons. HOW TO CITE THIS ARTICLE: Manning DK, Haider A, Clement C, et al. Efficacy and Safety of iStent Inject Implantation in Manual and Femtosecond Laser-assisted Cataract Surgery before Lens Extraction. J Curr Glaucoma Pract 2022;16(2):105-110.
format Online
Article
Text
id pubmed-9452712
institution National Center for Biotechnology Information
language English
publishDate 2022
publisher Jaypee Brothers Medical Publishers
record_format MEDLINE/PubMed
spelling pubmed-94527122022-09-19 Efficacy and Safety of iStent Inject Implantation in Manual and Femtosecond Laser-assisted Cataract Surgery before Lens Extraction Manning, David Kevin Haider, Ali Clement, Colin Viswanathan, Deepa J Curr Glaucoma Pract Original Research AIM: To describe the efficacy and safety of iStent implantation prior to phacoemulsification in manual as well as femtosecond laser-assisted cataract surgery (FLACS), and highlight this approach as a reasonable, if not necessary, step to advance one's ability and confidence in the use of microinvasive glaucoma surgery (MIGS) technology in phakic patients. METHODS: A retrospective consecutive case series of patients with open angle glaucoma or ocular hypertension who underwent iStent inject implantation followed by cataract surgery (manual or FLACS). All cases underwent postoperative video review and were assessed and classified for intraoperative lens injury and hyphaema. Postoperative data included intraocular pressure (IOP), medication usage and adverse events. RESULTS: Sixty-three eyes (n = 40 manual, n = 23 FLACS) were analyzed. Preoperatively, the mean IOP was 19.2 ± 4.9 mm Hg on 1.4 ± 0.96 mean medications, with 100% of eyes treated with medication. Intraoperatively, no lens injury was identified, and no significant hyphaema that impeded surgery occurred. At 6 months postoperative, mean IOP was 14.2 ± 1.8 mm Hg (38% reduction: p < 0.001), and >90% of eyes had IOP ≤ 16 mm Hg. The mean number of medications reduced to 0.11 ± 0.3 (92% reduction: p < 0.001), with 89% of eyes medication free. Safety was excellent for both manual and FLACS, with two iStents implanted in all eyes, and no cases of significant hyphaema or lens injury. CONCLUSION: Early implantation is safe, maximizes corneal clarity and angle visualization, avoids the risk of non-implantation due to surgical complications, and has a high success rate in both manual cataract surgery and the setting of FLACS. CLINICAL SIGNIFICANCE: The conventional recommended approach of iStent implantation following cataract extraction has been adopted by many, however, with the advent of stand-alone procedures and concern about potential lens injury, there is an opportunity to gain experience with minimal risk in patients undergoing MIGS procedures combined with cataract surgery by implanting iStents at the start of the procedure. There is currently little emphasis or data published in the literature on an early approach to implantation to guide surgeons. HOW TO CITE THIS ARTICLE: Manning DK, Haider A, Clement C, et al. Efficacy and Safety of iStent Inject Implantation in Manual and Femtosecond Laser-assisted Cataract Surgery before Lens Extraction. J Curr Glaucoma Pract 2022;16(2):105-110. Jaypee Brothers Medical Publishers 2022 /pmc/articles/PMC9452712/ /pubmed/36128086 http://dx.doi.org/10.5005/jp-journals-10078-1374 Text en Copyright © 2022; The Author(s). https://creativecommons.org/licenses/by-nc/4.0/© The Author(s). 2022 Open Access This article is distributed under the terms of the Creative Commons Attribution 4.0 International License (https://creativecommons.org/licenses/by-nc/4.0/), which permits unrestricted use, distribution, and non-commercial reproduction in any medium, provided you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons license, and indicate if changes were made. The Creative Commons Public Domain Dedication waiver (http://creativecommons.org/publicdomain/zero/1.0/ (https://creativecommons.org/publicdomain/zero/1.0/) ) applies to the data made available in this article, unless otherwise stated.
spellingShingle Original Research
Manning, David Kevin
Haider, Ali
Clement, Colin
Viswanathan, Deepa
Efficacy and Safety of iStent Inject Implantation in Manual and Femtosecond Laser-assisted Cataract Surgery before Lens Extraction
title Efficacy and Safety of iStent Inject Implantation in Manual and Femtosecond Laser-assisted Cataract Surgery before Lens Extraction
title_full Efficacy and Safety of iStent Inject Implantation in Manual and Femtosecond Laser-assisted Cataract Surgery before Lens Extraction
title_fullStr Efficacy and Safety of iStent Inject Implantation in Manual and Femtosecond Laser-assisted Cataract Surgery before Lens Extraction
title_full_unstemmed Efficacy and Safety of iStent Inject Implantation in Manual and Femtosecond Laser-assisted Cataract Surgery before Lens Extraction
title_short Efficacy and Safety of iStent Inject Implantation in Manual and Femtosecond Laser-assisted Cataract Surgery before Lens Extraction
title_sort efficacy and safety of istent inject implantation in manual and femtosecond laser-assisted cataract surgery before lens extraction
topic Original Research
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9452712/
https://www.ncbi.nlm.nih.gov/pubmed/36128086
http://dx.doi.org/10.5005/jp-journals-10078-1374
work_keys_str_mv AT manningdavidkevin efficacyandsafetyofistentinjectimplantationinmanualandfemtosecondlaserassistedcataractsurgerybeforelensextraction
AT haiderali efficacyandsafetyofistentinjectimplantationinmanualandfemtosecondlaserassistedcataractsurgerybeforelensextraction
AT clementcolin efficacyandsafetyofistentinjectimplantationinmanualandfemtosecondlaserassistedcataractsurgerybeforelensextraction
AT viswanathandeepa efficacyandsafetyofistentinjectimplantationinmanualandfemtosecondlaserassistedcataractsurgerybeforelensextraction