Cargando…

Semen Quality Following Long-term Occupational Exposure to Formaldehyde in China

IMPORTANCE: The potential effects of long-term occupational exposure to formaldehyde (FA) on human semen quality is not clear. OBJECTIVE: To assess whether long-term occupational exposure to FA is associated with semen quality. DESIGN, SETTING, AND PARTICIPANTS: This population-based cohort study wa...

Descripción completa

Detalles Bibliográficos
Autores principales: Lv, Mo-qi, Wang, Hai-xu, Yang, Yan-qi, Sun, Rui-fang, Ge, Pan, Zhang, Jian, Zhao, Wen-bao, Han, Shui-ping, Zhou, Dang-xia
Formato: Online Artículo Texto
Lenguaje:English
Publicado: American Medical Association 2022
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9453542/
https://www.ncbi.nlm.nih.gov/pubmed/36069982
http://dx.doi.org/10.1001/jamanetworkopen.2022.30359
_version_ 1784785166625931264
author Lv, Mo-qi
Wang, Hai-xu
Yang, Yan-qi
Sun, Rui-fang
Ge, Pan
Zhang, Jian
Zhao, Wen-bao
Han, Shui-ping
Zhou, Dang-xia
author_facet Lv, Mo-qi
Wang, Hai-xu
Yang, Yan-qi
Sun, Rui-fang
Ge, Pan
Zhang, Jian
Zhao, Wen-bao
Han, Shui-ping
Zhou, Dang-xia
author_sort Lv, Mo-qi
collection PubMed
description IMPORTANCE: The potential effects of long-term occupational exposure to formaldehyde (FA) on human semen quality is not clear. OBJECTIVE: To assess whether long-term occupational exposure to FA is associated with semen quality. DESIGN, SETTING, AND PARTICIPANTS: This population-based cohort study was conducted from June 1 to June 30, 2021, in Xi’an, China. Participants were adults aged 23 to 40 years who had lived in the study area for 24 months or longer. Data analysis was performed from September 1 to October 1, 2021. EXPOSURES: Long-term occupational exposure to FA was measured using a formaldehyde detector, and the FA exposure index (FEI) was calculated as follows: FEI = final concentration of FA (mg/m(3)) × work time during a workday (hour) × cumulative workdays (year). MAIN OUTCOMES AND MEASURES: Semen samples were collected by masturbation after 3 to 7 days of abstinence and were then assessed by the computer-automated semen analysis system, Baso-Papanicolaou staining, and sperm-chromatin structure assay. RESULTS: A total of 205 men (mean [SD] age, 29.49 [3.64] years), with 124 individuals in the FA exposure group (mean [SD] FEI, 73.72 [54.86]) and 81 age-matched controls, were included in the final analysis. Long-term personal occupational exposure to FA was significantly associated with poor semen quality. Specifically, a 1-unit increase in FEI was associated with a change of −0.99% (95% CI, −1.00% to −0.98%) in total sperm motility, −0.99% (95% CI, −0.99% to −0.97%) in progressive sperm motility, −0.05% (95% CI, −0.08% to −0.02%) in curvilinear velocity, −0.07% (95% CI, −0.10% to −0.04%) in straight line velocity, −0.07% (95% CI, −0.10% to −0.04%) in time-average velocity, −0.98% (95% CI, −0.99% to −0.93%) in normal sperm morphology, −0.24% (95% CI, −0.35% to −0.11%) in seminal neutral glucosidase, −0.61% (95% CI, −0.66% to −0.56%) in seminal plasma zinc, 0.52% (95% CI, 0.15% to 1.02%) in beat cross frequency, and 0.10% (95% CI, 0.06% to 0.14%) in the DNA fragmentation index. These associations remained significant after adjusting for confounding factors. Furthermore, subgroup analysis found that high levels of oxidative stress might promote the associations between FA exposure and semen quality. CONCLUSIONS AND RELEVANCE: This study found an association between long-term occupational exposure to FA and semen quality. This deterioration was dose and time dependent and might be induced by oxidative stress.
format Online
Article
Text
id pubmed-9453542
institution National Center for Biotechnology Information
language English
publishDate 2022
publisher American Medical Association
record_format MEDLINE/PubMed
spelling pubmed-94535422022-09-24 Semen Quality Following Long-term Occupational Exposure to Formaldehyde in China Lv, Mo-qi Wang, Hai-xu Yang, Yan-qi Sun, Rui-fang Ge, Pan Zhang, Jian Zhao, Wen-bao Han, Shui-ping Zhou, Dang-xia JAMA Netw Open Original Investigation IMPORTANCE: The potential effects of long-term occupational exposure to formaldehyde (FA) on human semen quality is not clear. OBJECTIVE: To assess whether long-term occupational exposure to FA is associated with semen quality. DESIGN, SETTING, AND PARTICIPANTS: This population-based cohort study was conducted from June 1 to June 30, 2021, in Xi’an, China. Participants were adults aged 23 to 40 years who had lived in the study area for 24 months or longer. Data analysis was performed from September 1 to October 1, 2021. EXPOSURES: Long-term occupational exposure to FA was measured using a formaldehyde detector, and the FA exposure index (FEI) was calculated as follows: FEI = final concentration of FA (mg/m(3)) × work time during a workday (hour) × cumulative workdays (year). MAIN OUTCOMES AND MEASURES: Semen samples were collected by masturbation after 3 to 7 days of abstinence and were then assessed by the computer-automated semen analysis system, Baso-Papanicolaou staining, and sperm-chromatin structure assay. RESULTS: A total of 205 men (mean [SD] age, 29.49 [3.64] years), with 124 individuals in the FA exposure group (mean [SD] FEI, 73.72 [54.86]) and 81 age-matched controls, were included in the final analysis. Long-term personal occupational exposure to FA was significantly associated with poor semen quality. Specifically, a 1-unit increase in FEI was associated with a change of −0.99% (95% CI, −1.00% to −0.98%) in total sperm motility, −0.99% (95% CI, −0.99% to −0.97%) in progressive sperm motility, −0.05% (95% CI, −0.08% to −0.02%) in curvilinear velocity, −0.07% (95% CI, −0.10% to −0.04%) in straight line velocity, −0.07% (95% CI, −0.10% to −0.04%) in time-average velocity, −0.98% (95% CI, −0.99% to −0.93%) in normal sperm morphology, −0.24% (95% CI, −0.35% to −0.11%) in seminal neutral glucosidase, −0.61% (95% CI, −0.66% to −0.56%) in seminal plasma zinc, 0.52% (95% CI, 0.15% to 1.02%) in beat cross frequency, and 0.10% (95% CI, 0.06% to 0.14%) in the DNA fragmentation index. These associations remained significant after adjusting for confounding factors. Furthermore, subgroup analysis found that high levels of oxidative stress might promote the associations between FA exposure and semen quality. CONCLUSIONS AND RELEVANCE: This study found an association between long-term occupational exposure to FA and semen quality. This deterioration was dose and time dependent and might be induced by oxidative stress. American Medical Association 2022-09-07 /pmc/articles/PMC9453542/ /pubmed/36069982 http://dx.doi.org/10.1001/jamanetworkopen.2022.30359 Text en Copyright 2022 Lv MQ et al. JAMA Network Open. https://creativecommons.org/licenses/by/4.0/This is an open access article distributed under the terms of the CC-BY License.
spellingShingle Original Investigation
Lv, Mo-qi
Wang, Hai-xu
Yang, Yan-qi
Sun, Rui-fang
Ge, Pan
Zhang, Jian
Zhao, Wen-bao
Han, Shui-ping
Zhou, Dang-xia
Semen Quality Following Long-term Occupational Exposure to Formaldehyde in China
title Semen Quality Following Long-term Occupational Exposure to Formaldehyde in China
title_full Semen Quality Following Long-term Occupational Exposure to Formaldehyde in China
title_fullStr Semen Quality Following Long-term Occupational Exposure to Formaldehyde in China
title_full_unstemmed Semen Quality Following Long-term Occupational Exposure to Formaldehyde in China
title_short Semen Quality Following Long-term Occupational Exposure to Formaldehyde in China
title_sort semen quality following long-term occupational exposure to formaldehyde in china
topic Original Investigation
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9453542/
https://www.ncbi.nlm.nih.gov/pubmed/36069982
http://dx.doi.org/10.1001/jamanetworkopen.2022.30359
work_keys_str_mv AT lvmoqi semenqualityfollowinglongtermoccupationalexposuretoformaldehydeinchina
AT wanghaixu semenqualityfollowinglongtermoccupationalexposuretoformaldehydeinchina
AT yangyanqi semenqualityfollowinglongtermoccupationalexposuretoformaldehydeinchina
AT sunruifang semenqualityfollowinglongtermoccupationalexposuretoformaldehydeinchina
AT gepan semenqualityfollowinglongtermoccupationalexposuretoformaldehydeinchina
AT zhangjian semenqualityfollowinglongtermoccupationalexposuretoformaldehydeinchina
AT zhaowenbao semenqualityfollowinglongtermoccupationalexposuretoformaldehydeinchina
AT hanshuiping semenqualityfollowinglongtermoccupationalexposuretoformaldehydeinchina
AT zhoudangxia semenqualityfollowinglongtermoccupationalexposuretoformaldehydeinchina