Underivatized Amino Acid Chromatographic Separation: Optimized Conditions for HPLC-UV Simultaneous Quantification of Isoleucine, Leucine, Lysine, Threonine, Histidine, Valine, Methionine, Phenylalanine, Tryptophan, and Tyrosine in Dietary Supplements

[Image: see text] Amino acids (AAs) are considered as the building blocks of life. Unlike nonessential AAs, the human body cannot synthesize essential AAs and should be supplied in food or dietary supplements. The aim of the work is simultaneous HPLC-UV determination of 10 structurally related AAs w...

Descripción completa

Detalles Bibliográficos
Autores principales: Eid, Sherif M., Farag, Mohamed A., Bawazeer, Sami
Formato: Online Artículo Texto
Lenguaje:English
Publicado: American Chemical Society 2022
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9453785/
https://www.ncbi.nlm.nih.gov/pubmed/36092579
http://dx.doi.org/10.1021/acsomega.2c03228
_version_ 1784785215842942976
author Eid, Sherif M.
Farag, Mohamed A.
Bawazeer, Sami
author_facet Eid, Sherif M.
Farag, Mohamed A.
Bawazeer, Sami
author_sort Eid, Sherif M.
collection PubMed
description [Image: see text] Amino acids (AAs) are considered as the building blocks of life. Unlike nonessential AAs, the human body cannot synthesize essential AAs and should be supplied in food or dietary supplements. The aim of the work is simultaneous HPLC-UV determination of 10 structurally related AAs without pre- or postderivatization in powdered dietary supplements (PDSs). This was challenging, especially because PDS has no standardized procedures for its quality control. HPLC-UV chromatograms of the 10 AAs were recorded using a gradient elution of the mobile phase on a CLC-C18 column at 225 nm. The elution started with 100% of phosphate buffer (pH 7.4, 10 mM) for 10 min; then, the concentration of acetonitrile increased linearly to reach 50% for another 15 min at room temperature. Good separation was achieved within a 25 min run time without pre- or postderivatization. The method was carefully validated according to the ICH guidelines over the linearity range of 100–200, 50–200, 20–150, 50–400, 20–250, 75–175, 50–250, 50–250, 50–300, and 5–100 μg/mL for l-lysine, l-threonine, l-histidine, l-valine, l-methionine, l-isoleucine, l-leucine, l-tyrosine, l-phenylalanine, and l-tryptophan, respectively, with mean recoveries ranges between 98.91 and 100.77. The method was found to be precise, and the relative standard deviation (RSD) was found to be between 0.28 and 1.92 with recoveries between 97.91 and 101.11. The method was found to be robust that resists deliberate changes in pH, flow rate, and mobile-phase percentages. It was successfully applied for the analysis of PDSs. The proposed method could be very useful for the quality control of the 10 structurally related AAs during their synthesis and for testing raw materials and pharmaceutical preparations.
format Online
Article
Text
id pubmed-9453785
institution National Center for Biotechnology Information
language English
publishDate 2022
publisher American Chemical Society
record_format MEDLINE/PubMed
spelling pubmed-94537852022-09-09 Underivatized Amino Acid Chromatographic Separation: Optimized Conditions for HPLC-UV Simultaneous Quantification of Isoleucine, Leucine, Lysine, Threonine, Histidine, Valine, Methionine, Phenylalanine, Tryptophan, and Tyrosine in Dietary Supplements Eid, Sherif M. Farag, Mohamed A. Bawazeer, Sami ACS Omega [Image: see text] Amino acids (AAs) are considered as the building blocks of life. Unlike nonessential AAs, the human body cannot synthesize essential AAs and should be supplied in food or dietary supplements. The aim of the work is simultaneous HPLC-UV determination of 10 structurally related AAs without pre- or postderivatization in powdered dietary supplements (PDSs). This was challenging, especially because PDS has no standardized procedures for its quality control. HPLC-UV chromatograms of the 10 AAs were recorded using a gradient elution of the mobile phase on a CLC-C18 column at 225 nm. The elution started with 100% of phosphate buffer (pH 7.4, 10 mM) for 10 min; then, the concentration of acetonitrile increased linearly to reach 50% for another 15 min at room temperature. Good separation was achieved within a 25 min run time without pre- or postderivatization. The method was carefully validated according to the ICH guidelines over the linearity range of 100–200, 50–200, 20–150, 50–400, 20–250, 75–175, 50–250, 50–250, 50–300, and 5–100 μg/mL for l-lysine, l-threonine, l-histidine, l-valine, l-methionine, l-isoleucine, l-leucine, l-tyrosine, l-phenylalanine, and l-tryptophan, respectively, with mean recoveries ranges between 98.91 and 100.77. The method was found to be precise, and the relative standard deviation (RSD) was found to be between 0.28 and 1.92 with recoveries between 97.91 and 101.11. The method was found to be robust that resists deliberate changes in pH, flow rate, and mobile-phase percentages. It was successfully applied for the analysis of PDSs. The proposed method could be very useful for the quality control of the 10 structurally related AAs during their synthesis and for testing raw materials and pharmaceutical preparations. American Chemical Society 2022-08-11 /pmc/articles/PMC9453785/ /pubmed/36092579 http://dx.doi.org/10.1021/acsomega.2c03228 Text en © 2022 The Authors. Published by American Chemical Society https://creativecommons.org/licenses/by-nc-nd/4.0/Permits non-commercial access and re-use, provided that author attribution and integrity are maintained; but does not permit creation of adaptations or other derivative works (https://creativecommons.org/licenses/by-nc-nd/4.0/).
spellingShingle Eid, Sherif M.
Farag, Mohamed A.
Bawazeer, Sami
Underivatized Amino Acid Chromatographic Separation: Optimized Conditions for HPLC-UV Simultaneous Quantification of Isoleucine, Leucine, Lysine, Threonine, Histidine, Valine, Methionine, Phenylalanine, Tryptophan, and Tyrosine in Dietary Supplements
title Underivatized Amino Acid Chromatographic Separation: Optimized Conditions for HPLC-UV Simultaneous Quantification of Isoleucine, Leucine, Lysine, Threonine, Histidine, Valine, Methionine, Phenylalanine, Tryptophan, and Tyrosine in Dietary Supplements
title_full Underivatized Amino Acid Chromatographic Separation: Optimized Conditions for HPLC-UV Simultaneous Quantification of Isoleucine, Leucine, Lysine, Threonine, Histidine, Valine, Methionine, Phenylalanine, Tryptophan, and Tyrosine in Dietary Supplements
title_fullStr Underivatized Amino Acid Chromatographic Separation: Optimized Conditions for HPLC-UV Simultaneous Quantification of Isoleucine, Leucine, Lysine, Threonine, Histidine, Valine, Methionine, Phenylalanine, Tryptophan, and Tyrosine in Dietary Supplements
title_full_unstemmed Underivatized Amino Acid Chromatographic Separation: Optimized Conditions for HPLC-UV Simultaneous Quantification of Isoleucine, Leucine, Lysine, Threonine, Histidine, Valine, Methionine, Phenylalanine, Tryptophan, and Tyrosine in Dietary Supplements
title_short Underivatized Amino Acid Chromatographic Separation: Optimized Conditions for HPLC-UV Simultaneous Quantification of Isoleucine, Leucine, Lysine, Threonine, Histidine, Valine, Methionine, Phenylalanine, Tryptophan, and Tyrosine in Dietary Supplements
title_sort underivatized amino acid chromatographic separation: optimized conditions for hplc-uv simultaneous quantification of isoleucine, leucine, lysine, threonine, histidine, valine, methionine, phenylalanine, tryptophan, and tyrosine in dietary supplements
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9453785/
https://www.ncbi.nlm.nih.gov/pubmed/36092579
http://dx.doi.org/10.1021/acsomega.2c03228
work_keys_str_mv AT eidsherifm underivatizedaminoacidchromatographicseparationoptimizedconditionsforhplcuvsimultaneousquantificationofisoleucineleucinelysinethreoninehistidinevalinemethioninephenylalaninetryptophanandtyrosineindietarysupplements
AT faragmohameda underivatizedaminoacidchromatographicseparationoptimizedconditionsforhplcuvsimultaneousquantificationofisoleucineleucinelysinethreoninehistidinevalinemethioninephenylalaninetryptophanandtyrosineindietarysupplements
AT bawazeersami underivatizedaminoacidchromatographicseparationoptimizedconditionsforhplcuvsimultaneousquantificationofisoleucineleucinelysinethreoninehistidinevalinemethioninephenylalaninetryptophanandtyrosineindietarysupplements