Cargando…

Implantable collamer lens sizing based on measurement of the sulcus-to-sulcus distance in ultrasound biomicroscopy video clips and ZZ ICL formula

BACKGROUND: To evaluate a new method of implantable collamer lens (ICL) sizing based on ultrasound biomicroscopy (UBM) video clips. METHODS: This observational study included consecutive patients with myopia and myopic astigmatism scheduled for V4c toric ICL (TICL) implantation (STAAR) at Hangzhou M...

Descripción completa

Detalles Bibliográficos
Autores principales: Zhang, Jun, Shao, Jie, Zheng, Li, Zhao, Xia, Chen, Shu
Formato: Online Artículo Texto
Lenguaje:English
Publicado: BioMed Central 2022
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9454160/
https://www.ncbi.nlm.nih.gov/pubmed/36071422
http://dx.doi.org/10.1186/s12886-022-02583-9
_version_ 1784785291704270848
author Zhang, Jun
Shao, Jie
Zheng, Li
Zhao, Xia
Chen, Shu
author_facet Zhang, Jun
Shao, Jie
Zheng, Li
Zhao, Xia
Chen, Shu
author_sort Zhang, Jun
collection PubMed
description BACKGROUND: To evaluate a new method of implantable collamer lens (ICL) sizing based on ultrasound biomicroscopy (UBM) video clips. METHODS: This observational study included consecutive patients with myopia and myopic astigmatism scheduled for V4c toric ICL (TICL) implantation (STAAR) at Hangzhou MSK Eye Hospital (October 2020 to November 2020). Sulcus-to-sulcus (STS) distance, lens thickness (LT), and clinical refraction were measured preoperatively. The ZZ ICL formula (provides the predicted vault height and refraction based on TICL size, intraocular meridian, power, and eye parameters, including STS distance and LT) was used to select TICL size and predict vault height and residual refraction, which was also compared with the STAAR software recommended. Vault and residual refraction were measured at 3 months postoperatively. RESULTS: The analysis included 168 eyes in 84 patients. Postoperative vault size was comparable to that predicted by the ZZ ICL formula (528 ± 193 vs. 545 ± 156 μm, P = 0.227). Vault prediction error (PE) by the ZZ ICL formula was within 100, 300, and 500 μm in 40.48%, 88.10%, and 100% of eyes, respectively. Spherical equivalent (SE) and absolute cylindrical refractive error were 0.36 ± 0.48 and 0.40 ± 0.31 D at 3 months postoperatively. The SE PE, absolute cylindrical PE, and percentages of eyes with an absolute cylindrical PE within ± 0.50 D and ± 1.00 D were lower for the ZZ ICL formula than for the STAAR software (P < 0.01). CONCLUSIONS: Combining measurements obtained in UBM video clips with the ZZ ICL formula provides an effective method of sizing TICLs and predicting vault height and residual refractive error. SUPPLEMENTARY INFORMATION: The online version contains supplementary material available at 10.1186/s12886-022-02583-9.
format Online
Article
Text
id pubmed-9454160
institution National Center for Biotechnology Information
language English
publishDate 2022
publisher BioMed Central
record_format MEDLINE/PubMed
spelling pubmed-94541602022-09-09 Implantable collamer lens sizing based on measurement of the sulcus-to-sulcus distance in ultrasound biomicroscopy video clips and ZZ ICL formula Zhang, Jun Shao, Jie Zheng, Li Zhao, Xia Chen, Shu BMC Ophthalmol Research BACKGROUND: To evaluate a new method of implantable collamer lens (ICL) sizing based on ultrasound biomicroscopy (UBM) video clips. METHODS: This observational study included consecutive patients with myopia and myopic astigmatism scheduled for V4c toric ICL (TICL) implantation (STAAR) at Hangzhou MSK Eye Hospital (October 2020 to November 2020). Sulcus-to-sulcus (STS) distance, lens thickness (LT), and clinical refraction were measured preoperatively. The ZZ ICL formula (provides the predicted vault height and refraction based on TICL size, intraocular meridian, power, and eye parameters, including STS distance and LT) was used to select TICL size and predict vault height and residual refraction, which was also compared with the STAAR software recommended. Vault and residual refraction were measured at 3 months postoperatively. RESULTS: The analysis included 168 eyes in 84 patients. Postoperative vault size was comparable to that predicted by the ZZ ICL formula (528 ± 193 vs. 545 ± 156 μm, P = 0.227). Vault prediction error (PE) by the ZZ ICL formula was within 100, 300, and 500 μm in 40.48%, 88.10%, and 100% of eyes, respectively. Spherical equivalent (SE) and absolute cylindrical refractive error were 0.36 ± 0.48 and 0.40 ± 0.31 D at 3 months postoperatively. The SE PE, absolute cylindrical PE, and percentages of eyes with an absolute cylindrical PE within ± 0.50 D and ± 1.00 D were lower for the ZZ ICL formula than for the STAAR software (P < 0.01). CONCLUSIONS: Combining measurements obtained in UBM video clips with the ZZ ICL formula provides an effective method of sizing TICLs and predicting vault height and residual refractive error. SUPPLEMENTARY INFORMATION: The online version contains supplementary material available at 10.1186/s12886-022-02583-9. BioMed Central 2022-09-07 /pmc/articles/PMC9454160/ /pubmed/36071422 http://dx.doi.org/10.1186/s12886-022-02583-9 Text en © The Author(s) 2022 https://creativecommons.org/licenses/by/4.0/Open AccessThis article is licensed under a Creative Commons Attribution 4.0 International License, which permits use, sharing, adaptation, distribution and reproduction in any medium or format, as long as you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons licence, and indicate if changes were made. The images or other third party material in this article are included in the article's Creative Commons licence, unless indicated otherwise in a credit line to the material. If material is not included in the article's Creative Commons licence and your intended use is not permitted by statutory regulation or exceeds the permitted use, you will need to obtain permission directly from the copyright holder. To view a copy of this licence, visit http://creativecommons.org/licenses/by/4.0/ (https://creativecommons.org/licenses/by/4.0/) . The Creative Commons Public Domain Dedication waiver (http://creativecommons.org/publicdomain/zero/1.0/ (https://creativecommons.org/publicdomain/zero/1.0/) ) applies to the data made available in this article, unless otherwise stated in a credit line to the data.
spellingShingle Research
Zhang, Jun
Shao, Jie
Zheng, Li
Zhao, Xia
Chen, Shu
Implantable collamer lens sizing based on measurement of the sulcus-to-sulcus distance in ultrasound biomicroscopy video clips and ZZ ICL formula
title Implantable collamer lens sizing based on measurement of the sulcus-to-sulcus distance in ultrasound biomicroscopy video clips and ZZ ICL formula
title_full Implantable collamer lens sizing based on measurement of the sulcus-to-sulcus distance in ultrasound biomicroscopy video clips and ZZ ICL formula
title_fullStr Implantable collamer lens sizing based on measurement of the sulcus-to-sulcus distance in ultrasound biomicroscopy video clips and ZZ ICL formula
title_full_unstemmed Implantable collamer lens sizing based on measurement of the sulcus-to-sulcus distance in ultrasound biomicroscopy video clips and ZZ ICL formula
title_short Implantable collamer lens sizing based on measurement of the sulcus-to-sulcus distance in ultrasound biomicroscopy video clips and ZZ ICL formula
title_sort implantable collamer lens sizing based on measurement of the sulcus-to-sulcus distance in ultrasound biomicroscopy video clips and zz icl formula
topic Research
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9454160/
https://www.ncbi.nlm.nih.gov/pubmed/36071422
http://dx.doi.org/10.1186/s12886-022-02583-9
work_keys_str_mv AT zhangjun implantablecollamerlenssizingbasedonmeasurementofthesulcustosulcusdistanceinultrasoundbiomicroscopyvideoclipsandzziclformula
AT shaojie implantablecollamerlenssizingbasedonmeasurementofthesulcustosulcusdistanceinultrasoundbiomicroscopyvideoclipsandzziclformula
AT zhengli implantablecollamerlenssizingbasedonmeasurementofthesulcustosulcusdistanceinultrasoundbiomicroscopyvideoclipsandzziclformula
AT zhaoxia implantablecollamerlenssizingbasedonmeasurementofthesulcustosulcusdistanceinultrasoundbiomicroscopyvideoclipsandzziclformula
AT chenshu implantablecollamerlenssizingbasedonmeasurementofthesulcustosulcusdistanceinultrasoundbiomicroscopyvideoclipsandzziclformula