Cargando…

Establishing a novel model of malignant airway stenosis in rabbit

BACKGROUND: Malignant central airway stenosis is a life-threatening condition. However, treatment of malignant airway stenosis remains challenging. There is currently a severe lack of an excellent animal model of malignant airway stenosis to facilitate treatment approaches. This is the first study t...

Descripción completa

Detalles Bibliográficos
Autores principales: Lin, Xiaoxiao, Zhou, Liqin, Zhou, Wanting, Li, Yuping, Jin, Xuru, Ye, Min, Chen, Chengshui
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Frontiers Media S.A. 2022
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9454335/
https://www.ncbi.nlm.nih.gov/pubmed/36091165
http://dx.doi.org/10.3389/fonc.2022.959309
Descripción
Sumario:BACKGROUND: Malignant central airway stenosis is a life-threatening condition. However, treatment of malignant airway stenosis remains challenging. There is currently a severe lack of an excellent animal model of malignant airway stenosis to facilitate treatment approaches. This is the first study to establish a rabbit model of malignant airway stenosis for bronchoscopic interventional studies. MATERIALS AND METHODS: New Zealand White rabbits were used in this study, randomly divided into group A (18 rabbits) and group B (6 rabbits). A VX2 fragment suspension was injected into the submucosal layer of rabbits’ airway by bronchoscopy. Bronchoscopic examinations were performed once a week after VX2 tumor implantation to observe tumor growth and the degree of airway stenosis. Randomly, three rabbits were generally dissected after a weekly bronchoscopic examination in group A. The rabbits that reached grade III airway stenosis underwent stent implantation in group B. RESULTS: A total of 24 rabbits were successfully implanted with the VX2 fragment suspension in the airway without significant adverse events, and the success rate of the tumor growth was 100%. The degree of airway stenosis reaching grade III took 2 to 3 weeks after implantation of the VX2 tumor. The median survival time of rabbit models without stent implantation and rabbits with stent implantation was 32.5 and 32.0 days, respectively. CONCLUSIONS: The implanting method is safe and effective for the establishment of a rabbit model of malignant airway stenosis. When the tumor grows to 2 to 3 weeks, the rabbit model is available for stent implantation. We recommend the models for more preclinical animal studies on bronchoscopic interventional treatments.