Cargando…

A rapid and sensitive UPLC-MS/MS method for simultaneous determination of four potential mutagenic impurities at trace levels in ripretinib drug substance

In the synthesis of ripretinib, a new oral tyrosine kinase inhibitor, impurities could arise directly from starting materials, reagents and intermediates. Among these process impurities, four specific intermediate impurities were found to contain the structural alerts of primary aromatic amine and a...

Descripción completa

Detalles Bibliográficos
Autores principales: Huang, Yiwen, Xu, Qi, Lu, Hui, Li, Zhong, Wu, Yang
Formato: Online Artículo Texto
Lenguaje:English
Publicado: The Royal Society of Chemistry 2022
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9455223/
https://www.ncbi.nlm.nih.gov/pubmed/36199346
http://dx.doi.org/10.1039/d2ra04505b
_version_ 1784785534891065344
author Huang, Yiwen
Xu, Qi
Lu, Hui
Li, Zhong
Wu, Yang
author_facet Huang, Yiwen
Xu, Qi
Lu, Hui
Li, Zhong
Wu, Yang
author_sort Huang, Yiwen
collection PubMed
description In the synthesis of ripretinib, a new oral tyrosine kinase inhibitor, impurities could arise directly from starting materials, reagents and intermediates. Among these process impurities, four specific intermediate impurities were found to contain the structural alerts of primary aromatic amine and aldehyde groups, triggering the concern of potential mutagenic impurities (PMIs). Two complementary (quantitative) structure–activity relationship [(Q)SAR] evaluation systems (expert rule-based and statistics-based) were subsequently employed to assess and classify the mutagenic risk of the four known impurities. The Sarah prediction results of these four impurities were all positive and they were categorized as class 3, where the threshold of toxicological concern (TTC) of 1.5 μg d(−1) would apply. Hereby, a rapid and sensitive UPLC-MS/MS method was developed for the simultaneous and trace level quantification of the four PMIs in ripretinib drug substance. The separation was achieved on a C18 column under the optimized gradient elution program consuming only nine minutes and the four PMIs were all well separated from ripretinib so that they could be easily diverted to waste via a switch valve. The time-segmented multiple reaction monitoring (MRM) mode further improved the sensitivity and allowed for the quantification of the four PMIs as low as 10% of the acceptable limit. The method was fully validated, and proved sufficient in terms of selectivity, sensitivity, linearity, precision and accuracy. The factors involved in the method development and pathways for fragment ions of the four PMIs were also discussed and the study will contribute to risk management of PMIs present in ripretinib.
format Online
Article
Text
id pubmed-9455223
institution National Center for Biotechnology Information
language English
publishDate 2022
publisher The Royal Society of Chemistry
record_format MEDLINE/PubMed
spelling pubmed-94552232022-10-04 A rapid and sensitive UPLC-MS/MS method for simultaneous determination of four potential mutagenic impurities at trace levels in ripretinib drug substance Huang, Yiwen Xu, Qi Lu, Hui Li, Zhong Wu, Yang RSC Adv Chemistry In the synthesis of ripretinib, a new oral tyrosine kinase inhibitor, impurities could arise directly from starting materials, reagents and intermediates. Among these process impurities, four specific intermediate impurities were found to contain the structural alerts of primary aromatic amine and aldehyde groups, triggering the concern of potential mutagenic impurities (PMIs). Two complementary (quantitative) structure–activity relationship [(Q)SAR] evaluation systems (expert rule-based and statistics-based) were subsequently employed to assess and classify the mutagenic risk of the four known impurities. The Sarah prediction results of these four impurities were all positive and they were categorized as class 3, where the threshold of toxicological concern (TTC) of 1.5 μg d(−1) would apply. Hereby, a rapid and sensitive UPLC-MS/MS method was developed for the simultaneous and trace level quantification of the four PMIs in ripretinib drug substance. The separation was achieved on a C18 column under the optimized gradient elution program consuming only nine minutes and the four PMIs were all well separated from ripretinib so that they could be easily diverted to waste via a switch valve. The time-segmented multiple reaction monitoring (MRM) mode further improved the sensitivity and allowed for the quantification of the four PMIs as low as 10% of the acceptable limit. The method was fully validated, and proved sufficient in terms of selectivity, sensitivity, linearity, precision and accuracy. The factors involved in the method development and pathways for fragment ions of the four PMIs were also discussed and the study will contribute to risk management of PMIs present in ripretinib. The Royal Society of Chemistry 2022-09-08 /pmc/articles/PMC9455223/ /pubmed/36199346 http://dx.doi.org/10.1039/d2ra04505b Text en This journal is © The Royal Society of Chemistry https://creativecommons.org/licenses/by-nc/3.0/
spellingShingle Chemistry
Huang, Yiwen
Xu, Qi
Lu, Hui
Li, Zhong
Wu, Yang
A rapid and sensitive UPLC-MS/MS method for simultaneous determination of four potential mutagenic impurities at trace levels in ripretinib drug substance
title A rapid and sensitive UPLC-MS/MS method for simultaneous determination of four potential mutagenic impurities at trace levels in ripretinib drug substance
title_full A rapid and sensitive UPLC-MS/MS method for simultaneous determination of four potential mutagenic impurities at trace levels in ripretinib drug substance
title_fullStr A rapid and sensitive UPLC-MS/MS method for simultaneous determination of four potential mutagenic impurities at trace levels in ripretinib drug substance
title_full_unstemmed A rapid and sensitive UPLC-MS/MS method for simultaneous determination of four potential mutagenic impurities at trace levels in ripretinib drug substance
title_short A rapid and sensitive UPLC-MS/MS method for simultaneous determination of four potential mutagenic impurities at trace levels in ripretinib drug substance
title_sort rapid and sensitive uplc-ms/ms method for simultaneous determination of four potential mutagenic impurities at trace levels in ripretinib drug substance
topic Chemistry
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9455223/
https://www.ncbi.nlm.nih.gov/pubmed/36199346
http://dx.doi.org/10.1039/d2ra04505b
work_keys_str_mv AT huangyiwen arapidandsensitiveuplcmsmsmethodforsimultaneousdeterminationoffourpotentialmutagenicimpuritiesattracelevelsinripretinibdrugsubstance
AT xuqi arapidandsensitiveuplcmsmsmethodforsimultaneousdeterminationoffourpotentialmutagenicimpuritiesattracelevelsinripretinibdrugsubstance
AT luhui arapidandsensitiveuplcmsmsmethodforsimultaneousdeterminationoffourpotentialmutagenicimpuritiesattracelevelsinripretinibdrugsubstance
AT lizhong arapidandsensitiveuplcmsmsmethodforsimultaneousdeterminationoffourpotentialmutagenicimpuritiesattracelevelsinripretinibdrugsubstance
AT wuyang arapidandsensitiveuplcmsmsmethodforsimultaneousdeterminationoffourpotentialmutagenicimpuritiesattracelevelsinripretinibdrugsubstance
AT huangyiwen rapidandsensitiveuplcmsmsmethodforsimultaneousdeterminationoffourpotentialmutagenicimpuritiesattracelevelsinripretinibdrugsubstance
AT xuqi rapidandsensitiveuplcmsmsmethodforsimultaneousdeterminationoffourpotentialmutagenicimpuritiesattracelevelsinripretinibdrugsubstance
AT luhui rapidandsensitiveuplcmsmsmethodforsimultaneousdeterminationoffourpotentialmutagenicimpuritiesattracelevelsinripretinibdrugsubstance
AT lizhong rapidandsensitiveuplcmsmsmethodforsimultaneousdeterminationoffourpotentialmutagenicimpuritiesattracelevelsinripretinibdrugsubstance
AT wuyang rapidandsensitiveuplcmsmsmethodforsimultaneousdeterminationoffourpotentialmutagenicimpuritiesattracelevelsinripretinibdrugsubstance