Effect of Multi-Component on Crack Resistance of High-Performance Concrete on Subway Underground Station Floor
In view of the easy cracking of the high-performance concrete (HPC) of the subway underground station floor, the effects of fly ash, basalt fiber, expansive agent, and water reducer on the compressive strength, initial crack time, through-crack time, and crack area of the HPC on a subway underground...
Autores principales: | Xu, Shaoyun, Gao, Peiwei, Huang, Lingling, Chen, Lifeng, Cen, Feng, Zhao, Zhiqing, Tian, Yilang |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
MDPI
2022
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9457437/ https://www.ncbi.nlm.nih.gov/pubmed/36079249 http://dx.doi.org/10.3390/ma15175868 |