Cargando…
Morphometric Assessment for Functional Evaluation of Coronary Stenosis with Optical Coherence Tomography and the Optical Flow Ratio in a Vessel with Single Stenosis
Objectives: The study aimed to evaluate the diagnostic performance of optical coherence tomography (OCT) in identifying functionally significant coronary stenosis in a vessel with single stenosis. Background: The OCT-based morphofunctional computational method for deriving the optical flow ratio (OF...
Autores principales: | , , , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
MDPI
2022
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9457468/ https://www.ncbi.nlm.nih.gov/pubmed/36079128 http://dx.doi.org/10.3390/jcm11175198 |
_version_ | 1784786062668726272 |
---|---|
author | Huang, Yuming Lin, Zehuo Wu, Quanmin Chen, Liansheng Yang, Junqing Deng, Huiliang Liu, Yuanhui Xie, Nianjin |
author_facet | Huang, Yuming Lin, Zehuo Wu, Quanmin Chen, Liansheng Yang, Junqing Deng, Huiliang Liu, Yuanhui Xie, Nianjin |
author_sort | Huang, Yuming |
collection | PubMed |
description | Objectives: The study aimed to evaluate the diagnostic performance of optical coherence tomography (OCT) in identifying functionally significant coronary stenosis in a vessel with single stenosis. Background: The OCT-based morphofunctional computational method for deriving the optical flow ratio (OFR) has diagnostic value, as it can identify the functional severity of coronary stenosis, but the ability of the OFR to aid the OCT in determining coronary stenosis hemodynamics in single-stenosis lesion remains unclear. Methods: 74 vessels with single stenosis were studied in 69 patients; all cases were performed through OCT and quantitative flow ratio (QFR), and OCT images were used to perform OFR. Results: Among vessels with single stenosis, OFR showed a good correlation with QFR (r = 0.86; p < 0.001). Taking QFR as the standard, the vessel-level diagnosis accuracy, sensitivity, specificity, positive predictive value (PPV) and negative predictive value (NPV) of OFR were 90% (95% CI: 81 to 96), 94% (95% CI: 77 to 99), 88% (95% CI: 74 to 96), 85% (95% CI: 68 to 94) and 95% (95% CI: 82 to 99), respectively. Among vessels with OFR/QFR concordance, both the minimum lumen area (MLA) and minimum lumen diameter (MLD) showed excellent diagnostic efficiency (MLA: area under the curve (AUC) = 0.92, 95% CI: 0.85 to 0.98, p < 0.001; MLD: AUC = 0.93, 95% CI: 0.86 to 0.98, p < 0.001) in determining the functional significance of coronary stenosis in a single stenosis lesion, and the best cutoff values were 1.55 mm(2) and 1.40 mm. Conclusions: OFR has a good correlation with QFR. OCT-measured MLA and MLD have excellent diagnostic efficiency in identifying the hemodynamic significance of coronary stenosis in a vessel with single stenosis. |
format | Online Article Text |
id | pubmed-9457468 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2022 |
publisher | MDPI |
record_format | MEDLINE/PubMed |
spelling | pubmed-94574682022-09-09 Morphometric Assessment for Functional Evaluation of Coronary Stenosis with Optical Coherence Tomography and the Optical Flow Ratio in a Vessel with Single Stenosis Huang, Yuming Lin, Zehuo Wu, Quanmin Chen, Liansheng Yang, Junqing Deng, Huiliang Liu, Yuanhui Xie, Nianjin J Clin Med Article Objectives: The study aimed to evaluate the diagnostic performance of optical coherence tomography (OCT) in identifying functionally significant coronary stenosis in a vessel with single stenosis. Background: The OCT-based morphofunctional computational method for deriving the optical flow ratio (OFR) has diagnostic value, as it can identify the functional severity of coronary stenosis, but the ability of the OFR to aid the OCT in determining coronary stenosis hemodynamics in single-stenosis lesion remains unclear. Methods: 74 vessels with single stenosis were studied in 69 patients; all cases were performed through OCT and quantitative flow ratio (QFR), and OCT images were used to perform OFR. Results: Among vessels with single stenosis, OFR showed a good correlation with QFR (r = 0.86; p < 0.001). Taking QFR as the standard, the vessel-level diagnosis accuracy, sensitivity, specificity, positive predictive value (PPV) and negative predictive value (NPV) of OFR were 90% (95% CI: 81 to 96), 94% (95% CI: 77 to 99), 88% (95% CI: 74 to 96), 85% (95% CI: 68 to 94) and 95% (95% CI: 82 to 99), respectively. Among vessels with OFR/QFR concordance, both the minimum lumen area (MLA) and minimum lumen diameter (MLD) showed excellent diagnostic efficiency (MLA: area under the curve (AUC) = 0.92, 95% CI: 0.85 to 0.98, p < 0.001; MLD: AUC = 0.93, 95% CI: 0.86 to 0.98, p < 0.001) in determining the functional significance of coronary stenosis in a single stenosis lesion, and the best cutoff values were 1.55 mm(2) and 1.40 mm. Conclusions: OFR has a good correlation with QFR. OCT-measured MLA and MLD have excellent diagnostic efficiency in identifying the hemodynamic significance of coronary stenosis in a vessel with single stenosis. MDPI 2022-09-02 /pmc/articles/PMC9457468/ /pubmed/36079128 http://dx.doi.org/10.3390/jcm11175198 Text en © 2022 by the authors. https://creativecommons.org/licenses/by/4.0/Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license (https://creativecommons.org/licenses/by/4.0/). |
spellingShingle | Article Huang, Yuming Lin, Zehuo Wu, Quanmin Chen, Liansheng Yang, Junqing Deng, Huiliang Liu, Yuanhui Xie, Nianjin Morphometric Assessment for Functional Evaluation of Coronary Stenosis with Optical Coherence Tomography and the Optical Flow Ratio in a Vessel with Single Stenosis |
title | Morphometric Assessment for Functional Evaluation of Coronary Stenosis with Optical Coherence Tomography and the Optical Flow Ratio in a Vessel with Single Stenosis |
title_full | Morphometric Assessment for Functional Evaluation of Coronary Stenosis with Optical Coherence Tomography and the Optical Flow Ratio in a Vessel with Single Stenosis |
title_fullStr | Morphometric Assessment for Functional Evaluation of Coronary Stenosis with Optical Coherence Tomography and the Optical Flow Ratio in a Vessel with Single Stenosis |
title_full_unstemmed | Morphometric Assessment for Functional Evaluation of Coronary Stenosis with Optical Coherence Tomography and the Optical Flow Ratio in a Vessel with Single Stenosis |
title_short | Morphometric Assessment for Functional Evaluation of Coronary Stenosis with Optical Coherence Tomography and the Optical Flow Ratio in a Vessel with Single Stenosis |
title_sort | morphometric assessment for functional evaluation of coronary stenosis with optical coherence tomography and the optical flow ratio in a vessel with single stenosis |
topic | Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9457468/ https://www.ncbi.nlm.nih.gov/pubmed/36079128 http://dx.doi.org/10.3390/jcm11175198 |
work_keys_str_mv | AT huangyuming morphometricassessmentforfunctionalevaluationofcoronarystenosiswithopticalcoherencetomographyandtheopticalflowratioinavesselwithsinglestenosis AT linzehuo morphometricassessmentforfunctionalevaluationofcoronarystenosiswithopticalcoherencetomographyandtheopticalflowratioinavesselwithsinglestenosis AT wuquanmin morphometricassessmentforfunctionalevaluationofcoronarystenosiswithopticalcoherencetomographyandtheopticalflowratioinavesselwithsinglestenosis AT chenliansheng morphometricassessmentforfunctionalevaluationofcoronarystenosiswithopticalcoherencetomographyandtheopticalflowratioinavesselwithsinglestenosis AT yangjunqing morphometricassessmentforfunctionalevaluationofcoronarystenosiswithopticalcoherencetomographyandtheopticalflowratioinavesselwithsinglestenosis AT denghuiliang morphometricassessmentforfunctionalevaluationofcoronarystenosiswithopticalcoherencetomographyandtheopticalflowratioinavesselwithsinglestenosis AT liuyuanhui morphometricassessmentforfunctionalevaluationofcoronarystenosiswithopticalcoherencetomographyandtheopticalflowratioinavesselwithsinglestenosis AT xienianjin morphometricassessmentforfunctionalevaluationofcoronarystenosiswithopticalcoherencetomographyandtheopticalflowratioinavesselwithsinglestenosis |