Cargando…

Morphometric Assessment for Functional Evaluation of Coronary Stenosis with Optical Coherence Tomography and the Optical Flow Ratio in a Vessel with Single Stenosis

Objectives: The study aimed to evaluate the diagnostic performance of optical coherence tomography (OCT) in identifying functionally significant coronary stenosis in a vessel with single stenosis. Background: The OCT-based morphofunctional computational method for deriving the optical flow ratio (OF...

Descripción completa

Detalles Bibliográficos
Autores principales: Huang, Yuming, Lin, Zehuo, Wu, Quanmin, Chen, Liansheng, Yang, Junqing, Deng, Huiliang, Liu, Yuanhui, Xie, Nianjin
Formato: Online Artículo Texto
Lenguaje:English
Publicado: MDPI 2022
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9457468/
https://www.ncbi.nlm.nih.gov/pubmed/36079128
http://dx.doi.org/10.3390/jcm11175198
_version_ 1784786062668726272
author Huang, Yuming
Lin, Zehuo
Wu, Quanmin
Chen, Liansheng
Yang, Junqing
Deng, Huiliang
Liu, Yuanhui
Xie, Nianjin
author_facet Huang, Yuming
Lin, Zehuo
Wu, Quanmin
Chen, Liansheng
Yang, Junqing
Deng, Huiliang
Liu, Yuanhui
Xie, Nianjin
author_sort Huang, Yuming
collection PubMed
description Objectives: The study aimed to evaluate the diagnostic performance of optical coherence tomography (OCT) in identifying functionally significant coronary stenosis in a vessel with single stenosis. Background: The OCT-based morphofunctional computational method for deriving the optical flow ratio (OFR) has diagnostic value, as it can identify the functional severity of coronary stenosis, but the ability of the OFR to aid the OCT in determining coronary stenosis hemodynamics in single-stenosis lesion remains unclear. Methods: 74 vessels with single stenosis were studied in 69 patients; all cases were performed through OCT and quantitative flow ratio (QFR), and OCT images were used to perform OFR. Results: Among vessels with single stenosis, OFR showed a good correlation with QFR (r = 0.86; p < 0.001). Taking QFR as the standard, the vessel-level diagnosis accuracy, sensitivity, specificity, positive predictive value (PPV) and negative predictive value (NPV) of OFR were 90% (95% CI: 81 to 96), 94% (95% CI: 77 to 99), 88% (95% CI: 74 to 96), 85% (95% CI: 68 to 94) and 95% (95% CI: 82 to 99), respectively. Among vessels with OFR/QFR concordance, both the minimum lumen area (MLA) and minimum lumen diameter (MLD) showed excellent diagnostic efficiency (MLA: area under the curve (AUC) = 0.92, 95% CI: 0.85 to 0.98, p < 0.001; MLD: AUC = 0.93, 95% CI: 0.86 to 0.98, p < 0.001) in determining the functional significance of coronary stenosis in a single stenosis lesion, and the best cutoff values were 1.55 mm(2) and 1.40 mm. Conclusions: OFR has a good correlation with QFR. OCT-measured MLA and MLD have excellent diagnostic efficiency in identifying the hemodynamic significance of coronary stenosis in a vessel with single stenosis.
format Online
Article
Text
id pubmed-9457468
institution National Center for Biotechnology Information
language English
publishDate 2022
publisher MDPI
record_format MEDLINE/PubMed
spelling pubmed-94574682022-09-09 Morphometric Assessment for Functional Evaluation of Coronary Stenosis with Optical Coherence Tomography and the Optical Flow Ratio in a Vessel with Single Stenosis Huang, Yuming Lin, Zehuo Wu, Quanmin Chen, Liansheng Yang, Junqing Deng, Huiliang Liu, Yuanhui Xie, Nianjin J Clin Med Article Objectives: The study aimed to evaluate the diagnostic performance of optical coherence tomography (OCT) in identifying functionally significant coronary stenosis in a vessel with single stenosis. Background: The OCT-based morphofunctional computational method for deriving the optical flow ratio (OFR) has diagnostic value, as it can identify the functional severity of coronary stenosis, but the ability of the OFR to aid the OCT in determining coronary stenosis hemodynamics in single-stenosis lesion remains unclear. Methods: 74 vessels with single stenosis were studied in 69 patients; all cases were performed through OCT and quantitative flow ratio (QFR), and OCT images were used to perform OFR. Results: Among vessels with single stenosis, OFR showed a good correlation with QFR (r = 0.86; p < 0.001). Taking QFR as the standard, the vessel-level diagnosis accuracy, sensitivity, specificity, positive predictive value (PPV) and negative predictive value (NPV) of OFR were 90% (95% CI: 81 to 96), 94% (95% CI: 77 to 99), 88% (95% CI: 74 to 96), 85% (95% CI: 68 to 94) and 95% (95% CI: 82 to 99), respectively. Among vessels with OFR/QFR concordance, both the minimum lumen area (MLA) and minimum lumen diameter (MLD) showed excellent diagnostic efficiency (MLA: area under the curve (AUC) = 0.92, 95% CI: 0.85 to 0.98, p < 0.001; MLD: AUC = 0.93, 95% CI: 0.86 to 0.98, p < 0.001) in determining the functional significance of coronary stenosis in a single stenosis lesion, and the best cutoff values were 1.55 mm(2) and 1.40 mm. Conclusions: OFR has a good correlation with QFR. OCT-measured MLA and MLD have excellent diagnostic efficiency in identifying the hemodynamic significance of coronary stenosis in a vessel with single stenosis. MDPI 2022-09-02 /pmc/articles/PMC9457468/ /pubmed/36079128 http://dx.doi.org/10.3390/jcm11175198 Text en © 2022 by the authors. https://creativecommons.org/licenses/by/4.0/Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license (https://creativecommons.org/licenses/by/4.0/).
spellingShingle Article
Huang, Yuming
Lin, Zehuo
Wu, Quanmin
Chen, Liansheng
Yang, Junqing
Deng, Huiliang
Liu, Yuanhui
Xie, Nianjin
Morphometric Assessment for Functional Evaluation of Coronary Stenosis with Optical Coherence Tomography and the Optical Flow Ratio in a Vessel with Single Stenosis
title Morphometric Assessment for Functional Evaluation of Coronary Stenosis with Optical Coherence Tomography and the Optical Flow Ratio in a Vessel with Single Stenosis
title_full Morphometric Assessment for Functional Evaluation of Coronary Stenosis with Optical Coherence Tomography and the Optical Flow Ratio in a Vessel with Single Stenosis
title_fullStr Morphometric Assessment for Functional Evaluation of Coronary Stenosis with Optical Coherence Tomography and the Optical Flow Ratio in a Vessel with Single Stenosis
title_full_unstemmed Morphometric Assessment for Functional Evaluation of Coronary Stenosis with Optical Coherence Tomography and the Optical Flow Ratio in a Vessel with Single Stenosis
title_short Morphometric Assessment for Functional Evaluation of Coronary Stenosis with Optical Coherence Tomography and the Optical Flow Ratio in a Vessel with Single Stenosis
title_sort morphometric assessment for functional evaluation of coronary stenosis with optical coherence tomography and the optical flow ratio in a vessel with single stenosis
topic Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9457468/
https://www.ncbi.nlm.nih.gov/pubmed/36079128
http://dx.doi.org/10.3390/jcm11175198
work_keys_str_mv AT huangyuming morphometricassessmentforfunctionalevaluationofcoronarystenosiswithopticalcoherencetomographyandtheopticalflowratioinavesselwithsinglestenosis
AT linzehuo morphometricassessmentforfunctionalevaluationofcoronarystenosiswithopticalcoherencetomographyandtheopticalflowratioinavesselwithsinglestenosis
AT wuquanmin morphometricassessmentforfunctionalevaluationofcoronarystenosiswithopticalcoherencetomographyandtheopticalflowratioinavesselwithsinglestenosis
AT chenliansheng morphometricassessmentforfunctionalevaluationofcoronarystenosiswithopticalcoherencetomographyandtheopticalflowratioinavesselwithsinglestenosis
AT yangjunqing morphometricassessmentforfunctionalevaluationofcoronarystenosiswithopticalcoherencetomographyandtheopticalflowratioinavesselwithsinglestenosis
AT denghuiliang morphometricassessmentforfunctionalevaluationofcoronarystenosiswithopticalcoherencetomographyandtheopticalflowratioinavesselwithsinglestenosis
AT liuyuanhui morphometricassessmentforfunctionalevaluationofcoronarystenosiswithopticalcoherencetomographyandtheopticalflowratioinavesselwithsinglestenosis
AT xienianjin morphometricassessmentforfunctionalevaluationofcoronarystenosiswithopticalcoherencetomographyandtheopticalflowratioinavesselwithsinglestenosis