Cargando…
The association between plate location and hardware removal following ulna shortening osteotomy: a cohort study
Hardware removal after ulna shortening osteotomy is common. We evaluated the association between plate location and hardware removal rate in 326 procedures in 321 patients with a median follow-up of 4.3 years (IQR 3.3) and corrected for confounding variables and did survival analyses. Complications...
Autores principales: | , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
SAGE Publications
2022
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9459407/ https://www.ncbi.nlm.nih.gov/pubmed/35410539 http://dx.doi.org/10.1177/17531934221089228 |
_version_ | 1784786502253805568 |
---|---|
author | Teunissen, Joris S. Al Shaer, Sanharib van der Heijden, Brigitte P.A. Selles, Ruud W. Hovius, Steven E.R. Zöphel, Oliver T. |
author_facet | Teunissen, Joris S. Al Shaer, Sanharib van der Heijden, Brigitte P.A. Selles, Ruud W. Hovius, Steven E.R. Zöphel, Oliver T. |
author_sort | Teunissen, Joris S. |
collection | PubMed |
description | Hardware removal after ulna shortening osteotomy is common. We evaluated the association between plate location and hardware removal rate in 326 procedures in 321 patients with a median follow-up of 4.3 years (IQR 3.3) and corrected for confounding variables and did survival analyses. Complications were scored using the International Consortium for Health Outcome Measurement complications in Hand and Wrist Conditions tool. The 1-year and 5-year reoperation rates for hardware removal were 21% and 46% in the anterior group versus 37% and 64% in the dorsal group. Anterior plate placement was independently associated with a decreased immediate risk of hardware removal. Higher age, male sex and treatment on the dominant side were also associated with a reduced risk of hardware removal. We did not find a difference in hardware removal rates between freehand or jig-guided ulna shortening osteotomies. We noted perioperative problems in 3% of the procedures and complications in 20%. Level of evidence: III |
format | Online Article Text |
id | pubmed-9459407 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2022 |
publisher | SAGE Publications |
record_format | MEDLINE/PubMed |
spelling | pubmed-94594072022-09-10 The association between plate location and hardware removal following ulna shortening osteotomy: a cohort study Teunissen, Joris S. Al Shaer, Sanharib van der Heijden, Brigitte P.A. Selles, Ruud W. Hovius, Steven E.R. Zöphel, Oliver T. J Hand Surg Eur Vol Full Length Article Hardware removal after ulna shortening osteotomy is common. We evaluated the association between plate location and hardware removal rate in 326 procedures in 321 patients with a median follow-up of 4.3 years (IQR 3.3) and corrected for confounding variables and did survival analyses. Complications were scored using the International Consortium for Health Outcome Measurement complications in Hand and Wrist Conditions tool. The 1-year and 5-year reoperation rates for hardware removal were 21% and 46% in the anterior group versus 37% and 64% in the dorsal group. Anterior plate placement was independently associated with a decreased immediate risk of hardware removal. Higher age, male sex and treatment on the dominant side were also associated with a reduced risk of hardware removal. We did not find a difference in hardware removal rates between freehand or jig-guided ulna shortening osteotomies. We noted perioperative problems in 3% of the procedures and complications in 20%. Level of evidence: III SAGE Publications 2022-04-11 2022-09 /pmc/articles/PMC9459407/ /pubmed/35410539 http://dx.doi.org/10.1177/17531934221089228 Text en © The Author(s) 2022 https://creativecommons.org/licenses/by/4.0/This article is distributed under the terms of the Creative Commons Attribution 4.0 License (https://creativecommons.org/licenses/by/4.0/) which permits any use, reproduction and distribution of the work without further permission provided the original work is attributed as specified on the SAGE and Open Access pages (https://us.sagepub.com/en-us/nam/open-access-at-sage). |
spellingShingle | Full Length Article Teunissen, Joris S. Al Shaer, Sanharib van der Heijden, Brigitte P.A. Selles, Ruud W. Hovius, Steven E.R. Zöphel, Oliver T. The association between plate location and hardware removal following ulna shortening osteotomy: a cohort study |
title | The association between plate location and hardware removal following ulna
shortening osteotomy: a cohort study |
title_full | The association between plate location and hardware removal following ulna
shortening osteotomy: a cohort study |
title_fullStr | The association between plate location and hardware removal following ulna
shortening osteotomy: a cohort study |
title_full_unstemmed | The association between plate location and hardware removal following ulna
shortening osteotomy: a cohort study |
title_short | The association between plate location and hardware removal following ulna
shortening osteotomy: a cohort study |
title_sort | association between plate location and hardware removal following ulna
shortening osteotomy: a cohort study |
topic | Full Length Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9459407/ https://www.ncbi.nlm.nih.gov/pubmed/35410539 http://dx.doi.org/10.1177/17531934221089228 |
work_keys_str_mv | AT teunissenjoriss theassociationbetweenplatelocationandhardwareremovalfollowingulnashorteningosteotomyacohortstudy AT alshaersanharib theassociationbetweenplatelocationandhardwareremovalfollowingulnashorteningosteotomyacohortstudy AT vanderheijdenbrigittepa theassociationbetweenplatelocationandhardwareremovalfollowingulnashorteningosteotomyacohortstudy AT sellesruudw theassociationbetweenplatelocationandhardwareremovalfollowingulnashorteningosteotomyacohortstudy AT hoviusstevener theassociationbetweenplatelocationandhardwareremovalfollowingulnashorteningosteotomyacohortstudy AT zophelolivert theassociationbetweenplatelocationandhardwareremovalfollowingulnashorteningosteotomyacohortstudy AT theassociationbetweenplatelocationandhardwareremovalfollowingulnashorteningosteotomyacohortstudy AT teunissenjoriss associationbetweenplatelocationandhardwareremovalfollowingulnashorteningosteotomyacohortstudy AT alshaersanharib associationbetweenplatelocationandhardwareremovalfollowingulnashorteningosteotomyacohortstudy AT vanderheijdenbrigittepa associationbetweenplatelocationandhardwareremovalfollowingulnashorteningosteotomyacohortstudy AT sellesruudw associationbetweenplatelocationandhardwareremovalfollowingulnashorteningosteotomyacohortstudy AT hoviusstevener associationbetweenplatelocationandhardwareremovalfollowingulnashorteningosteotomyacohortstudy AT zophelolivert associationbetweenplatelocationandhardwareremovalfollowingulnashorteningosteotomyacohortstudy AT associationbetweenplatelocationandhardwareremovalfollowingulnashorteningosteotomyacohortstudy |