The association between plate location and hardware removal following ulna shortening osteotomy: a cohort study

Hardware removal after ulna shortening osteotomy is common. We evaluated the association between plate location and hardware removal rate in 326 procedures in 321 patients with a median follow-up of 4.3 years (IQR 3.3) and corrected for confounding variables and did survival analyses. Complications...

Descripción completa

Detalles Bibliográficos
Autores principales: Teunissen, Joris S., Al Shaer, Sanharib, van der Heijden, Brigitte P.A., Selles, Ruud W., Hovius, Steven E.R., Zöphel, Oliver T.
Formato: Online Artículo Texto
Lenguaje:English
Publicado: SAGE Publications 2022
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9459407/
https://www.ncbi.nlm.nih.gov/pubmed/35410539
http://dx.doi.org/10.1177/17531934221089228
_version_ 1784786502253805568
author Teunissen, Joris S.
Al Shaer, Sanharib
van der Heijden, Brigitte P.A.
Selles, Ruud W.
Hovius, Steven E.R.
Zöphel, Oliver T.
author_facet Teunissen, Joris S.
Al Shaer, Sanharib
van der Heijden, Brigitte P.A.
Selles, Ruud W.
Hovius, Steven E.R.
Zöphel, Oliver T.
author_sort Teunissen, Joris S.
collection PubMed
description Hardware removal after ulna shortening osteotomy is common. We evaluated the association between plate location and hardware removal rate in 326 procedures in 321 patients with a median follow-up of 4.3 years (IQR 3.3) and corrected for confounding variables and did survival analyses. Complications were scored using the International Consortium for Health Outcome Measurement complications in Hand and Wrist Conditions tool. The 1-year and 5-year reoperation rates for hardware removal were 21% and 46% in the anterior group versus 37% and 64% in the dorsal group. Anterior plate placement was independently associated with a decreased immediate risk of hardware removal. Higher age, male sex and treatment on the dominant side were also associated with a reduced risk of hardware removal. We did not find a difference in hardware removal rates between freehand or jig-guided ulna shortening osteotomies. We noted perioperative problems in 3% of the procedures and complications in 20%. Level of evidence: III
format Online
Article
Text
id pubmed-9459407
institution National Center for Biotechnology Information
language English
publishDate 2022
publisher SAGE Publications
record_format MEDLINE/PubMed
spelling pubmed-94594072022-09-10 The association between plate location and hardware removal following ulna shortening osteotomy: a cohort study Teunissen, Joris S. Al Shaer, Sanharib van der Heijden, Brigitte P.A. Selles, Ruud W. Hovius, Steven E.R. Zöphel, Oliver T. J Hand Surg Eur Vol Full Length Article Hardware removal after ulna shortening osteotomy is common. We evaluated the association between plate location and hardware removal rate in 326 procedures in 321 patients with a median follow-up of 4.3 years (IQR 3.3) and corrected for confounding variables and did survival analyses. Complications were scored using the International Consortium for Health Outcome Measurement complications in Hand and Wrist Conditions tool. The 1-year and 5-year reoperation rates for hardware removal were 21% and 46% in the anterior group versus 37% and 64% in the dorsal group. Anterior plate placement was independently associated with a decreased immediate risk of hardware removal. Higher age, male sex and treatment on the dominant side were also associated with a reduced risk of hardware removal. We did not find a difference in hardware removal rates between freehand or jig-guided ulna shortening osteotomies. We noted perioperative problems in 3% of the procedures and complications in 20%. Level of evidence: III SAGE Publications 2022-04-11 2022-09 /pmc/articles/PMC9459407/ /pubmed/35410539 http://dx.doi.org/10.1177/17531934221089228 Text en © The Author(s) 2022 https://creativecommons.org/licenses/by/4.0/This article is distributed under the terms of the Creative Commons Attribution 4.0 License (https://creativecommons.org/licenses/by/4.0/) which permits any use, reproduction and distribution of the work without further permission provided the original work is attributed as specified on the SAGE and Open Access pages (https://us.sagepub.com/en-us/nam/open-access-at-sage).
spellingShingle Full Length Article
Teunissen, Joris S.
Al Shaer, Sanharib
van der Heijden, Brigitte P.A.
Selles, Ruud W.
Hovius, Steven E.R.
Zöphel, Oliver T.
The association between plate location and hardware removal following ulna shortening osteotomy: a cohort study
title The association between plate location and hardware removal following ulna shortening osteotomy: a cohort study
title_full The association between plate location and hardware removal following ulna shortening osteotomy: a cohort study
title_fullStr The association between plate location and hardware removal following ulna shortening osteotomy: a cohort study
title_full_unstemmed The association between plate location and hardware removal following ulna shortening osteotomy: a cohort study
title_short The association between plate location and hardware removal following ulna shortening osteotomy: a cohort study
title_sort association between plate location and hardware removal following ulna shortening osteotomy: a cohort study
topic Full Length Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9459407/
https://www.ncbi.nlm.nih.gov/pubmed/35410539
http://dx.doi.org/10.1177/17531934221089228
work_keys_str_mv AT teunissenjoriss theassociationbetweenplatelocationandhardwareremovalfollowingulnashorteningosteotomyacohortstudy
AT alshaersanharib theassociationbetweenplatelocationandhardwareremovalfollowingulnashorteningosteotomyacohortstudy
AT vanderheijdenbrigittepa theassociationbetweenplatelocationandhardwareremovalfollowingulnashorteningosteotomyacohortstudy
AT sellesruudw theassociationbetweenplatelocationandhardwareremovalfollowingulnashorteningosteotomyacohortstudy
AT hoviusstevener theassociationbetweenplatelocationandhardwareremovalfollowingulnashorteningosteotomyacohortstudy
AT zophelolivert theassociationbetweenplatelocationandhardwareremovalfollowingulnashorteningosteotomyacohortstudy
AT theassociationbetweenplatelocationandhardwareremovalfollowingulnashorteningosteotomyacohortstudy
AT teunissenjoriss associationbetweenplatelocationandhardwareremovalfollowingulnashorteningosteotomyacohortstudy
AT alshaersanharib associationbetweenplatelocationandhardwareremovalfollowingulnashorteningosteotomyacohortstudy
AT vanderheijdenbrigittepa associationbetweenplatelocationandhardwareremovalfollowingulnashorteningosteotomyacohortstudy
AT sellesruudw associationbetweenplatelocationandhardwareremovalfollowingulnashorteningosteotomyacohortstudy
AT hoviusstevener associationbetweenplatelocationandhardwareremovalfollowingulnashorteningosteotomyacohortstudy
AT zophelolivert associationbetweenplatelocationandhardwareremovalfollowingulnashorteningosteotomyacohortstudy
AT associationbetweenplatelocationandhardwareremovalfollowingulnashorteningosteotomyacohortstudy