Cargando…

Surgical Repair of the Extrusion of the Body of a PAUL Implant for Glaucoma

The purpose of our article was to describe a simple but effective surgical technique performed on a patient with an extrusion of part of the body of a PAUL drainage implant for glaucoma. We present the case of a patient with refractory glaucoma and a history of multiple ocular interventions. A PAUL...

Descripción completa

Detalles Bibliográficos
Autores principales: Milla, Elena, Izquierdo, Jordi, Sanchez Dalmau, Bernardo
Formato: Online Artículo Texto
Lenguaje:English
Publicado: S. Karger AG 2022
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9459591/
https://www.ncbi.nlm.nih.gov/pubmed/36160493
http://dx.doi.org/10.1159/000525985
_version_ 1784786547640369152
author Milla, Elena
Izquierdo, Jordi
Sanchez Dalmau, Bernardo
author_facet Milla, Elena
Izquierdo, Jordi
Sanchez Dalmau, Bernardo
author_sort Milla, Elena
collection PubMed
description The purpose of our article was to describe a simple but effective surgical technique performed on a patient with an extrusion of part of the body of a PAUL drainage implant for glaucoma. We present the case of a patient with refractory glaucoma and a history of multiple ocular interventions. A PAUL shunt was implanted and in the early postoperative period the patient presented extrusion of part of the implant body. An excessive scarring tissue at the lateral rectus muscle tendon hampered the placement of the lateral wing under the muscle; therefore, we decided to trim a part of it and suture the implant body to the sclera. The surgical technique that satisfactorily resolved the complication is described and shown in a video. This is the first time that such complication is described with the PAUL implant. We suggest that the intrinsic characteristics of the implant, mainly the dimensions, material, and thickness, made it possible for a potentially serious complication such as that described to be solved in a relatively simple and nontraumatic way for the eye.
format Online
Article
Text
id pubmed-9459591
institution National Center for Biotechnology Information
language English
publishDate 2022
publisher S. Karger AG
record_format MEDLINE/PubMed
spelling pubmed-94595912022-09-23 Surgical Repair of the Extrusion of the Body of a PAUL Implant for Glaucoma Milla, Elena Izquierdo, Jordi Sanchez Dalmau, Bernardo Case Rep Ophthalmol Case Report The purpose of our article was to describe a simple but effective surgical technique performed on a patient with an extrusion of part of the body of a PAUL drainage implant for glaucoma. We present the case of a patient with refractory glaucoma and a history of multiple ocular interventions. A PAUL shunt was implanted and in the early postoperative period the patient presented extrusion of part of the implant body. An excessive scarring tissue at the lateral rectus muscle tendon hampered the placement of the lateral wing under the muscle; therefore, we decided to trim a part of it and suture the implant body to the sclera. The surgical technique that satisfactorily resolved the complication is described and shown in a video. This is the first time that such complication is described with the PAUL implant. We suggest that the intrinsic characteristics of the implant, mainly the dimensions, material, and thickness, made it possible for a potentially serious complication such as that described to be solved in a relatively simple and nontraumatic way for the eye. S. Karger AG 2022-08-31 /pmc/articles/PMC9459591/ /pubmed/36160493 http://dx.doi.org/10.1159/000525985 Text en Copyright © 2022 by The Author(s). Published by S. Karger AG, Basel https://creativecommons.org/licenses/by-nc/4.0/This article is licensed under the Creative Commons Attribution-NonCommercial-4.0 International License (CC BY-NC) (http://www.karger.com/Services/OpenAccessLicense). Usage and distribution for commercial purposes requires written permission.
spellingShingle Case Report
Milla, Elena
Izquierdo, Jordi
Sanchez Dalmau, Bernardo
Surgical Repair of the Extrusion of the Body of a PAUL Implant for Glaucoma
title Surgical Repair of the Extrusion of the Body of a PAUL Implant for Glaucoma
title_full Surgical Repair of the Extrusion of the Body of a PAUL Implant for Glaucoma
title_fullStr Surgical Repair of the Extrusion of the Body of a PAUL Implant for Glaucoma
title_full_unstemmed Surgical Repair of the Extrusion of the Body of a PAUL Implant for Glaucoma
title_short Surgical Repair of the Extrusion of the Body of a PAUL Implant for Glaucoma
title_sort surgical repair of the extrusion of the body of a paul implant for glaucoma
topic Case Report
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9459591/
https://www.ncbi.nlm.nih.gov/pubmed/36160493
http://dx.doi.org/10.1159/000525985
work_keys_str_mv AT millaelena surgicalrepairoftheextrusionofthebodyofapaulimplantforglaucoma
AT izquierdojordi surgicalrepairoftheextrusionofthebodyofapaulimplantforglaucoma
AT sanchezdalmaubernardo surgicalrepairoftheextrusionofthebodyofapaulimplantforglaucoma