Cargando…
Comparison of operation time, efficacy and safety between through-the-scope stent and over-the-while stent in malignant central airway obstruction: a multi-center randomized control trial
BACKGROUND: Self-expandable metallic (SEM) airway stents are an important approach to treating malignant central airway obstruction (CAO). Standard over-the-while (OTW) stent needs the guidance of a guide-wire. It should be implanted under flouroscopy or the guidance of bronchoscope visualization. I...
Autores principales: | , , , , , , , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
AME Publishing Company
2022
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9459625/ https://www.ncbi.nlm.nih.gov/pubmed/36090647 http://dx.doi.org/10.21037/tlcr-22-565 |
_version_ | 1784786556071968768 |
---|---|
author | Zeng, Da-Xiong Cheng, Zhao-Zhong Lv, Xue-Dong Chen, Cheng-Shui Wang, Ji-Wang Browning, Robert Wang, Ko-Pen Huang, Jian-An Dutau, Hervé Kheir, Fayez Ke, Ming-Yao Jiang, Jun-Hong |
author_facet | Zeng, Da-Xiong Cheng, Zhao-Zhong Lv, Xue-Dong Chen, Cheng-Shui Wang, Ji-Wang Browning, Robert Wang, Ko-Pen Huang, Jian-An Dutau, Hervé Kheir, Fayez Ke, Ming-Yao Jiang, Jun-Hong |
author_sort | Zeng, Da-Xiong |
collection | PubMed |
description | BACKGROUND: Self-expandable metallic (SEM) airway stents are an important approach to treating malignant central airway obstruction (CAO). Standard over-the-while (OTW) stent needs the guidance of a guide-wire. It should be implanted under flouroscopy or the guidance of bronchoscope visualization. In this study, we evaluated the operation time and safety between OTW stent and a novel through-the-scope (TTS) SEM airway stent. METHODS: In this multi-center, randomized, parallel-group superiority study, malignant CAO patients were enrolled randomly assigned (2:1) to the TTS stent implantation group (TTS group) or the standard OTW stent group (OTW group) in six sites across China. The entire process of all surgical procedures was recorded by video. Primary endpoint was the operation time of the airway stent implantation and secondary endpoint was the success rate of the stent implantation as well as its efficacy and safety. RESULTS: From May 15, 2017, to December 30, 2018, 148 patients were enrolled from the six sites. We analyzed 134 patients (including 91 patients from the TTS group and 43 patients from the OTW group) according to the per-protocol set. There were no significant differences in the ages, genders, underlying diseases, and stenosis sites between the two groups. The operation time in the TTS group was significantly shorter than that in the OTW group (104±68 vs. 252±111 seconds, P<0.001). Compared to the OTW group, the efficacy of stent implantation (97.80% vs. 90.70%, P=0.093) and rate of first-time successful stent implantation (78.02% vs. 74.42%, P=0.668) were higher in the TTS group, but did not reach statistically significance. The rates of granulation (28.57% vs. 41.86%, P=0.128) and restenosis (15.38% vs. 30.23%, P=0.064) in the TTS group were slightly lower as compared with the OTW group without achieving statistical significance. CONCLUSIONS: The TTS stent implantation procedure time was significantly shorter than that of the OTW airway stent with similar efficacy and complications, which might reduce the risk and flexibility of stent implantation. TRIAL REGISTRATION: Chinese Clinical Trial Registry ChiCTR-IOR-17011431. |
format | Online Article Text |
id | pubmed-9459625 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2022 |
publisher | AME Publishing Company |
record_format | MEDLINE/PubMed |
spelling | pubmed-94596252022-09-10 Comparison of operation time, efficacy and safety between through-the-scope stent and over-the-while stent in malignant central airway obstruction: a multi-center randomized control trial Zeng, Da-Xiong Cheng, Zhao-Zhong Lv, Xue-Dong Chen, Cheng-Shui Wang, Ji-Wang Browning, Robert Wang, Ko-Pen Huang, Jian-An Dutau, Hervé Kheir, Fayez Ke, Ming-Yao Jiang, Jun-Hong Transl Lung Cancer Res Original Article BACKGROUND: Self-expandable metallic (SEM) airway stents are an important approach to treating malignant central airway obstruction (CAO). Standard over-the-while (OTW) stent needs the guidance of a guide-wire. It should be implanted under flouroscopy or the guidance of bronchoscope visualization. In this study, we evaluated the operation time and safety between OTW stent and a novel through-the-scope (TTS) SEM airway stent. METHODS: In this multi-center, randomized, parallel-group superiority study, malignant CAO patients were enrolled randomly assigned (2:1) to the TTS stent implantation group (TTS group) or the standard OTW stent group (OTW group) in six sites across China. The entire process of all surgical procedures was recorded by video. Primary endpoint was the operation time of the airway stent implantation and secondary endpoint was the success rate of the stent implantation as well as its efficacy and safety. RESULTS: From May 15, 2017, to December 30, 2018, 148 patients were enrolled from the six sites. We analyzed 134 patients (including 91 patients from the TTS group and 43 patients from the OTW group) according to the per-protocol set. There were no significant differences in the ages, genders, underlying diseases, and stenosis sites between the two groups. The operation time in the TTS group was significantly shorter than that in the OTW group (104±68 vs. 252±111 seconds, P<0.001). Compared to the OTW group, the efficacy of stent implantation (97.80% vs. 90.70%, P=0.093) and rate of first-time successful stent implantation (78.02% vs. 74.42%, P=0.668) were higher in the TTS group, but did not reach statistically significance. The rates of granulation (28.57% vs. 41.86%, P=0.128) and restenosis (15.38% vs. 30.23%, P=0.064) in the TTS group were slightly lower as compared with the OTW group without achieving statistical significance. CONCLUSIONS: The TTS stent implantation procedure time was significantly shorter than that of the OTW airway stent with similar efficacy and complications, which might reduce the risk and flexibility of stent implantation. TRIAL REGISTRATION: Chinese Clinical Trial Registry ChiCTR-IOR-17011431. AME Publishing Company 2022-08 /pmc/articles/PMC9459625/ /pubmed/36090647 http://dx.doi.org/10.21037/tlcr-22-565 Text en 2022 Translational Lung Cancer Research. All rights reserved. https://creativecommons.org/licenses/by-nc-nd/4.0/Open Access Statement: This is an Open Access article distributed in accordance with the Creative Commons Attribution-NonCommercial-NoDerivs 4.0 International License (CC BY-NC-ND 4.0), which permits the non-commercial replication and distribution of the article with the strict proviso that no changes or edits are made and the original work is properly cited (including links to both the formal publication through the relevant DOI and the license). See: https://creativecommons.org/licenses/by-nc-nd/4.0 (https://creativecommons.org/licenses/by-nc-nd/4.0/) . |
spellingShingle | Original Article Zeng, Da-Xiong Cheng, Zhao-Zhong Lv, Xue-Dong Chen, Cheng-Shui Wang, Ji-Wang Browning, Robert Wang, Ko-Pen Huang, Jian-An Dutau, Hervé Kheir, Fayez Ke, Ming-Yao Jiang, Jun-Hong Comparison of operation time, efficacy and safety between through-the-scope stent and over-the-while stent in malignant central airway obstruction: a multi-center randomized control trial |
title | Comparison of operation time, efficacy and safety between through-the-scope stent and over-the-while stent in malignant central airway obstruction: a multi-center randomized control trial |
title_full | Comparison of operation time, efficacy and safety between through-the-scope stent and over-the-while stent in malignant central airway obstruction: a multi-center randomized control trial |
title_fullStr | Comparison of operation time, efficacy and safety between through-the-scope stent and over-the-while stent in malignant central airway obstruction: a multi-center randomized control trial |
title_full_unstemmed | Comparison of operation time, efficacy and safety between through-the-scope stent and over-the-while stent in malignant central airway obstruction: a multi-center randomized control trial |
title_short | Comparison of operation time, efficacy and safety between through-the-scope stent and over-the-while stent in malignant central airway obstruction: a multi-center randomized control trial |
title_sort | comparison of operation time, efficacy and safety between through-the-scope stent and over-the-while stent in malignant central airway obstruction: a multi-center randomized control trial |
topic | Original Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9459625/ https://www.ncbi.nlm.nih.gov/pubmed/36090647 http://dx.doi.org/10.21037/tlcr-22-565 |
work_keys_str_mv | AT zengdaxiong comparisonofoperationtimeefficacyandsafetybetweenthroughthescopestentandoverthewhilestentinmalignantcentralairwayobstructionamulticenterrandomizedcontroltrial AT chengzhaozhong comparisonofoperationtimeefficacyandsafetybetweenthroughthescopestentandoverthewhilestentinmalignantcentralairwayobstructionamulticenterrandomizedcontroltrial AT lvxuedong comparisonofoperationtimeefficacyandsafetybetweenthroughthescopestentandoverthewhilestentinmalignantcentralairwayobstructionamulticenterrandomizedcontroltrial AT chenchengshui comparisonofoperationtimeefficacyandsafetybetweenthroughthescopestentandoverthewhilestentinmalignantcentralairwayobstructionamulticenterrandomizedcontroltrial AT wangjiwang comparisonofoperationtimeefficacyandsafetybetweenthroughthescopestentandoverthewhilestentinmalignantcentralairwayobstructionamulticenterrandomizedcontroltrial AT browningrobert comparisonofoperationtimeefficacyandsafetybetweenthroughthescopestentandoverthewhilestentinmalignantcentralairwayobstructionamulticenterrandomizedcontroltrial AT wangkopen comparisonofoperationtimeefficacyandsafetybetweenthroughthescopestentandoverthewhilestentinmalignantcentralairwayobstructionamulticenterrandomizedcontroltrial AT huangjianan comparisonofoperationtimeefficacyandsafetybetweenthroughthescopestentandoverthewhilestentinmalignantcentralairwayobstructionamulticenterrandomizedcontroltrial AT dutauherve comparisonofoperationtimeefficacyandsafetybetweenthroughthescopestentandoverthewhilestentinmalignantcentralairwayobstructionamulticenterrandomizedcontroltrial AT kheirfayez comparisonofoperationtimeefficacyandsafetybetweenthroughthescopestentandoverthewhilestentinmalignantcentralairwayobstructionamulticenterrandomizedcontroltrial AT kemingyao comparisonofoperationtimeefficacyandsafetybetweenthroughthescopestentandoverthewhilestentinmalignantcentralairwayobstructionamulticenterrandomizedcontroltrial AT jiangjunhong comparisonofoperationtimeefficacyandsafetybetweenthroughthescopestentandoverthewhilestentinmalignantcentralairwayobstructionamulticenterrandomizedcontroltrial |