Cargando…

Extra-Oral Three-Dimensional (3D) Scanning Evaluation of Three Different Impression Materials—An In Vitro Study

Impression materials are used to record and reproduce the exact morphology of the patient’s oral cavity. The dimensional stability of a material is its ability to maintain the accuracy of recording the details of the oral cavity for a longer period of time, including the time during imprinting and i...

Descripción completa

Detalles Bibliográficos
Autores principales: Bud, Eugen S., Bocanet, Vlad I., Muntean, Mircea H., Vlasa, Alexandru, Păcurar, Mariana, Zetu, Irina Nicoleta, Soporan, Bianca I., Bud, Anamaria
Formato: Online Artículo Texto
Lenguaje:English
Publicado: MDPI 2022
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9459976/
https://www.ncbi.nlm.nih.gov/pubmed/36080753
http://dx.doi.org/10.3390/polym14173678
_version_ 1784786637460340736
author Bud, Eugen S.
Bocanet, Vlad I.
Muntean, Mircea H.
Vlasa, Alexandru
Păcurar, Mariana
Zetu, Irina Nicoleta
Soporan, Bianca I.
Bud, Anamaria
author_facet Bud, Eugen S.
Bocanet, Vlad I.
Muntean, Mircea H.
Vlasa, Alexandru
Păcurar, Mariana
Zetu, Irina Nicoleta
Soporan, Bianca I.
Bud, Anamaria
author_sort Bud, Eugen S.
collection PubMed
description Impression materials are used to record and reproduce the exact morphology of the patient’s oral cavity. The dimensional stability of a material is its ability to maintain the accuracy of recording the details of the oral cavity for a longer period of time, including the time during imprinting and immediately after. The aim of this study was to evaluate the accuracy of three different impression materials commonly used in the dental practice with the aid of an extra-oral three-dimensional (3D) scanner using an in vitro analysis. A typodont tooth model of the maxillary dental arch and mandibular dental arch, containing 16 permanent teeth, was used for evaluation. With the aid of three different impression materials, this model was imprinted fifteen times, resulting in fifteen different plaster models. A capsule extra-oral scanner device was used to digitalize the models and the same device was later used to align, compare, and measure scanned model surfaces. After performing the Kruskal–Wallis test for each measurement category (model), only two out of the fifteen measurements showed statistically significant differences between the material groups: vestibular-oral and mesial-distal width. Post hoc analysis showed that the alginate model (mean range = 29.13) had significantly higher bias scores than the addition silicone model (mean range = 16.75) (z = 2.501, p = 0.037). The difference between the average values of the model bias made from condensation-based silicone and addition-based silicone was initially significant, but after applying the Bonferroni correction for further comparisons, this relationship did not remain significant (z = 2.197, p = 0.084). Addition-based silicone models had the highest accuracy in terms of fidelity, followed by condensation-based silicones, and then by alginate models. Silicone-based impression materials improved over time, being highly used in all areas of dentistry. Alginate impressions had the lowest pattern of accuracy among those studied.
format Online
Article
Text
id pubmed-9459976
institution National Center for Biotechnology Information
language English
publishDate 2022
publisher MDPI
record_format MEDLINE/PubMed
spelling pubmed-94599762022-09-10 Extra-Oral Three-Dimensional (3D) Scanning Evaluation of Three Different Impression Materials—An In Vitro Study Bud, Eugen S. Bocanet, Vlad I. Muntean, Mircea H. Vlasa, Alexandru Păcurar, Mariana Zetu, Irina Nicoleta Soporan, Bianca I. Bud, Anamaria Polymers (Basel) Article Impression materials are used to record and reproduce the exact morphology of the patient’s oral cavity. The dimensional stability of a material is its ability to maintain the accuracy of recording the details of the oral cavity for a longer period of time, including the time during imprinting and immediately after. The aim of this study was to evaluate the accuracy of three different impression materials commonly used in the dental practice with the aid of an extra-oral three-dimensional (3D) scanner using an in vitro analysis. A typodont tooth model of the maxillary dental arch and mandibular dental arch, containing 16 permanent teeth, was used for evaluation. With the aid of three different impression materials, this model was imprinted fifteen times, resulting in fifteen different plaster models. A capsule extra-oral scanner device was used to digitalize the models and the same device was later used to align, compare, and measure scanned model surfaces. After performing the Kruskal–Wallis test for each measurement category (model), only two out of the fifteen measurements showed statistically significant differences between the material groups: vestibular-oral and mesial-distal width. Post hoc analysis showed that the alginate model (mean range = 29.13) had significantly higher bias scores than the addition silicone model (mean range = 16.75) (z = 2.501, p = 0.037). The difference between the average values of the model bias made from condensation-based silicone and addition-based silicone was initially significant, but after applying the Bonferroni correction for further comparisons, this relationship did not remain significant (z = 2.197, p = 0.084). Addition-based silicone models had the highest accuracy in terms of fidelity, followed by condensation-based silicones, and then by alginate models. Silicone-based impression materials improved over time, being highly used in all areas of dentistry. Alginate impressions had the lowest pattern of accuracy among those studied. MDPI 2022-09-05 /pmc/articles/PMC9459976/ /pubmed/36080753 http://dx.doi.org/10.3390/polym14173678 Text en © 2022 by the authors. https://creativecommons.org/licenses/by/4.0/Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license (https://creativecommons.org/licenses/by/4.0/).
spellingShingle Article
Bud, Eugen S.
Bocanet, Vlad I.
Muntean, Mircea H.
Vlasa, Alexandru
Păcurar, Mariana
Zetu, Irina Nicoleta
Soporan, Bianca I.
Bud, Anamaria
Extra-Oral Three-Dimensional (3D) Scanning Evaluation of Three Different Impression Materials—An In Vitro Study
title Extra-Oral Three-Dimensional (3D) Scanning Evaluation of Three Different Impression Materials—An In Vitro Study
title_full Extra-Oral Three-Dimensional (3D) Scanning Evaluation of Three Different Impression Materials—An In Vitro Study
title_fullStr Extra-Oral Three-Dimensional (3D) Scanning Evaluation of Three Different Impression Materials—An In Vitro Study
title_full_unstemmed Extra-Oral Three-Dimensional (3D) Scanning Evaluation of Three Different Impression Materials—An In Vitro Study
title_short Extra-Oral Three-Dimensional (3D) Scanning Evaluation of Three Different Impression Materials—An In Vitro Study
title_sort extra-oral three-dimensional (3d) scanning evaluation of three different impression materials—an in vitro study
topic Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9459976/
https://www.ncbi.nlm.nih.gov/pubmed/36080753
http://dx.doi.org/10.3390/polym14173678
work_keys_str_mv AT budeugens extraoralthreedimensional3dscanningevaluationofthreedifferentimpressionmaterialsaninvitrostudy
AT bocanetvladi extraoralthreedimensional3dscanningevaluationofthreedifferentimpressionmaterialsaninvitrostudy
AT munteanmirceah extraoralthreedimensional3dscanningevaluationofthreedifferentimpressionmaterialsaninvitrostudy
AT vlasaalexandru extraoralthreedimensional3dscanningevaluationofthreedifferentimpressionmaterialsaninvitrostudy
AT pacurarmariana extraoralthreedimensional3dscanningevaluationofthreedifferentimpressionmaterialsaninvitrostudy
AT zetuirinanicoleta extraoralthreedimensional3dscanningevaluationofthreedifferentimpressionmaterialsaninvitrostudy
AT soporanbiancai extraoralthreedimensional3dscanningevaluationofthreedifferentimpressionmaterialsaninvitrostudy
AT budanamaria extraoralthreedimensional3dscanningevaluationofthreedifferentimpressionmaterialsaninvitrostudy