Cargando…
A Simulation Study to Assess the Factors of Influence on Mean and Median Frequency of sEMG Signals during Muscle Fatigue
Mean and Median frequency are typically used for detecting and monitoring muscle fatigue. These parameters are extracted from power spectral density whose estimate can be obtained by several techniques, each one characterized by advantages and disadvantages. Previous works studied how the implementa...
Autores principales: | , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
MDPI
2022
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9459987/ https://www.ncbi.nlm.nih.gov/pubmed/36080818 http://dx.doi.org/10.3390/s22176360 |
_version_ | 1784786640199221248 |
---|---|
author | Corvini, Giovanni Conforto, Silvia |
author_facet | Corvini, Giovanni Conforto, Silvia |
author_sort | Corvini, Giovanni |
collection | PubMed |
description | Mean and Median frequency are typically used for detecting and monitoring muscle fatigue. These parameters are extracted from power spectral density whose estimate can be obtained by several techniques, each one characterized by advantages and disadvantages. Previous works studied how the implementation settings can influence the performance of these techniques; nevertheless, the estimation results have never been fully evaluated when the power density spectrum is in a low-frequency zone, as happens to the surface electromyography (sEMG) spectrum during muscle fatigue. The latter is therefore the objective of this study that has compared the Welch and the autoregressive parametric approaches on synthetic sEMG signals simulating severe muscle fatigue. Moreover, the sensitivity of both the approaches to the observation duration and to the level of noise has been analyzed. Results showed that the mean frequency greatly depends on the noise level, and that for Signal to Noise Ratio (SNR) less than 10dB the errors make the estimate unacceptable. On the other hand, the error in calculating the median frequency is always in the range 2–10 Hz, so this parameter should be preferred in the tracking of muscle fatigue. Results show that the autoregressive model always outperforms the Welch technique, and that the 3rd order continuously produced accurate and precise estimates; consequently, the latter should be used when analyzing severe fatiguing contraction. |
format | Online Article Text |
id | pubmed-9459987 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2022 |
publisher | MDPI |
record_format | MEDLINE/PubMed |
spelling | pubmed-94599872022-09-10 A Simulation Study to Assess the Factors of Influence on Mean and Median Frequency of sEMG Signals during Muscle Fatigue Corvini, Giovanni Conforto, Silvia Sensors (Basel) Article Mean and Median frequency are typically used for detecting and monitoring muscle fatigue. These parameters are extracted from power spectral density whose estimate can be obtained by several techniques, each one characterized by advantages and disadvantages. Previous works studied how the implementation settings can influence the performance of these techniques; nevertheless, the estimation results have never been fully evaluated when the power density spectrum is in a low-frequency zone, as happens to the surface electromyography (sEMG) spectrum during muscle fatigue. The latter is therefore the objective of this study that has compared the Welch and the autoregressive parametric approaches on synthetic sEMG signals simulating severe muscle fatigue. Moreover, the sensitivity of both the approaches to the observation duration and to the level of noise has been analyzed. Results showed that the mean frequency greatly depends on the noise level, and that for Signal to Noise Ratio (SNR) less than 10dB the errors make the estimate unacceptable. On the other hand, the error in calculating the median frequency is always in the range 2–10 Hz, so this parameter should be preferred in the tracking of muscle fatigue. Results show that the autoregressive model always outperforms the Welch technique, and that the 3rd order continuously produced accurate and precise estimates; consequently, the latter should be used when analyzing severe fatiguing contraction. MDPI 2022-08-24 /pmc/articles/PMC9459987/ /pubmed/36080818 http://dx.doi.org/10.3390/s22176360 Text en © 2022 by the authors. https://creativecommons.org/licenses/by/4.0/Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license (https://creativecommons.org/licenses/by/4.0/). |
spellingShingle | Article Corvini, Giovanni Conforto, Silvia A Simulation Study to Assess the Factors of Influence on Mean and Median Frequency of sEMG Signals during Muscle Fatigue |
title | A Simulation Study to Assess the Factors of Influence on Mean and Median Frequency of sEMG Signals during Muscle Fatigue |
title_full | A Simulation Study to Assess the Factors of Influence on Mean and Median Frequency of sEMG Signals during Muscle Fatigue |
title_fullStr | A Simulation Study to Assess the Factors of Influence on Mean and Median Frequency of sEMG Signals during Muscle Fatigue |
title_full_unstemmed | A Simulation Study to Assess the Factors of Influence on Mean and Median Frequency of sEMG Signals during Muscle Fatigue |
title_short | A Simulation Study to Assess the Factors of Influence on Mean and Median Frequency of sEMG Signals during Muscle Fatigue |
title_sort | simulation study to assess the factors of influence on mean and median frequency of semg signals during muscle fatigue |
topic | Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9459987/ https://www.ncbi.nlm.nih.gov/pubmed/36080818 http://dx.doi.org/10.3390/s22176360 |
work_keys_str_mv | AT corvinigiovanni asimulationstudytoassessthefactorsofinfluenceonmeanandmedianfrequencyofsemgsignalsduringmusclefatigue AT confortosilvia asimulationstudytoassessthefactorsofinfluenceonmeanandmedianfrequencyofsemgsignalsduringmusclefatigue AT corvinigiovanni simulationstudytoassessthefactorsofinfluenceonmeanandmedianfrequencyofsemgsignalsduringmusclefatigue AT confortosilvia simulationstudytoassessthefactorsofinfluenceonmeanandmedianfrequencyofsemgsignalsduringmusclefatigue |