Cargando…

Model-based characterization platform of fiber optic extended-wavelength diffuse reflectance spectroscopy for identification of neurovascular bundles

SIGNIFICANCE: Fiber-optic extended-wavelength diffuse reflectance spectroscopy (EWDRS) using both visible/near-infrared and shortwave-infrared detectors enables improved detection of spectral absorbances arising from lipids, water, and collagen and has demonstrated promise in a variety of applicatio...

Descripción completa

Detalles Bibliográficos
Autores principales: Sun, Yu, Dumont, Alexander P., Arefin, Mohammed Shahriar, Patil, Chetan A.
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Society of Photo-Optical Instrumentation Engineers 2022
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9463544/
https://www.ncbi.nlm.nih.gov/pubmed/36088529
http://dx.doi.org/10.1117/1.JBO.27.9.095002
_version_ 1784787414289481728
author Sun, Yu
Dumont, Alexander P.
Arefin, Mohammed Shahriar
Patil, Chetan A.
author_facet Sun, Yu
Dumont, Alexander P.
Arefin, Mohammed Shahriar
Patil, Chetan A.
author_sort Sun, Yu
collection PubMed
description SIGNIFICANCE: Fiber-optic extended-wavelength diffuse reflectance spectroscopy (EWDRS) using both visible/near-infrared and shortwave-infrared detectors enables improved detection of spectral absorbances arising from lipids, water, and collagen and has demonstrated promise in a variety of applications, including detection of nerves and neurovascular bundles (NVB). Development of future applications of EWDRS for nerve detection could benefit from the use of model-based analyses including Monte Carlo (MC) simulations and evaluation of agreement between model systems and empirical measurements. AIM: The aim of this work is to characterize agreement between EWDRS measurements and simulations and inform future applications of model-based studies of nerve-detecting applications. APPROACH: A model-based platform consisting of an ex vivo microsurgical nerve dissection model, unique two-layer optical phantoms, and MC model simulations of fiber-optic EWDRS spectroscopic measurements were used to characterize EWDRS and compare agreement across models. In addition, MC simulations of an EWDRS measurement scenario are performed to provide a representative example of future analyses. RESULTS: EWDRS studies performed in the common chicken thigh femoral nerve microsurgical dissection model indicate similar spectral features for classification of NVB versus adjacent tissues as reported in porcine models and human subjects. A comparison of measurements from unique EWDRS issue mimicking optical phantoms and MC simulations indicates high agreement between the two in homogeneous and two-layer optical phantoms, as well as in dissected tissues. Finally, MC simulations of measurement over a simulated NVB indicate the potential of future applications for measurement of nerve plexus. CONCLUSIONS: Characterization of agreement between fiber-optic EWDRS measurements and MC simulations demonstrates strong agreement across a variety of tissues and optical phantoms, offering promise for further use to guide the continued development of EWDRS for translational applications.
format Online
Article
Text
id pubmed-9463544
institution National Center for Biotechnology Information
language English
publishDate 2022
publisher Society of Photo-Optical Instrumentation Engineers
record_format MEDLINE/PubMed
spelling pubmed-94635442022-09-14 Model-based characterization platform of fiber optic extended-wavelength diffuse reflectance spectroscopy for identification of neurovascular bundles Sun, Yu Dumont, Alexander P. Arefin, Mohammed Shahriar Patil, Chetan A. J Biomed Opt General SIGNIFICANCE: Fiber-optic extended-wavelength diffuse reflectance spectroscopy (EWDRS) using both visible/near-infrared and shortwave-infrared detectors enables improved detection of spectral absorbances arising from lipids, water, and collagen and has demonstrated promise in a variety of applications, including detection of nerves and neurovascular bundles (NVB). Development of future applications of EWDRS for nerve detection could benefit from the use of model-based analyses including Monte Carlo (MC) simulations and evaluation of agreement between model systems and empirical measurements. AIM: The aim of this work is to characterize agreement between EWDRS measurements and simulations and inform future applications of model-based studies of nerve-detecting applications. APPROACH: A model-based platform consisting of an ex vivo microsurgical nerve dissection model, unique two-layer optical phantoms, and MC model simulations of fiber-optic EWDRS spectroscopic measurements were used to characterize EWDRS and compare agreement across models. In addition, MC simulations of an EWDRS measurement scenario are performed to provide a representative example of future analyses. RESULTS: EWDRS studies performed in the common chicken thigh femoral nerve microsurgical dissection model indicate similar spectral features for classification of NVB versus adjacent tissues as reported in porcine models and human subjects. A comparison of measurements from unique EWDRS issue mimicking optical phantoms and MC simulations indicates high agreement between the two in homogeneous and two-layer optical phantoms, as well as in dissected tissues. Finally, MC simulations of measurement over a simulated NVB indicate the potential of future applications for measurement of nerve plexus. CONCLUSIONS: Characterization of agreement between fiber-optic EWDRS measurements and MC simulations demonstrates strong agreement across a variety of tissues and optical phantoms, offering promise for further use to guide the continued development of EWDRS for translational applications. Society of Photo-Optical Instrumentation Engineers 2022-09-10 2022-09 /pmc/articles/PMC9463544/ /pubmed/36088529 http://dx.doi.org/10.1117/1.JBO.27.9.095002 Text en © 2022 The Authors https://creativecommons.org/licenses/by/4.0/Published by SPIE under a Creative Commons Attribution 4.0 International License. Distribution or reproduction of this work in whole or in part requires full attribution of the original publication, including its DOI.
spellingShingle General
Sun, Yu
Dumont, Alexander P.
Arefin, Mohammed Shahriar
Patil, Chetan A.
Model-based characterization platform of fiber optic extended-wavelength diffuse reflectance spectroscopy for identification of neurovascular bundles
title Model-based characterization platform of fiber optic extended-wavelength diffuse reflectance spectroscopy for identification of neurovascular bundles
title_full Model-based characterization platform of fiber optic extended-wavelength diffuse reflectance spectroscopy for identification of neurovascular bundles
title_fullStr Model-based characterization platform of fiber optic extended-wavelength diffuse reflectance spectroscopy for identification of neurovascular bundles
title_full_unstemmed Model-based characterization platform of fiber optic extended-wavelength diffuse reflectance spectroscopy for identification of neurovascular bundles
title_short Model-based characterization platform of fiber optic extended-wavelength diffuse reflectance spectroscopy for identification of neurovascular bundles
title_sort model-based characterization platform of fiber optic extended-wavelength diffuse reflectance spectroscopy for identification of neurovascular bundles
topic General
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9463544/
https://www.ncbi.nlm.nih.gov/pubmed/36088529
http://dx.doi.org/10.1117/1.JBO.27.9.095002
work_keys_str_mv AT sunyu modelbasedcharacterizationplatformoffiberopticextendedwavelengthdiffusereflectancespectroscopyforidentificationofneurovascularbundles
AT dumontalexanderp modelbasedcharacterizationplatformoffiberopticextendedwavelengthdiffusereflectancespectroscopyforidentificationofneurovascularbundles
AT arefinmohammedshahriar modelbasedcharacterizationplatformoffiberopticextendedwavelengthdiffusereflectancespectroscopyforidentificationofneurovascularbundles
AT patilchetana modelbasedcharacterizationplatformoffiberopticextendedwavelengthdiffusereflectancespectroscopyforidentificationofneurovascularbundles