Cargando…
The clinical outcomes and complications of combined fixation with cannulated screws and the modified Pyrford technique for the treatment of transverse patellar fractures: a case series study
BACKGROUND: Transverse patellar fractures can be fixed using various techniques. The purpose of the current study was to assess the clinical outcomes and complication rate of a combined fixation technique using cannulated screws and the modified Pyrford technique with nonabsorbable polyester sutures...
Autores principales: | , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
BioMed Central
2022
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9463777/ https://www.ncbi.nlm.nih.gov/pubmed/36088315 http://dx.doi.org/10.1186/s12893-022-01788-5 |
_version_ | 1784787460652269568 |
---|---|
author | Li, Yihan Tian, Qingxian Leng, Kunpeng Guo, Meng |
author_facet | Li, Yihan Tian, Qingxian Leng, Kunpeng Guo, Meng |
author_sort | Li, Yihan |
collection | PubMed |
description | BACKGROUND: Transverse patellar fractures can be fixed using various techniques. The purpose of the current study was to assess the clinical outcomes and complication rate of a combined fixation technique using cannulated screws and the modified Pyrford technique with nonabsorbable polyester sutures. METHODS AND PATIENTS: Between January 2015 and February 2021, 26 transverse patellar fractures were fixed with this combined technique. Preoperative data were collected from patients with transverse patellar fractures who were followed up for at least 12 months. At each follow-up visit, plain radiographs were taken. At the 12-month postoperative follow-up, range of motion of the affected knee joint and clinical outcomes, as evaluated by the Bostman scoring system, were recorded. RESULTS: The average Bostman score at the 12-month postoperative follow-up was 28.3 ± 1.5. Furthermore, the average extension and flexion of the knee joint were 1.2 ± 2.1 and 125.6 ± 6.7 degrees, respectively. One patient experienced delayed bone union and one experienced superficial wound infection. There were no other postoperative complications. One patient required removal of the device for social-psychological reasons. CONCLUSIONS: The combined fixation technique with cannulated screws and the modified Pyrford technique with suture materials produced excellent clinical outcomes and a low rate of complications in the treatment of transverse patellar fractures. |
format | Online Article Text |
id | pubmed-9463777 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2022 |
publisher | BioMed Central |
record_format | MEDLINE/PubMed |
spelling | pubmed-94637772022-09-11 The clinical outcomes and complications of combined fixation with cannulated screws and the modified Pyrford technique for the treatment of transverse patellar fractures: a case series study Li, Yihan Tian, Qingxian Leng, Kunpeng Guo, Meng BMC Surg Research BACKGROUND: Transverse patellar fractures can be fixed using various techniques. The purpose of the current study was to assess the clinical outcomes and complication rate of a combined fixation technique using cannulated screws and the modified Pyrford technique with nonabsorbable polyester sutures. METHODS AND PATIENTS: Between January 2015 and February 2021, 26 transverse patellar fractures were fixed with this combined technique. Preoperative data were collected from patients with transverse patellar fractures who were followed up for at least 12 months. At each follow-up visit, plain radiographs were taken. At the 12-month postoperative follow-up, range of motion of the affected knee joint and clinical outcomes, as evaluated by the Bostman scoring system, were recorded. RESULTS: The average Bostman score at the 12-month postoperative follow-up was 28.3 ± 1.5. Furthermore, the average extension and flexion of the knee joint were 1.2 ± 2.1 and 125.6 ± 6.7 degrees, respectively. One patient experienced delayed bone union and one experienced superficial wound infection. There were no other postoperative complications. One patient required removal of the device for social-psychological reasons. CONCLUSIONS: The combined fixation technique with cannulated screws and the modified Pyrford technique with suture materials produced excellent clinical outcomes and a low rate of complications in the treatment of transverse patellar fractures. BioMed Central 2022-09-10 /pmc/articles/PMC9463777/ /pubmed/36088315 http://dx.doi.org/10.1186/s12893-022-01788-5 Text en © The Author(s) 2022 https://creativecommons.org/licenses/by/4.0/Open AccessThis article is licensed under a Creative Commons Attribution 4.0 International License, which permits use, sharing, adaptation, distribution and reproduction in any medium or format, as long as you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons licence, and indicate if changes were made. The images or other third party material in this article are included in the article's Creative Commons licence, unless indicated otherwise in a credit line to the material. If material is not included in the article's Creative Commons licence and your intended use is not permitted by statutory regulation or exceeds the permitted use, you will need to obtain permission directly from the copyright holder. To view a copy of this licence, visit http://creativecommons.org/licenses/by/4.0/ (https://creativecommons.org/licenses/by/4.0/) . The Creative Commons Public Domain Dedication waiver (http://creativecommons.org/publicdomain/zero/1.0/ (https://creativecommons.org/publicdomain/zero/1.0/) ) applies to the data made available in this article, unless otherwise stated in a credit line to the data. |
spellingShingle | Research Li, Yihan Tian, Qingxian Leng, Kunpeng Guo, Meng The clinical outcomes and complications of combined fixation with cannulated screws and the modified Pyrford technique for the treatment of transverse patellar fractures: a case series study |
title | The clinical outcomes and complications of combined fixation with cannulated screws and the modified Pyrford technique for the treatment of transverse patellar fractures: a case series study |
title_full | The clinical outcomes and complications of combined fixation with cannulated screws and the modified Pyrford technique for the treatment of transverse patellar fractures: a case series study |
title_fullStr | The clinical outcomes and complications of combined fixation with cannulated screws and the modified Pyrford technique for the treatment of transverse patellar fractures: a case series study |
title_full_unstemmed | The clinical outcomes and complications of combined fixation with cannulated screws and the modified Pyrford technique for the treatment of transverse patellar fractures: a case series study |
title_short | The clinical outcomes and complications of combined fixation with cannulated screws and the modified Pyrford technique for the treatment of transverse patellar fractures: a case series study |
title_sort | clinical outcomes and complications of combined fixation with cannulated screws and the modified pyrford technique for the treatment of transverse patellar fractures: a case series study |
topic | Research |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9463777/ https://www.ncbi.nlm.nih.gov/pubmed/36088315 http://dx.doi.org/10.1186/s12893-022-01788-5 |
work_keys_str_mv | AT liyihan theclinicaloutcomesandcomplicationsofcombinedfixationwithcannulatedscrewsandthemodifiedpyrfordtechniqueforthetreatmentoftransversepatellarfracturesacaseseriesstudy AT tianqingxian theclinicaloutcomesandcomplicationsofcombinedfixationwithcannulatedscrewsandthemodifiedpyrfordtechniqueforthetreatmentoftransversepatellarfracturesacaseseriesstudy AT lengkunpeng theclinicaloutcomesandcomplicationsofcombinedfixationwithcannulatedscrewsandthemodifiedpyrfordtechniqueforthetreatmentoftransversepatellarfracturesacaseseriesstudy AT guomeng theclinicaloutcomesandcomplicationsofcombinedfixationwithcannulatedscrewsandthemodifiedpyrfordtechniqueforthetreatmentoftransversepatellarfracturesacaseseriesstudy AT liyihan clinicaloutcomesandcomplicationsofcombinedfixationwithcannulatedscrewsandthemodifiedpyrfordtechniqueforthetreatmentoftransversepatellarfracturesacaseseriesstudy AT tianqingxian clinicaloutcomesandcomplicationsofcombinedfixationwithcannulatedscrewsandthemodifiedpyrfordtechniqueforthetreatmentoftransversepatellarfracturesacaseseriesstudy AT lengkunpeng clinicaloutcomesandcomplicationsofcombinedfixationwithcannulatedscrewsandthemodifiedpyrfordtechniqueforthetreatmentoftransversepatellarfracturesacaseseriesstudy AT guomeng clinicaloutcomesandcomplicationsofcombinedfixationwithcannulatedscrewsandthemodifiedpyrfordtechniqueforthetreatmentoftransversepatellarfracturesacaseseriesstudy |