Cargando…

Anterior cruciate ligament autograft maturation on sequential postoperative MRI is not correlated with clinical outcome and anterior knee stability

PURPOSE: Magnetic resonance imaging (MRI) signal intensity is correlated to structural postoperative changes of the anterior cruciate ligament (ACL) autograft. The purpose of this study was to investigate the ACL autograft maturation process via MRI over 2 years postoperatively, compare it to a nati...

Descripción completa

Detalles Bibliográficos
Autores principales: Lutz, Patricia M., Achtnich, Andrea, Schütte, Vincent, Woertler, Klaus, Imhoff, Andreas B., Willinger, Lukas
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Springer Berlin Heidelberg 2021
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9464175/
https://www.ncbi.nlm.nih.gov/pubmed/34739559
http://dx.doi.org/10.1007/s00167-021-06777-4
_version_ 1784787525401837568
author Lutz, Patricia M.
Achtnich, Andrea
Schütte, Vincent
Woertler, Klaus
Imhoff, Andreas B.
Willinger, Lukas
author_facet Lutz, Patricia M.
Achtnich, Andrea
Schütte, Vincent
Woertler, Klaus
Imhoff, Andreas B.
Willinger, Lukas
author_sort Lutz, Patricia M.
collection PubMed
description PURPOSE: Magnetic resonance imaging (MRI) signal intensity is correlated to structural postoperative changes of the anterior cruciate ligament (ACL) autograft. The purpose of this study was to investigate the ACL autograft maturation process via MRI over 2 years postoperatively, compare it to a native ACL signal and correlate the results with clinical outcome, return to preinjury sports levels, and knee laxity measurements. METHODS: ACL autograft signal intensity was measured in 17 male patients (age, 28.3 ± 7.0 years) who underwent ACL reconstruction with hamstring autograft at 6 weeks, 3-, 6-, 12-, and 24 months postoperatively by 3 Tesla MRI. Controls with an intact ACL served as control group (22 males, 8 females; age, 26.7 ± 6.8 years). An ACL/PCL ratio (APR) and ACL/muscle ratio (AMR) was calculated to normalize signals to soft tissue signal. APR and AMR were compared across time and to native ACL signal. Clinical outcome scores (IKDC, Lysholm), return to preinjury sports levels (Tegner activity scale), and knee laxity measurement (KT-1000) were obtained and correlated to APR and AMR at the respective time points. RESULTS: The APR and AMR of the ACL graft changed significantly from the lowest values at 6 weeks to reach the highest intensity after 6 months (p < 0.001). Then, the APR and AMR were significantly different from a native ACL 6 months after surgery (p < 0.01) but approached the APR and AMR of the native ACL at 1- and 2 years after surgery (p < 0.05). The APR changed significantly during the first 2 years postoperatively in the proximal (p < 0.001), mid-substance (p < 0.001), and distal (p < 0.01) intraarticular portion of the ACL autograft. A hypo-intense ACL MRI signal was associated with return to the preinjury sports level (p < 0.05). No correlation was found between ACL MRI graft signal and clinical outcome scores or KT-1000 measurements. CONCLUSION: ACL grafts undergo a continuous maturation process in the first 2 years after surgery. The ACL graft signals became hyper-intense 6 months postoperatively and approximated the signal of a native intact ACL at 12- and 24 months. Patients with a hypo-intense ACL graft signal at 2 years follow-up were more likely to return to preinjury sports levels. The results of the present study provide a template for monitoring the normal ACL maturation process via MRI in case of prolonged clinical symptoms. However, subjective outcome and clinical examination of knee laxity remain important to assess the treatment success and to allow to return to sports. LEVEL OF EVIDENCE: III.
format Online
Article
Text
id pubmed-9464175
institution National Center for Biotechnology Information
language English
publishDate 2021
publisher Springer Berlin Heidelberg
record_format MEDLINE/PubMed
spelling pubmed-94641752022-09-12 Anterior cruciate ligament autograft maturation on sequential postoperative MRI is not correlated with clinical outcome and anterior knee stability Lutz, Patricia M. Achtnich, Andrea Schütte, Vincent Woertler, Klaus Imhoff, Andreas B. Willinger, Lukas Knee Surg Sports Traumatol Arthrosc Knee PURPOSE: Magnetic resonance imaging (MRI) signal intensity is correlated to structural postoperative changes of the anterior cruciate ligament (ACL) autograft. The purpose of this study was to investigate the ACL autograft maturation process via MRI over 2 years postoperatively, compare it to a native ACL signal and correlate the results with clinical outcome, return to preinjury sports levels, and knee laxity measurements. METHODS: ACL autograft signal intensity was measured in 17 male patients (age, 28.3 ± 7.0 years) who underwent ACL reconstruction with hamstring autograft at 6 weeks, 3-, 6-, 12-, and 24 months postoperatively by 3 Tesla MRI. Controls with an intact ACL served as control group (22 males, 8 females; age, 26.7 ± 6.8 years). An ACL/PCL ratio (APR) and ACL/muscle ratio (AMR) was calculated to normalize signals to soft tissue signal. APR and AMR were compared across time and to native ACL signal. Clinical outcome scores (IKDC, Lysholm), return to preinjury sports levels (Tegner activity scale), and knee laxity measurement (KT-1000) were obtained and correlated to APR and AMR at the respective time points. RESULTS: The APR and AMR of the ACL graft changed significantly from the lowest values at 6 weeks to reach the highest intensity after 6 months (p < 0.001). Then, the APR and AMR were significantly different from a native ACL 6 months after surgery (p < 0.01) but approached the APR and AMR of the native ACL at 1- and 2 years after surgery (p < 0.05). The APR changed significantly during the first 2 years postoperatively in the proximal (p < 0.001), mid-substance (p < 0.001), and distal (p < 0.01) intraarticular portion of the ACL autograft. A hypo-intense ACL MRI signal was associated with return to the preinjury sports level (p < 0.05). No correlation was found between ACL MRI graft signal and clinical outcome scores or KT-1000 measurements. CONCLUSION: ACL grafts undergo a continuous maturation process in the first 2 years after surgery. The ACL graft signals became hyper-intense 6 months postoperatively and approximated the signal of a native intact ACL at 12- and 24 months. Patients with a hypo-intense ACL graft signal at 2 years follow-up were more likely to return to preinjury sports levels. The results of the present study provide a template for monitoring the normal ACL maturation process via MRI in case of prolonged clinical symptoms. However, subjective outcome and clinical examination of knee laxity remain important to assess the treatment success and to allow to return to sports. LEVEL OF EVIDENCE: III. Springer Berlin Heidelberg 2021-11-05 2022 /pmc/articles/PMC9464175/ /pubmed/34739559 http://dx.doi.org/10.1007/s00167-021-06777-4 Text en © The Author(s) 2021 https://creativecommons.org/licenses/by/4.0/Open AccessThis article is licensed under a Creative Commons Attribution 4.0 International License, which permits use, sharing, adaptation, distribution and reproduction in any medium or format, as long as you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons licence, and indicate if changes were made. The images or other third party material in this article are included in the article's Creative Commons licence, unless indicated otherwise in a credit line to the material. If material is not included in the article's Creative Commons licence and your intended use is not permitted by statutory regulation or exceeds the permitted use, you will need to obtain permission directly from the copyright holder. To view a copy of this licence, visit http://creativecommons.org/licenses/by/4.0/ (https://creativecommons.org/licenses/by/4.0/) .
spellingShingle Knee
Lutz, Patricia M.
Achtnich, Andrea
Schütte, Vincent
Woertler, Klaus
Imhoff, Andreas B.
Willinger, Lukas
Anterior cruciate ligament autograft maturation on sequential postoperative MRI is not correlated with clinical outcome and anterior knee stability
title Anterior cruciate ligament autograft maturation on sequential postoperative MRI is not correlated with clinical outcome and anterior knee stability
title_full Anterior cruciate ligament autograft maturation on sequential postoperative MRI is not correlated with clinical outcome and anterior knee stability
title_fullStr Anterior cruciate ligament autograft maturation on sequential postoperative MRI is not correlated with clinical outcome and anterior knee stability
title_full_unstemmed Anterior cruciate ligament autograft maturation on sequential postoperative MRI is not correlated with clinical outcome and anterior knee stability
title_short Anterior cruciate ligament autograft maturation on sequential postoperative MRI is not correlated with clinical outcome and anterior knee stability
title_sort anterior cruciate ligament autograft maturation on sequential postoperative mri is not correlated with clinical outcome and anterior knee stability
topic Knee
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9464175/
https://www.ncbi.nlm.nih.gov/pubmed/34739559
http://dx.doi.org/10.1007/s00167-021-06777-4
work_keys_str_mv AT lutzpatriciam anteriorcruciateligamentautograftmaturationonsequentialpostoperativemriisnotcorrelatedwithclinicaloutcomeandanteriorkneestability
AT achtnichandrea anteriorcruciateligamentautograftmaturationonsequentialpostoperativemriisnotcorrelatedwithclinicaloutcomeandanteriorkneestability
AT schuttevincent anteriorcruciateligamentautograftmaturationonsequentialpostoperativemriisnotcorrelatedwithclinicaloutcomeandanteriorkneestability
AT woertlerklaus anteriorcruciateligamentautograftmaturationonsequentialpostoperativemriisnotcorrelatedwithclinicaloutcomeandanteriorkneestability
AT imhoffandreasb anteriorcruciateligamentautograftmaturationonsequentialpostoperativemriisnotcorrelatedwithclinicaloutcomeandanteriorkneestability
AT willingerlukas anteriorcruciateligamentautograftmaturationonsequentialpostoperativemriisnotcorrelatedwithclinicaloutcomeandanteriorkneestability