Validity and Reliability of The Smart Groin Trainer for Measuring Hip Adduction Strength

We analyzed the Smart Groin Trainer device's validity and reliability to measure the isometric hip adduction strength during the adductor squeeze strength test. Fifteen professional soccer players (25.33±4.06 years) and fifteen university students (21.60±1.76 years) participated in this study....

Descripción completa

Detalles Bibliográficos
Autores principales: Carlos Sousa, António, Luís Marques, Diogo, Manuel Calado, António, Pacheco, Carlos, Almeida Marinho, Daniel, Cardoso Marques, Mário, Filipe Travassos, Bruno
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Sciendo 2022
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9465726/
https://www.ncbi.nlm.nih.gov/pubmed/36196353
http://dx.doi.org/10.2478/hukin-2022-0029
_version_ 1784787862102736896
author Carlos Sousa, António
Luís Marques, Diogo
Manuel Calado, António
Pacheco, Carlos
Almeida Marinho, Daniel
Cardoso Marques, Mário
Filipe Travassos, Bruno
author_facet Carlos Sousa, António
Luís Marques, Diogo
Manuel Calado, António
Pacheco, Carlos
Almeida Marinho, Daniel
Cardoso Marques, Mário
Filipe Travassos, Bruno
author_sort Carlos Sousa, António
collection PubMed
description We analyzed the Smart Groin Trainer device's validity and reliability to measure the isometric hip adduction strength during the adductor squeeze strength test. Fifteen professional soccer players (25.33±4.06 years) and fifteen university students (21.60±1.76 years) participated in this study. All participants performed the squeeze strength test using two portable dynamometers: Smart Groin Trainer and Globus Ergometer. Three maximal isometric hip adduction contractions lasting 5s, interspersed by 3min rest intervals, were performed. Reliability was analyzed with intraclass correlation coefficients, standard error of measurements, and minimal detectable change. The absolute percent error and inter-device accuracy were also analyzed. Correlation analysis assessed the inter-device concurrent validity. The results found no significant differences (p>0.05) between devices in the squeeze strength test values in soccer players and university students. Inter-device comparisons revealed excellent levels of reliability and accuracy in soccer players. Concurrent validity measures revealed strong inter-device relationships in soccer players (r=0.89) and very strong relationships in university students (r=0.99). Intra-device analysis using the Smart Groin Trainer showed excellent relative and absolute reliability in tested soccer players. Our data demonstrated excellent levels of agreement between both dynamometers during the squeeze strength test, suggesting the Smart Groin Trainer as a valid, reliable, and accurate device to measure isometric hip adduction strength.
format Online
Article
Text
id pubmed-9465726
institution National Center for Biotechnology Information
language English
publishDate 2022
publisher Sciendo
record_format MEDLINE/PubMed
spelling pubmed-94657262022-10-03 Validity and Reliability of The Smart Groin Trainer for Measuring Hip Adduction Strength Carlos Sousa, António Luís Marques, Diogo Manuel Calado, António Pacheco, Carlos Almeida Marinho, Daniel Cardoso Marques, Mário Filipe Travassos, Bruno J Hum Kinet Section I - Kinesiology We analyzed the Smart Groin Trainer device's validity and reliability to measure the isometric hip adduction strength during the adductor squeeze strength test. Fifteen professional soccer players (25.33±4.06 years) and fifteen university students (21.60±1.76 years) participated in this study. All participants performed the squeeze strength test using two portable dynamometers: Smart Groin Trainer and Globus Ergometer. Three maximal isometric hip adduction contractions lasting 5s, interspersed by 3min rest intervals, were performed. Reliability was analyzed with intraclass correlation coefficients, standard error of measurements, and minimal detectable change. The absolute percent error and inter-device accuracy were also analyzed. Correlation analysis assessed the inter-device concurrent validity. The results found no significant differences (p>0.05) between devices in the squeeze strength test values in soccer players and university students. Inter-device comparisons revealed excellent levels of reliability and accuracy in soccer players. Concurrent validity measures revealed strong inter-device relationships in soccer players (r=0.89) and very strong relationships in university students (r=0.99). Intra-device analysis using the Smart Groin Trainer showed excellent relative and absolute reliability in tested soccer players. Our data demonstrated excellent levels of agreement between both dynamometers during the squeeze strength test, suggesting the Smart Groin Trainer as a valid, reliable, and accurate device to measure isometric hip adduction strength. Sciendo 2022-04-26 /pmc/articles/PMC9465726/ /pubmed/36196353 http://dx.doi.org/10.2478/hukin-2022-0029 Text en © 2022 António Carlos Sousa, Diogo Luís Marques, António Manuel Calado, Carlos Pacheco, Daniel Almeida Marinho, Mário Cardoso Marques, Bruno Filipe Travassos, published by Sciendo https://creativecommons.org/licenses/by-nc-nd/3.0/This work is licensed under the Creative Commons Attribution-NonCommercial-NoDerivatives 3.0 License.
spellingShingle Section I - Kinesiology
Carlos Sousa, António
Luís Marques, Diogo
Manuel Calado, António
Pacheco, Carlos
Almeida Marinho, Daniel
Cardoso Marques, Mário
Filipe Travassos, Bruno
Validity and Reliability of The Smart Groin Trainer for Measuring Hip Adduction Strength
title Validity and Reliability of The Smart Groin Trainer for Measuring Hip Adduction Strength
title_full Validity and Reliability of The Smart Groin Trainer for Measuring Hip Adduction Strength
title_fullStr Validity and Reliability of The Smart Groin Trainer for Measuring Hip Adduction Strength
title_full_unstemmed Validity and Reliability of The Smart Groin Trainer for Measuring Hip Adduction Strength
title_short Validity and Reliability of The Smart Groin Trainer for Measuring Hip Adduction Strength
title_sort validity and reliability of the smart groin trainer for measuring hip adduction strength
topic Section I - Kinesiology
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9465726/
https://www.ncbi.nlm.nih.gov/pubmed/36196353
http://dx.doi.org/10.2478/hukin-2022-0029
work_keys_str_mv AT carlossousaantonio validityandreliabilityofthesmartgrointrainerformeasuringhipadductionstrength
AT luismarquesdiogo validityandreliabilityofthesmartgrointrainerformeasuringhipadductionstrength
AT manuelcaladoantonio validityandreliabilityofthesmartgrointrainerformeasuringhipadductionstrength
AT pachecocarlos validityandreliabilityofthesmartgrointrainerformeasuringhipadductionstrength
AT almeidamarinhodaniel validityandreliabilityofthesmartgrointrainerformeasuringhipadductionstrength
AT cardosomarquesmario validityandreliabilityofthesmartgrointrainerformeasuringhipadductionstrength
AT filipetravassosbruno validityandreliabilityofthesmartgrointrainerformeasuringhipadductionstrength