Cargando…
Dosimetric comparison between VMAT plans using the fast-rotating O-ring linac with dual-layer stacked MLC and helical tomotherapy for nasopharyngeal carcinoma
BACKGROUND: To compare the dosimetric profiles of volumetric modulated arc therapy (VMAT) plans using the fast-rotating O-ring linac (the Halcyon system) based on a dual-layer stacked multi-leaf collimator and helical tomotherapy (HT) for nasopharyngeal cancer (NPCa). METHODS: For 30 NPCa patients,...
Autores principales: | , , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
BioMed Central
2022
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9465858/ https://www.ncbi.nlm.nih.gov/pubmed/36096874 http://dx.doi.org/10.1186/s13014-022-02124-0 |
_version_ | 1784787881382903808 |
---|---|
author | Ju, Sang Gyu Ahn, Yong Chan Kim, Yeong-bi Kim, Jin Man Kwon, Dong Yeol Park, Byoung Suk Yang, Kyungmi |
author_facet | Ju, Sang Gyu Ahn, Yong Chan Kim, Yeong-bi Kim, Jin Man Kwon, Dong Yeol Park, Byoung Suk Yang, Kyungmi |
author_sort | Ju, Sang Gyu |
collection | PubMed |
description | BACKGROUND: To compare the dosimetric profiles of volumetric modulated arc therapy (VMAT) plans using the fast-rotating O-ring linac (the Halcyon system) based on a dual-layer stacked multi-leaf collimator and helical tomotherapy (HT) for nasopharyngeal cancer (NPCa). METHODS: For 30 NPCa patients, three sets of RT plans were generated, under the same policy of contouring and dose constraints: HT plan; Halcyon VMAT plan with two arcs (HL(2arc)); and Halcyon VMAT plan with four arcs (HL(4arc)), respectively. The intended dose schedule was to deliver 67.2 Gy to the planning gross target volume (P-GTV) and 56.0 Gy to the planning clinical target volume (P-CTV) in 28 fractions using the simultaneously integrated boost concept. Target volumes and organ at risks dose metrics were evaluated for all plans. Normal tissue complication probabilities (NTCP) for esophagus, parotid glands, spinal cord, and brain stem were compared. RESULTS: The HT plan achieved the best dose homogeneity index for both P_GTV and P_CTV, followed by the HL(4arc) and L(2arc) plans. No significant difference in the dose conformity index (CI) for P_GTV was observed between the HT plan (0.80) and either the HL(2arc) plan (0.79) or the HL(4arc) plan (0.83). The HL(4arc) plan showed the best CI for P_CTV (0.88), followed by the HL(2arc) plan (0.83) and the HT plan (0.80). The HL(4arc) plan (median, interquartile rage (Q1, Q3): 25.36 (22.22, 26.89) Gy) showed the lowest D(mean) in the parotid glands, followed by the HT (25.88 (23.87, 27.87) Gy) and HL(2arc) plans (28.00 (23.24, 33.99) Gy). In the oral cavity (OC) dose comparison, the HT (22.03 (19.79, 24.85) Gy) plan showed the lowest D(mean) compared to the HL(2arc) (23.96 (20.84, 28.02) Gy) and HL(4arc) (24.14 (20.17, 27.53) Gy) plans. Intermediate and low dose regions (40–65% of the prescribed dose) were well fit to the target volume in HL(4arc), compared to the HT and HL(2arc) plans. All plans met the dose constraints for the other OARs with sufficient dose margins. The between-group differences in the median NTCP values for the parotid glands and OC were < 3.47% and < 1.7% points, respectively. CONCLUSIONS: The dosimetric profiles of Halcyon VMAT plans were comparable to that of HT, and HL(4arc) showed better dosimetric profiles than HL(2arc) for NPCa. SUPPLEMENTARY INFORMATION: The online version contains supplementary material available at 10.1186/s13014-022-02124-0. |
format | Online Article Text |
id | pubmed-9465858 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2022 |
publisher | BioMed Central |
record_format | MEDLINE/PubMed |
spelling | pubmed-94658582022-09-13 Dosimetric comparison between VMAT plans using the fast-rotating O-ring linac with dual-layer stacked MLC and helical tomotherapy for nasopharyngeal carcinoma Ju, Sang Gyu Ahn, Yong Chan Kim, Yeong-bi Kim, Jin Man Kwon, Dong Yeol Park, Byoung Suk Yang, Kyungmi Radiat Oncol Research BACKGROUND: To compare the dosimetric profiles of volumetric modulated arc therapy (VMAT) plans using the fast-rotating O-ring linac (the Halcyon system) based on a dual-layer stacked multi-leaf collimator and helical tomotherapy (HT) for nasopharyngeal cancer (NPCa). METHODS: For 30 NPCa patients, three sets of RT plans were generated, under the same policy of contouring and dose constraints: HT plan; Halcyon VMAT plan with two arcs (HL(2arc)); and Halcyon VMAT plan with four arcs (HL(4arc)), respectively. The intended dose schedule was to deliver 67.2 Gy to the planning gross target volume (P-GTV) and 56.0 Gy to the planning clinical target volume (P-CTV) in 28 fractions using the simultaneously integrated boost concept. Target volumes and organ at risks dose metrics were evaluated for all plans. Normal tissue complication probabilities (NTCP) for esophagus, parotid glands, spinal cord, and brain stem were compared. RESULTS: The HT plan achieved the best dose homogeneity index for both P_GTV and P_CTV, followed by the HL(4arc) and L(2arc) plans. No significant difference in the dose conformity index (CI) for P_GTV was observed between the HT plan (0.80) and either the HL(2arc) plan (0.79) or the HL(4arc) plan (0.83). The HL(4arc) plan showed the best CI for P_CTV (0.88), followed by the HL(2arc) plan (0.83) and the HT plan (0.80). The HL(4arc) plan (median, interquartile rage (Q1, Q3): 25.36 (22.22, 26.89) Gy) showed the lowest D(mean) in the parotid glands, followed by the HT (25.88 (23.87, 27.87) Gy) and HL(2arc) plans (28.00 (23.24, 33.99) Gy). In the oral cavity (OC) dose comparison, the HT (22.03 (19.79, 24.85) Gy) plan showed the lowest D(mean) compared to the HL(2arc) (23.96 (20.84, 28.02) Gy) and HL(4arc) (24.14 (20.17, 27.53) Gy) plans. Intermediate and low dose regions (40–65% of the prescribed dose) were well fit to the target volume in HL(4arc), compared to the HT and HL(2arc) plans. All plans met the dose constraints for the other OARs with sufficient dose margins. The between-group differences in the median NTCP values for the parotid glands and OC were < 3.47% and < 1.7% points, respectively. CONCLUSIONS: The dosimetric profiles of Halcyon VMAT plans were comparable to that of HT, and HL(4arc) showed better dosimetric profiles than HL(2arc) for NPCa. SUPPLEMENTARY INFORMATION: The online version contains supplementary material available at 10.1186/s13014-022-02124-0. BioMed Central 2022-09-12 /pmc/articles/PMC9465858/ /pubmed/36096874 http://dx.doi.org/10.1186/s13014-022-02124-0 Text en © The Author(s) 2022 https://creativecommons.org/licenses/by/4.0/Open AccessThis article is licensed under a Creative Commons Attribution 4.0 International License, which permits use, sharing, adaptation, distribution and reproduction in any medium or format, as long as you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons licence, and indicate if changes were made. The images or other third party material in this article are included in the article's Creative Commons licence, unless indicated otherwise in a credit line to the material. If material is not included in the article's Creative Commons licence and your intended use is not permitted by statutory regulation or exceeds the permitted use, you will need to obtain permission directly from the copyright holder. To view a copy of this licence, visit http://creativecommons.org/licenses/by/4.0/ (https://creativecommons.org/licenses/by/4.0/) . The Creative Commons Public Domain Dedication waiver (http://creativecommons.org/publicdomain/zero/1.0/ (https://creativecommons.org/publicdomain/zero/1.0/) ) applies to the data made available in this article, unless otherwise stated in a credit line to the data. |
spellingShingle | Research Ju, Sang Gyu Ahn, Yong Chan Kim, Yeong-bi Kim, Jin Man Kwon, Dong Yeol Park, Byoung Suk Yang, Kyungmi Dosimetric comparison between VMAT plans using the fast-rotating O-ring linac with dual-layer stacked MLC and helical tomotherapy for nasopharyngeal carcinoma |
title | Dosimetric comparison between VMAT plans using the fast-rotating O-ring linac with dual-layer stacked MLC and helical tomotherapy for nasopharyngeal carcinoma |
title_full | Dosimetric comparison between VMAT plans using the fast-rotating O-ring linac with dual-layer stacked MLC and helical tomotherapy for nasopharyngeal carcinoma |
title_fullStr | Dosimetric comparison between VMAT plans using the fast-rotating O-ring linac with dual-layer stacked MLC and helical tomotherapy for nasopharyngeal carcinoma |
title_full_unstemmed | Dosimetric comparison between VMAT plans using the fast-rotating O-ring linac with dual-layer stacked MLC and helical tomotherapy for nasopharyngeal carcinoma |
title_short | Dosimetric comparison between VMAT plans using the fast-rotating O-ring linac with dual-layer stacked MLC and helical tomotherapy for nasopharyngeal carcinoma |
title_sort | dosimetric comparison between vmat plans using the fast-rotating o-ring linac with dual-layer stacked mlc and helical tomotherapy for nasopharyngeal carcinoma |
topic | Research |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9465858/ https://www.ncbi.nlm.nih.gov/pubmed/36096874 http://dx.doi.org/10.1186/s13014-022-02124-0 |
work_keys_str_mv | AT jusanggyu dosimetriccomparisonbetweenvmatplansusingthefastrotatingoringlinacwithduallayerstackedmlcandhelicaltomotherapyfornasopharyngealcarcinoma AT ahnyongchan dosimetriccomparisonbetweenvmatplansusingthefastrotatingoringlinacwithduallayerstackedmlcandhelicaltomotherapyfornasopharyngealcarcinoma AT kimyeongbi dosimetriccomparisonbetweenvmatplansusingthefastrotatingoringlinacwithduallayerstackedmlcandhelicaltomotherapyfornasopharyngealcarcinoma AT kimjinman dosimetriccomparisonbetweenvmatplansusingthefastrotatingoringlinacwithduallayerstackedmlcandhelicaltomotherapyfornasopharyngealcarcinoma AT kwondongyeol dosimetriccomparisonbetweenvmatplansusingthefastrotatingoringlinacwithduallayerstackedmlcandhelicaltomotherapyfornasopharyngealcarcinoma AT parkbyoungsuk dosimetriccomparisonbetweenvmatplansusingthefastrotatingoringlinacwithduallayerstackedmlcandhelicaltomotherapyfornasopharyngealcarcinoma AT yangkyungmi dosimetriccomparisonbetweenvmatplansusingthefastrotatingoringlinacwithduallayerstackedmlcandhelicaltomotherapyfornasopharyngealcarcinoma |