Cargando…
A blood-based miRNA signature for early non-invasive diagnosis of preeclampsia
BACKGROUND: Preeclampsia (PE) is a multisystemic maternal syndrome with substantial maternal and fetal morbidity and mortality. Currently, there is no clinically viable non-invasive biomarker assay for early detection, thus limiting the effective prevention and therapeutic strategies for PE. METHODS...
Autores principales: | , , , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
BioMed Central
2022
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9469544/ https://www.ncbi.nlm.nih.gov/pubmed/36096786 http://dx.doi.org/10.1186/s12916-022-02495-x |
Sumario: | BACKGROUND: Preeclampsia (PE) is a multisystemic maternal syndrome with substantial maternal and fetal morbidity and mortality. Currently, there is no clinically viable non-invasive biomarker assay for early detection, thus limiting the effective prevention and therapeutic strategies for PE. METHODS: We conducted a discovery–training–validation three-phase retrospective and prospective study with cross-platform and multicenter cohorts. The initial biomarkers were discovered and verified in tissue specimens by small RNA sequencing and qRT-PCR. A miRNA signature (miR2PE-score) was developed using Firth’s bias-reduced logistic regression analysis and subsequently validated in two independent multinational retrospective cohorts and two prospective plasma cohorts. RESULTS: We initially identified five PE-associated differentially expressed miRNAs from miRNA sequencing data and subsequently validated two miRNAs (miR-196b-5p and miR-584-5p) as robust biomarkers by association analysis with clinical characteristics and qRT-PCR in tissue specimens in the discovery phase. Using Firth’s bias-reduced logistic regression analysis, we developed the miR2PE-score for the early detection of PE. The miR2PE-score showed a high diagnostic performance with an area under the receiver operating characteristic curve (AUROC) of 0.920, 0.848, 0.864, and 0.812 in training, internal, and two external validation cross-platform and multicenter cohorts, respectively. Finally, we demonstrated the non-invasive diagnostic performance of the miR2PE-score in two prospective plasma cohorts with AUROC of 0.933 and 0.787. Furthermore, the miR2PE-score revealed superior performance in non-invasive diagnosis compared with previously published miRNA biomarkers. CONCLUSIONS: We developed and validated a novel and robust blood-based miRNA signature, which may serve as a promising clinically applicable non-invasive tool for the early detection of PE. GRAPHICAL ABSTRACT: [Image: see text] SUPPLEMENTARY INFORMATION: The online version contains supplementary material available at 10.1186/s12916-022-02495-x. |
---|