Cargando…

Duplex Hemodynamic Parameters of Both Superior and Inferior Thyroid Arteries in Evaluation of Thyroid Hyperfunction Disorders

BACKGROUND: Thyrotoxicosis may be caused by Graves’ disease or destructive thyroiditis. Differentiation between causes of thyrotoxicosis is crucial as management will differ. (99m)Technetium (Tc)-pertechnetate thyroid scintigraphy is currently the gold standard for this purpose, however, is expensiv...

Descripción completa

Detalles Bibliográficos
Autores principales: Assem Hussein, Maha, Abdel Hamid, Alaa, M Abdel Samie, Rasha, Hussein, Elshaymaa, Sadik Elsawy, Shereen
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Dove 2022
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9470082/
https://www.ncbi.nlm.nih.gov/pubmed/36110917
http://dx.doi.org/10.2147/IJGM.S375016
_version_ 1784788774874513408
author Assem Hussein, Maha
Abdel Hamid, Alaa
M Abdel Samie, Rasha
Hussein, Elshaymaa
Sadik Elsawy, Shereen
author_facet Assem Hussein, Maha
Abdel Hamid, Alaa
M Abdel Samie, Rasha
Hussein, Elshaymaa
Sadik Elsawy, Shereen
author_sort Assem Hussein, Maha
collection PubMed
description BACKGROUND: Thyrotoxicosis may be caused by Graves’ disease or destructive thyroiditis. Differentiation between causes of thyrotoxicosis is crucial as management will differ. (99m)Technetium (Tc)-pertechnetate thyroid scintigraphy is currently the gold standard for this purpose, however, is expensive and uses ionizing radiation. OBJECTIVE: To evaluate the role of color flow Doppler Ultrasound (CDU) of the superior thyroid (STA) and inferior thyroid arteries (ITA) as an inexpensive, non-invasive tool that can aid in differentiating between Graves’ disease and thyroiditis and compare it with thyroid scintigraphy. METHODS: Sixty-nine patients with newly-diagnosed thyrotoxicosis and 30 controls were enrolled. Thyroid functions, thyroid scintigraphy, and CDU of STA and ITA with measurements of peak systolic velocity (PSV) and end diastolic velocity (EDV), were performed. According to thyroid scintigraphy results, patients were divided into two groups: 42 patients with Graves’ disease and 27 patients with thyroiditis. RESULTS: PSV and EDV of both STA and ITA were significantly higher in patients with Graves’ disease than thyroiditis (p-values <0.001). The STA-PSV had an equal sensitivity and specificity of 66.7%; cut-off value 76.57 cm/s, while those of STA-EDV were 73.8%, and 77.8% respectively; cut-off value 28.22 cm/s. ITA-PSV had a sensitivity and specificity of 76.2% and 77.8%, respectively; cut-off value 62.12 cm/s), while those of ITA-EDV were 78.6% and 77.8%, respectively; cut-off value 5.22 cm/s. CONCLUSION: CDU parameters of the STA and ITA could be used as an alternative to thyroid scintigraphy for discriminating between Graves’ disease and thyroiditis.
format Online
Article
Text
id pubmed-9470082
institution National Center for Biotechnology Information
language English
publishDate 2022
publisher Dove
record_format MEDLINE/PubMed
spelling pubmed-94700822022-09-14 Duplex Hemodynamic Parameters of Both Superior and Inferior Thyroid Arteries in Evaluation of Thyroid Hyperfunction Disorders Assem Hussein, Maha Abdel Hamid, Alaa M Abdel Samie, Rasha Hussein, Elshaymaa Sadik Elsawy, Shereen Int J Gen Med Original Research BACKGROUND: Thyrotoxicosis may be caused by Graves’ disease or destructive thyroiditis. Differentiation between causes of thyrotoxicosis is crucial as management will differ. (99m)Technetium (Tc)-pertechnetate thyroid scintigraphy is currently the gold standard for this purpose, however, is expensive and uses ionizing radiation. OBJECTIVE: To evaluate the role of color flow Doppler Ultrasound (CDU) of the superior thyroid (STA) and inferior thyroid arteries (ITA) as an inexpensive, non-invasive tool that can aid in differentiating between Graves’ disease and thyroiditis and compare it with thyroid scintigraphy. METHODS: Sixty-nine patients with newly-diagnosed thyrotoxicosis and 30 controls were enrolled. Thyroid functions, thyroid scintigraphy, and CDU of STA and ITA with measurements of peak systolic velocity (PSV) and end diastolic velocity (EDV), were performed. According to thyroid scintigraphy results, patients were divided into two groups: 42 patients with Graves’ disease and 27 patients with thyroiditis. RESULTS: PSV and EDV of both STA and ITA were significantly higher in patients with Graves’ disease than thyroiditis (p-values <0.001). The STA-PSV had an equal sensitivity and specificity of 66.7%; cut-off value 76.57 cm/s, while those of STA-EDV were 73.8%, and 77.8% respectively; cut-off value 28.22 cm/s. ITA-PSV had a sensitivity and specificity of 76.2% and 77.8%, respectively; cut-off value 62.12 cm/s), while those of ITA-EDV were 78.6% and 77.8%, respectively; cut-off value 5.22 cm/s. CONCLUSION: CDU parameters of the STA and ITA could be used as an alternative to thyroid scintigraphy for discriminating between Graves’ disease and thyroiditis. Dove 2022-09-09 /pmc/articles/PMC9470082/ /pubmed/36110917 http://dx.doi.org/10.2147/IJGM.S375016 Text en © 2022 Assem Hussein et al. https://creativecommons.org/licenses/by-nc/3.0/This work is published and licensed by Dove Medical Press Limited. The full terms of this license are available at https://www.dovepress.com/terms.php and incorporate the Creative Commons Attribution – Non Commercial (unported, v3.0) License (http://creativecommons.org/licenses/by-nc/3.0/ (https://creativecommons.org/licenses/by-nc/3.0/) ). By accessing the work you hereby accept the Terms. Non-commercial uses of the work are permitted without any further permission from Dove Medical Press Limited, provided the work is properly attributed. For permission for commercial use of this work, please see paragraphs 4.2 and 5 of our Terms (https://www.dovepress.com/terms.php).
spellingShingle Original Research
Assem Hussein, Maha
Abdel Hamid, Alaa
M Abdel Samie, Rasha
Hussein, Elshaymaa
Sadik Elsawy, Shereen
Duplex Hemodynamic Parameters of Both Superior and Inferior Thyroid Arteries in Evaluation of Thyroid Hyperfunction Disorders
title Duplex Hemodynamic Parameters of Both Superior and Inferior Thyroid Arteries in Evaluation of Thyroid Hyperfunction Disorders
title_full Duplex Hemodynamic Parameters of Both Superior and Inferior Thyroid Arteries in Evaluation of Thyroid Hyperfunction Disorders
title_fullStr Duplex Hemodynamic Parameters of Both Superior and Inferior Thyroid Arteries in Evaluation of Thyroid Hyperfunction Disorders
title_full_unstemmed Duplex Hemodynamic Parameters of Both Superior and Inferior Thyroid Arteries in Evaluation of Thyroid Hyperfunction Disorders
title_short Duplex Hemodynamic Parameters of Both Superior and Inferior Thyroid Arteries in Evaluation of Thyroid Hyperfunction Disorders
title_sort duplex hemodynamic parameters of both superior and inferior thyroid arteries in evaluation of thyroid hyperfunction disorders
topic Original Research
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9470082/
https://www.ncbi.nlm.nih.gov/pubmed/36110917
http://dx.doi.org/10.2147/IJGM.S375016
work_keys_str_mv AT assemhusseinmaha duplexhemodynamicparametersofbothsuperiorandinferiorthyroidarteriesinevaluationofthyroidhyperfunctiondisorders
AT abdelhamidalaa duplexhemodynamicparametersofbothsuperiorandinferiorthyroidarteriesinevaluationofthyroidhyperfunctiondisorders
AT mabdelsamierasha duplexhemodynamicparametersofbothsuperiorandinferiorthyroidarteriesinevaluationofthyroidhyperfunctiondisorders
AT husseinelshaymaa duplexhemodynamicparametersofbothsuperiorandinferiorthyroidarteriesinevaluationofthyroidhyperfunctiondisorders
AT sadikelsawyshereen duplexhemodynamicparametersofbothsuperiorandinferiorthyroidarteriesinevaluationofthyroidhyperfunctiondisorders