Computational Intelligence Powered Experimental Test on Energy Consumption Characteristics of Cold-Water Phase-Change Energy Heat Pump System
In order to study the influence on the effective energy efficiency ratio, the energy consumption characteristics of a cold-water phase change heat pump system are discussed in this article. An experimental system of the cold-water phase-change energy heat pump system is designed and constructed, and...
Autores principales: | , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Hindawi
2022
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9470346/ https://www.ncbi.nlm.nih.gov/pubmed/36110910 http://dx.doi.org/10.1155/2022/1941855 |
_version_ | 1784788821717549056 |
---|---|
author | Wu, Ronghua Yu, Hao Xu, Ying |
author_facet | Wu, Ronghua Yu, Hao Xu, Ying |
author_sort | Wu, Ronghua |
collection | PubMed |
description | In order to study the influence on the effective energy efficiency ratio, the energy consumption characteristics of a cold-water phase change heat pump system are discussed in this article. An experimental system of the cold-water phase-change energy heat pump system is designed and constructed, and then the deicing energy consumption and unit energy consumption of the heat pump system are analyzed by computational intelligence-powered methods. At last, the primary energy utilization ratio of the heat pump system is calculated. The results show that under the setting conditions, the deicing capacity of the heat pump system is about 0.135, the primary energy utilization ratio is about 1.145, and the COP (coefficient of performance) of the heat pump unit is between 2.8 and 3.2. Considering the system's deicing energy consumption, the effective COP of the unit is between 2.42 and 2.76, so from this point, this kind of heat pump system can be widely used in the future. In order to improve the effective COP of the unit, the processes of ice making and melting should be further optimized to reduce heat loss and power loss. |
format | Online Article Text |
id | pubmed-9470346 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2022 |
publisher | Hindawi |
record_format | MEDLINE/PubMed |
spelling | pubmed-94703462022-09-14 Computational Intelligence Powered Experimental Test on Energy Consumption Characteristics of Cold-Water Phase-Change Energy Heat Pump System Wu, Ronghua Yu, Hao Xu, Ying Comput Intell Neurosci Research Article In order to study the influence on the effective energy efficiency ratio, the energy consumption characteristics of a cold-water phase change heat pump system are discussed in this article. An experimental system of the cold-water phase-change energy heat pump system is designed and constructed, and then the deicing energy consumption and unit energy consumption of the heat pump system are analyzed by computational intelligence-powered methods. At last, the primary energy utilization ratio of the heat pump system is calculated. The results show that under the setting conditions, the deicing capacity of the heat pump system is about 0.135, the primary energy utilization ratio is about 1.145, and the COP (coefficient of performance) of the heat pump unit is between 2.8 and 3.2. Considering the system's deicing energy consumption, the effective COP of the unit is between 2.42 and 2.76, so from this point, this kind of heat pump system can be widely used in the future. In order to improve the effective COP of the unit, the processes of ice making and melting should be further optimized to reduce heat loss and power loss. Hindawi 2022-09-06 /pmc/articles/PMC9470346/ /pubmed/36110910 http://dx.doi.org/10.1155/2022/1941855 Text en Copyright © 2022 Ronghua Wu et al. https://creativecommons.org/licenses/by/4.0/This is an open access article distributed under the Creative Commons Attribution License, which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited. |
spellingShingle | Research Article Wu, Ronghua Yu, Hao Xu, Ying Computational Intelligence Powered Experimental Test on Energy Consumption Characteristics of Cold-Water Phase-Change Energy Heat Pump System |
title | Computational Intelligence Powered Experimental Test on Energy Consumption Characteristics of Cold-Water Phase-Change Energy Heat Pump System |
title_full | Computational Intelligence Powered Experimental Test on Energy Consumption Characteristics of Cold-Water Phase-Change Energy Heat Pump System |
title_fullStr | Computational Intelligence Powered Experimental Test on Energy Consumption Characteristics of Cold-Water Phase-Change Energy Heat Pump System |
title_full_unstemmed | Computational Intelligence Powered Experimental Test on Energy Consumption Characteristics of Cold-Water Phase-Change Energy Heat Pump System |
title_short | Computational Intelligence Powered Experimental Test on Energy Consumption Characteristics of Cold-Water Phase-Change Energy Heat Pump System |
title_sort | computational intelligence powered experimental test on energy consumption characteristics of cold-water phase-change energy heat pump system |
topic | Research Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9470346/ https://www.ncbi.nlm.nih.gov/pubmed/36110910 http://dx.doi.org/10.1155/2022/1941855 |
work_keys_str_mv | AT wuronghua computationalintelligencepoweredexperimentaltestonenergyconsumptioncharacteristicsofcoldwaterphasechangeenergyheatpumpsystem AT yuhao computationalintelligencepoweredexperimentaltestonenergyconsumptioncharacteristicsofcoldwaterphasechangeenergyheatpumpsystem AT xuying computationalintelligencepoweredexperimentaltestonenergyconsumptioncharacteristicsofcoldwaterphasechangeenergyheatpumpsystem |