Manual versus Mechanical Delivery of High-Quality Cardiopulmonary Resuscitation on a River-Based Fire Rescue Boat

OBJECTIVES: Studies have demonstrated the efficacy of mechanical devices at delivering high-quality cardiopulmonary resuscitation (HQ-CPR) in various transport settings. Herein, this study investigates the efficacy of manual and mechanical HQ-CPR delivery on a fire rescue boat. METHODS: A total of 1...

Descripción completa

Detalles Bibliográficos
Autores principales: Manoukian, Martin A.C., Tancredi, Daniel J., Linvill, Matthew T., Wynia, Elisabeth H., Beaver, Brianna, Rose, John S., Mumma, Bryn E.
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Cambridge University Press 2022
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9470525/
https://www.ncbi.nlm.nih.gov/pubmed/35875994
http://dx.doi.org/10.1017/S1049023X22001042
_version_ 1784788865172635648
author Manoukian, Martin A.C.
Tancredi, Daniel J.
Linvill, Matthew T.
Wynia, Elisabeth H.
Beaver, Brianna
Rose, John S.
Mumma, Bryn E.
author_facet Manoukian, Martin A.C.
Tancredi, Daniel J.
Linvill, Matthew T.
Wynia, Elisabeth H.
Beaver, Brianna
Rose, John S.
Mumma, Bryn E.
author_sort Manoukian, Martin A.C.
collection PubMed
description OBJECTIVES: Studies have demonstrated the efficacy of mechanical devices at delivering high-quality cardiopulmonary resuscitation (HQ-CPR) in various transport settings. Herein, this study investigates the efficacy of manual and mechanical HQ-CPR delivery on a fire rescue boat. METHODS: A total of 15 active firefighter-paramedics were recruited for a prospective manikin-based trial. Each paramedic performed two minutes manual compression-only CPR while navigating on a river-based fire rescue boat. The boat was piloted in either a stable linear manner or dynamic S-turn manner to simulate obstacle avoidance. For each session of manual HQ-CPR, a session of mechanical HQ-CPR was also performed with a LUCAS 3 (Stryker; Kalamazoo, Michigan USA). A total of 60 sessions were completed. Parameters recorded included compression fraction (CF) and the percentage of compressions with correct depth >5cm (D%), correct rate 100-120 (R%), full release (FR%), and correct hand position (HP%). A composite HQ-CPR score was calculated as follows: ((D% + R% + FR% + HP%)/4) * CF%). Differences in magnitude of change seen in stable versus dynamic navigation within study conditions were evaluated with a Z-score calculation. Difficulty of HQ-CPR delivery was assessed utilizing the Borg Rating of Perceived Exertion Scale. RESULTS: Participants were mostly male and had a median experience of 20 years. Manual HQ-CPR delivered during stable navigation out-performed manual HQ-CPR delivered during dynamic navigation for composite score and trended towards superiority for FR% and R%. There was no difference seen for any measured variable when comparing mechanical HQ-CPR delivered during stable navigation versus dynamic navigation. Mechanical HQ-CPR out-performed manual HQ-CPR during both stable and dynamic navigation in terms of composite score, FR%, and R%. Z-score calculation demonstrated that manual HQ-CPR delivery was significantly more affected by drive style than mechanical HQ-CPR delivery in terms of composite HQ-CPR score and trended towards significance for FR% and R%. Borg Rating of Perceived Exertion was higher for manual CPR delivered during dynamic sessions than for stable sessions. CONCLUSION: Mechanical HQ-CPR delivery is superior to manual HQ-CPR delivery during both stable and dynamic riverine navigation. Whereas manual HQ-CPR delivery was worse during dynamic transportation conditions compared to stable transport conditions, mechanical HQ-CPR delivery was unaffected by drive style. This suggests the utility of routine use of mechanical HQ-CPR devices in the riverine patient transport setting.
format Online
Article
Text
id pubmed-9470525
institution National Center for Biotechnology Information
language English
publishDate 2022
publisher Cambridge University Press
record_format MEDLINE/PubMed
spelling pubmed-94705252022-09-26 Manual versus Mechanical Delivery of High-Quality Cardiopulmonary Resuscitation on a River-Based Fire Rescue Boat Manoukian, Martin A.C. Tancredi, Daniel J. Linvill, Matthew T. Wynia, Elisabeth H. Beaver, Brianna Rose, John S. Mumma, Bryn E. Prehosp Disaster Med Original Research OBJECTIVES: Studies have demonstrated the efficacy of mechanical devices at delivering high-quality cardiopulmonary resuscitation (HQ-CPR) in various transport settings. Herein, this study investigates the efficacy of manual and mechanical HQ-CPR delivery on a fire rescue boat. METHODS: A total of 15 active firefighter-paramedics were recruited for a prospective manikin-based trial. Each paramedic performed two minutes manual compression-only CPR while navigating on a river-based fire rescue boat. The boat was piloted in either a stable linear manner or dynamic S-turn manner to simulate obstacle avoidance. For each session of manual HQ-CPR, a session of mechanical HQ-CPR was also performed with a LUCAS 3 (Stryker; Kalamazoo, Michigan USA). A total of 60 sessions were completed. Parameters recorded included compression fraction (CF) and the percentage of compressions with correct depth >5cm (D%), correct rate 100-120 (R%), full release (FR%), and correct hand position (HP%). A composite HQ-CPR score was calculated as follows: ((D% + R% + FR% + HP%)/4) * CF%). Differences in magnitude of change seen in stable versus dynamic navigation within study conditions were evaluated with a Z-score calculation. Difficulty of HQ-CPR delivery was assessed utilizing the Borg Rating of Perceived Exertion Scale. RESULTS: Participants were mostly male and had a median experience of 20 years. Manual HQ-CPR delivered during stable navigation out-performed manual HQ-CPR delivered during dynamic navigation for composite score and trended towards superiority for FR% and R%. There was no difference seen for any measured variable when comparing mechanical HQ-CPR delivered during stable navigation versus dynamic navigation. Mechanical HQ-CPR out-performed manual HQ-CPR during both stable and dynamic navigation in terms of composite score, FR%, and R%. Z-score calculation demonstrated that manual HQ-CPR delivery was significantly more affected by drive style than mechanical HQ-CPR delivery in terms of composite HQ-CPR score and trended towards significance for FR% and R%. Borg Rating of Perceived Exertion was higher for manual CPR delivered during dynamic sessions than for stable sessions. CONCLUSION: Mechanical HQ-CPR delivery is superior to manual HQ-CPR delivery during both stable and dynamic riverine navigation. Whereas manual HQ-CPR delivery was worse during dynamic transportation conditions compared to stable transport conditions, mechanical HQ-CPR delivery was unaffected by drive style. This suggests the utility of routine use of mechanical HQ-CPR devices in the riverine patient transport setting. Cambridge University Press 2022-10 2022-07-25 /pmc/articles/PMC9470525/ /pubmed/35875994 http://dx.doi.org/10.1017/S1049023X22001042 Text en © The Author(s) 2022 https://creativecommons.org/licenses/by/4.0/This is an Open Access article, distributed under the terms of the Creative Commons Attribution licence (https://creativecommons.org/licenses/by/4.0/), which permits unrestricted re-use, distribution, and reproduction in any medium, provided the original work is properly cited.
spellingShingle Original Research
Manoukian, Martin A.C.
Tancredi, Daniel J.
Linvill, Matthew T.
Wynia, Elisabeth H.
Beaver, Brianna
Rose, John S.
Mumma, Bryn E.
Manual versus Mechanical Delivery of High-Quality Cardiopulmonary Resuscitation on a River-Based Fire Rescue Boat
title Manual versus Mechanical Delivery of High-Quality Cardiopulmonary Resuscitation on a River-Based Fire Rescue Boat
title_full Manual versus Mechanical Delivery of High-Quality Cardiopulmonary Resuscitation on a River-Based Fire Rescue Boat
title_fullStr Manual versus Mechanical Delivery of High-Quality Cardiopulmonary Resuscitation on a River-Based Fire Rescue Boat
title_full_unstemmed Manual versus Mechanical Delivery of High-Quality Cardiopulmonary Resuscitation on a River-Based Fire Rescue Boat
title_short Manual versus Mechanical Delivery of High-Quality Cardiopulmonary Resuscitation on a River-Based Fire Rescue Boat
title_sort manual versus mechanical delivery of high-quality cardiopulmonary resuscitation on a river-based fire rescue boat
topic Original Research
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9470525/
https://www.ncbi.nlm.nih.gov/pubmed/35875994
http://dx.doi.org/10.1017/S1049023X22001042
work_keys_str_mv AT manoukianmartinac manualversusmechanicaldeliveryofhighqualitycardiopulmonaryresuscitationonariverbasedfirerescueboat
AT tancredidanielj manualversusmechanicaldeliveryofhighqualitycardiopulmonaryresuscitationonariverbasedfirerescueboat
AT linvillmatthewt manualversusmechanicaldeliveryofhighqualitycardiopulmonaryresuscitationonariverbasedfirerescueboat
AT wyniaelisabethh manualversusmechanicaldeliveryofhighqualitycardiopulmonaryresuscitationonariverbasedfirerescueboat
AT beaverbrianna manualversusmechanicaldeliveryofhighqualitycardiopulmonaryresuscitationonariverbasedfirerescueboat
AT rosejohns manualversusmechanicaldeliveryofhighqualitycardiopulmonaryresuscitationonariverbasedfirerescueboat
AT mummabryne manualversusmechanicaldeliveryofhighqualitycardiopulmonaryresuscitationonariverbasedfirerescueboat