Cargando…
Defining new reference intervals for serum free light chains in individuals with chronic kidney disease: Results of the iStopMM study
Serum free light chain (FLC) concentration is greatly affected by kidney function. Using a large prospective population-based cohort, we aimed to establish a reference interval for FLCs in persons with chronic kidney disease (CKD). A total of 75422 participants of the iStopMM study were screened wit...
Autores principales: | , , , , , , , , , , , , , , , , , , , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Nature Publishing Group UK
2022
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9470548/ https://www.ncbi.nlm.nih.gov/pubmed/36100605 http://dx.doi.org/10.1038/s41408-022-00732-3 |
_version_ | 1784788870277103616 |
---|---|
author | Long, Thorir Einarsson Indridason, Olafur Skuli Palsson, Runolfur Rognvaldsson, Sæmundur Love, Thorvardur Jon Thorsteinsdottir, Sigrun Sverrisdottir, Ingigerdur Solveig Vidarsson, Brynjar Onundarson, Pall Torfi Agnarsson, Bjarni Agnar Sigurdardottir, Margret Thorsteinsdottir, Ingunn Olafsson, Isleifur Thordardottir, Asdis Rosa Eythorsson, Elias Jonsson, Asbjorn Gislason, Gauti Olafsson, Andri Steingrimsdottir, Hlif Hultcrantz, Malin Durie, Brian G. M. Harding, Stephen Landgren, Ola Kristinsson, Sigurdur Yngvi |
author_facet | Long, Thorir Einarsson Indridason, Olafur Skuli Palsson, Runolfur Rognvaldsson, Sæmundur Love, Thorvardur Jon Thorsteinsdottir, Sigrun Sverrisdottir, Ingigerdur Solveig Vidarsson, Brynjar Onundarson, Pall Torfi Agnarsson, Bjarni Agnar Sigurdardottir, Margret Thorsteinsdottir, Ingunn Olafsson, Isleifur Thordardottir, Asdis Rosa Eythorsson, Elias Jonsson, Asbjorn Gislason, Gauti Olafsson, Andri Steingrimsdottir, Hlif Hultcrantz, Malin Durie, Brian G. M. Harding, Stephen Landgren, Ola Kristinsson, Sigurdur Yngvi |
author_sort | Long, Thorir Einarsson |
collection | PubMed |
description | Serum free light chain (FLC) concentration is greatly affected by kidney function. Using a large prospective population-based cohort, we aimed to establish a reference interval for FLCs in persons with chronic kidney disease (CKD). A total of 75422 participants of the iStopMM study were screened with serum FLC, serum protein electrophoresis and immunofixation. Estimated glomerular filtration rate (eGFR) was calculated from serum creatinine. Central 99% reference intervals were determined, and 95% confidence intervals calculated. Included were 6461 (12%) participants with measured FLCs, eGFR < 60 mL/min/1.73 m(2), not receiving renal replacement therapy, and without evidence of monoclonality. Using current reference intervals, 60% and 21% had kappa and lambda FLC values outside the normal range. The FLC ratio was outside standard reference interval (0.26–1.65) in 9% of participants and outside current kidney reference interval (0.37–3.10) in 0.7%. New reference intervals for FLC and FLC ratio were established. New reference intervals for the FLC ratio were 0.46–2.62, 0.48–3.38, and 0.54–3.30 for eGFR 45–59, 30–44, and < 30 mL/min/1.73 m(2) groups, respectively. The crude prevalence of LC-MGUS in CKD patients was 0.5%. We conclude that current reference intervals for FLC and FLC ratio are inaccurate in CKD patients and propose new eGFR based reference intervals to be implemented. |
format | Online Article Text |
id | pubmed-9470548 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2022 |
publisher | Nature Publishing Group UK |
record_format | MEDLINE/PubMed |
spelling | pubmed-94705482022-09-15 Defining new reference intervals for serum free light chains in individuals with chronic kidney disease: Results of the iStopMM study Long, Thorir Einarsson Indridason, Olafur Skuli Palsson, Runolfur Rognvaldsson, Sæmundur Love, Thorvardur Jon Thorsteinsdottir, Sigrun Sverrisdottir, Ingigerdur Solveig Vidarsson, Brynjar Onundarson, Pall Torfi Agnarsson, Bjarni Agnar Sigurdardottir, Margret Thorsteinsdottir, Ingunn Olafsson, Isleifur Thordardottir, Asdis Rosa Eythorsson, Elias Jonsson, Asbjorn Gislason, Gauti Olafsson, Andri Steingrimsdottir, Hlif Hultcrantz, Malin Durie, Brian G. M. Harding, Stephen Landgren, Ola Kristinsson, Sigurdur Yngvi Blood Cancer J Article Serum free light chain (FLC) concentration is greatly affected by kidney function. Using a large prospective population-based cohort, we aimed to establish a reference interval for FLCs in persons with chronic kidney disease (CKD). A total of 75422 participants of the iStopMM study were screened with serum FLC, serum protein electrophoresis and immunofixation. Estimated glomerular filtration rate (eGFR) was calculated from serum creatinine. Central 99% reference intervals were determined, and 95% confidence intervals calculated. Included were 6461 (12%) participants with measured FLCs, eGFR < 60 mL/min/1.73 m(2), not receiving renal replacement therapy, and without evidence of monoclonality. Using current reference intervals, 60% and 21% had kappa and lambda FLC values outside the normal range. The FLC ratio was outside standard reference interval (0.26–1.65) in 9% of participants and outside current kidney reference interval (0.37–3.10) in 0.7%. New reference intervals for FLC and FLC ratio were established. New reference intervals for the FLC ratio were 0.46–2.62, 0.48–3.38, and 0.54–3.30 for eGFR 45–59, 30–44, and < 30 mL/min/1.73 m(2) groups, respectively. The crude prevalence of LC-MGUS in CKD patients was 0.5%. We conclude that current reference intervals for FLC and FLC ratio are inaccurate in CKD patients and propose new eGFR based reference intervals to be implemented. Nature Publishing Group UK 2022-09-14 /pmc/articles/PMC9470548/ /pubmed/36100605 http://dx.doi.org/10.1038/s41408-022-00732-3 Text en © The Author(s) 2022 https://creativecommons.org/licenses/by/4.0/Open Access This article is licensed under a Creative Commons Attribution 4.0 International License, which permits use, sharing, adaptation, distribution and reproduction in any medium or format, as long as you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons license, and indicate if changes were made. The images or other third party material in this article are included in the article’s Creative Commons license, unless indicated otherwise in a credit line to the material. If material is not included in the article’s Creative Commons license and your intended use is not permitted by statutory regulation or exceeds the permitted use, you will need to obtain permission directly from the copyright holder. To view a copy of this license, visit http://creativecommons.org/licenses/by/4.0/ (https://creativecommons.org/licenses/by/4.0/) . |
spellingShingle | Article Long, Thorir Einarsson Indridason, Olafur Skuli Palsson, Runolfur Rognvaldsson, Sæmundur Love, Thorvardur Jon Thorsteinsdottir, Sigrun Sverrisdottir, Ingigerdur Solveig Vidarsson, Brynjar Onundarson, Pall Torfi Agnarsson, Bjarni Agnar Sigurdardottir, Margret Thorsteinsdottir, Ingunn Olafsson, Isleifur Thordardottir, Asdis Rosa Eythorsson, Elias Jonsson, Asbjorn Gislason, Gauti Olafsson, Andri Steingrimsdottir, Hlif Hultcrantz, Malin Durie, Brian G. M. Harding, Stephen Landgren, Ola Kristinsson, Sigurdur Yngvi Defining new reference intervals for serum free light chains in individuals with chronic kidney disease: Results of the iStopMM study |
title | Defining new reference intervals for serum free light chains in individuals with chronic kidney disease: Results of the iStopMM study |
title_full | Defining new reference intervals for serum free light chains in individuals with chronic kidney disease: Results of the iStopMM study |
title_fullStr | Defining new reference intervals for serum free light chains in individuals with chronic kidney disease: Results of the iStopMM study |
title_full_unstemmed | Defining new reference intervals for serum free light chains in individuals with chronic kidney disease: Results of the iStopMM study |
title_short | Defining new reference intervals for serum free light chains in individuals with chronic kidney disease: Results of the iStopMM study |
title_sort | defining new reference intervals for serum free light chains in individuals with chronic kidney disease: results of the istopmm study |
topic | Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9470548/ https://www.ncbi.nlm.nih.gov/pubmed/36100605 http://dx.doi.org/10.1038/s41408-022-00732-3 |
work_keys_str_mv | AT longthorireinarsson definingnewreferenceintervalsforserumfreelightchainsinindividualswithchronickidneydiseaseresultsoftheistopmmstudy AT indridasonolafurskuli definingnewreferenceintervalsforserumfreelightchainsinindividualswithchronickidneydiseaseresultsoftheistopmmstudy AT palssonrunolfur definingnewreferenceintervalsforserumfreelightchainsinindividualswithchronickidneydiseaseresultsoftheistopmmstudy AT rognvaldssonsæmundur definingnewreferenceintervalsforserumfreelightchainsinindividualswithchronickidneydiseaseresultsoftheistopmmstudy AT lovethorvardurjon definingnewreferenceintervalsforserumfreelightchainsinindividualswithchronickidneydiseaseresultsoftheistopmmstudy AT thorsteinsdottirsigrun definingnewreferenceintervalsforserumfreelightchainsinindividualswithchronickidneydiseaseresultsoftheistopmmstudy AT sverrisdottiringigerdursolveig definingnewreferenceintervalsforserumfreelightchainsinindividualswithchronickidneydiseaseresultsoftheistopmmstudy AT vidarssonbrynjar definingnewreferenceintervalsforserumfreelightchainsinindividualswithchronickidneydiseaseresultsoftheistopmmstudy AT onundarsonpalltorfi definingnewreferenceintervalsforserumfreelightchainsinindividualswithchronickidneydiseaseresultsoftheistopmmstudy AT agnarssonbjarniagnar definingnewreferenceintervalsforserumfreelightchainsinindividualswithchronickidneydiseaseresultsoftheistopmmstudy AT sigurdardottirmargret definingnewreferenceintervalsforserumfreelightchainsinindividualswithchronickidneydiseaseresultsoftheistopmmstudy AT thorsteinsdottiringunn definingnewreferenceintervalsforserumfreelightchainsinindividualswithchronickidneydiseaseresultsoftheistopmmstudy AT olafssonisleifur definingnewreferenceintervalsforserumfreelightchainsinindividualswithchronickidneydiseaseresultsoftheistopmmstudy AT thordardottirasdisrosa definingnewreferenceintervalsforserumfreelightchainsinindividualswithchronickidneydiseaseresultsoftheistopmmstudy AT eythorssonelias definingnewreferenceintervalsforserumfreelightchainsinindividualswithchronickidneydiseaseresultsoftheistopmmstudy AT jonssonasbjorn definingnewreferenceintervalsforserumfreelightchainsinindividualswithchronickidneydiseaseresultsoftheistopmmstudy AT gislasongauti definingnewreferenceintervalsforserumfreelightchainsinindividualswithchronickidneydiseaseresultsoftheistopmmstudy AT olafssonandri definingnewreferenceintervalsforserumfreelightchainsinindividualswithchronickidneydiseaseresultsoftheistopmmstudy AT steingrimsdottirhlif definingnewreferenceintervalsforserumfreelightchainsinindividualswithchronickidneydiseaseresultsoftheistopmmstudy AT hultcrantzmalin definingnewreferenceintervalsforserumfreelightchainsinindividualswithchronickidneydiseaseresultsoftheistopmmstudy AT duriebriangm definingnewreferenceintervalsforserumfreelightchainsinindividualswithchronickidneydiseaseresultsoftheistopmmstudy AT hardingstephen definingnewreferenceintervalsforserumfreelightchainsinindividualswithchronickidneydiseaseresultsoftheistopmmstudy AT landgrenola definingnewreferenceintervalsforserumfreelightchainsinindividualswithchronickidneydiseaseresultsoftheistopmmstudy AT kristinssonsigurduryngvi definingnewreferenceintervalsforserumfreelightchainsinindividualswithchronickidneydiseaseresultsoftheistopmmstudy |