Cargando…

Is Internal Rotation Measurement of the Hip Useful for Ruling in Cam or Pincer Morphology in Asymptomatic Males? A Diagnostic Accuracy Study

BACKGROUND: Cam and pincer morphologies are associated with limited internal rotation. However, the routine clinical examination for hip rotation has limited reliability. A more standardized method of measuring hip rotation might increase test-retest and interobserver reliability and might be useful...

Descripción completa

Detalles Bibliográficos
Autores principales: Hilfiker, Roger, Hunkeler, Marc, Limacher, Andreas, Leunig, Michael, Bonel, Harald, Egger, Matthias, Jüni, Peter, Reichenbach, Stephan
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Wolters Kluwer 2022
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9473784/
https://www.ncbi.nlm.nih.gov/pubmed/35700433
http://dx.doi.org/10.1097/CORR.0000000000002244
_version_ 1784789572037640192
author Hilfiker, Roger
Hunkeler, Marc
Limacher, Andreas
Leunig, Michael
Bonel, Harald
Egger, Matthias
Jüni, Peter
Reichenbach, Stephan
author_facet Hilfiker, Roger
Hunkeler, Marc
Limacher, Andreas
Leunig, Michael
Bonel, Harald
Egger, Matthias
Jüni, Peter
Reichenbach, Stephan
author_sort Hilfiker, Roger
collection PubMed
description BACKGROUND: Cam and pincer morphologies are associated with limited internal rotation. However, the routine clinical examination for hip rotation has limited reliability. A more standardized method of measuring hip rotation might increase test-retest and interobserver reliability and might be useful as a screening test to detect different hip morphologies without the need for imaging. We developed an examination chair to standardize the measurement of internal hip rotation, which improved interobserver reliability. However, the diagnostic test accuracy for this test is unknown. QUESTION/PURPOSE: Is a standardized method of determining internal hip rotation using an examination chair useful in detecting cam and pincer morphology with MRI as a reference standard? METHODS: A diagnostic test accuracy study was conducted in a sample of asymptomatic males. Using an examination chair with a standardized seated position, internal rotation was measured in 1080 men aged 18 to 21 years who had been conscripted for the Swiss army. The chair prevents compensatory movement by stabilizing the pelvis and the thighs with belts. The force to produce the internal rotation was standardized with a pulley system. Previous results showed that the measurements with the examination chair are similar to clinical assessment but with higher interobserver agreement. A random sample of 430 asymptomatic males was invited to undergo hip MRI. Of those, 244 White European males responded to the invitation and had a mean age of 20 ± 0.7 years and a mean internal rotation of the hip of 33° ± 8.5°. Using MRI as the reference standard, 69% (169 of 244) had a normal hip, 24% (59 of 244) a definite cam morphology (Grades 2 and 3), 3% (8 of 244) an increased acetabular depth, and 3% (8 of 244) a combination of both. One experienced radiologist graded cam morphology as follows: 0 = normal, 1 = mild, 2 = moderate, and 3 = severe. Pincer morphology was defined by increased acetabular depth (≤ 3 mm distance between the center of the femoral neck and the line connecting the anterior and posterior acetabular rims). The intraobserver agreement was substantial (weighted κ of 0.65). A receiver operating characteristic (ROC) curve was fitted, and sensitivity, specificity, and likelihood ratios were estimated for different internal rotation cutoffs. RESULTS: For cam morphology, the area under the ROC curve was 0.75 (95% CI 0.67 to 0.82). Internal hip rotation of less than 20° yielded a positive likelihood ratio of 9.57 (sensitivity 0.13, specificity 0.99), and a value of 40° or more resulted in a negative likelihood ratio of 0.36 (sensitivity 0.93, specificity 0.20). The area under the curve for detecting the combination of cam and pincer morphologies was 0.87 (95% CI 0.74 to 1.0). A cutoff of 20° yielded a positive likelihood ratio of 9.03 (sensitivity 0.33, specificity 0.96). CONCLUSION: This examination chair showed moderate-to-good diagnostic value to rule in hip cam morphology in White European males. However, at the extremes of the 95% confidence intervals, diagnostic performance would be poor. Nonetheless, we believe this test can contribute to identifying cam morphologies, and we hope that future, larger studies—ideally in more diverse patient populations—will seek to validate this to arrive at more precise estimates of the diagnostic performance of this test. LEVEL OF EVIDENCE: Level III, diagnostic study.
format Online
Article
Text
id pubmed-9473784
institution National Center for Biotechnology Information
language English
publishDate 2022
publisher Wolters Kluwer
record_format MEDLINE/PubMed
spelling pubmed-94737842023-10-01 Is Internal Rotation Measurement of the Hip Useful for Ruling in Cam or Pincer Morphology in Asymptomatic Males? A Diagnostic Accuracy Study Hilfiker, Roger Hunkeler, Marc Limacher, Andreas Leunig, Michael Bonel, Harald Egger, Matthias Jüni, Peter Reichenbach, Stephan Clin Orthop Relat Res Clinical Research BACKGROUND: Cam and pincer morphologies are associated with limited internal rotation. However, the routine clinical examination for hip rotation has limited reliability. A more standardized method of measuring hip rotation might increase test-retest and interobserver reliability and might be useful as a screening test to detect different hip morphologies without the need for imaging. We developed an examination chair to standardize the measurement of internal hip rotation, which improved interobserver reliability. However, the diagnostic test accuracy for this test is unknown. QUESTION/PURPOSE: Is a standardized method of determining internal hip rotation using an examination chair useful in detecting cam and pincer morphology with MRI as a reference standard? METHODS: A diagnostic test accuracy study was conducted in a sample of asymptomatic males. Using an examination chair with a standardized seated position, internal rotation was measured in 1080 men aged 18 to 21 years who had been conscripted for the Swiss army. The chair prevents compensatory movement by stabilizing the pelvis and the thighs with belts. The force to produce the internal rotation was standardized with a pulley system. Previous results showed that the measurements with the examination chair are similar to clinical assessment but with higher interobserver agreement. A random sample of 430 asymptomatic males was invited to undergo hip MRI. Of those, 244 White European males responded to the invitation and had a mean age of 20 ± 0.7 years and a mean internal rotation of the hip of 33° ± 8.5°. Using MRI as the reference standard, 69% (169 of 244) had a normal hip, 24% (59 of 244) a definite cam morphology (Grades 2 and 3), 3% (8 of 244) an increased acetabular depth, and 3% (8 of 244) a combination of both. One experienced radiologist graded cam morphology as follows: 0 = normal, 1 = mild, 2 = moderate, and 3 = severe. Pincer morphology was defined by increased acetabular depth (≤ 3 mm distance between the center of the femoral neck and the line connecting the anterior and posterior acetabular rims). The intraobserver agreement was substantial (weighted κ of 0.65). A receiver operating characteristic (ROC) curve was fitted, and sensitivity, specificity, and likelihood ratios were estimated for different internal rotation cutoffs. RESULTS: For cam morphology, the area under the ROC curve was 0.75 (95% CI 0.67 to 0.82). Internal hip rotation of less than 20° yielded a positive likelihood ratio of 9.57 (sensitivity 0.13, specificity 0.99), and a value of 40° or more resulted in a negative likelihood ratio of 0.36 (sensitivity 0.93, specificity 0.20). The area under the curve for detecting the combination of cam and pincer morphologies was 0.87 (95% CI 0.74 to 1.0). A cutoff of 20° yielded a positive likelihood ratio of 9.03 (sensitivity 0.33, specificity 0.96). CONCLUSION: This examination chair showed moderate-to-good diagnostic value to rule in hip cam morphology in White European males. However, at the extremes of the 95% confidence intervals, diagnostic performance would be poor. Nonetheless, we believe this test can contribute to identifying cam morphologies, and we hope that future, larger studies—ideally in more diverse patient populations—will seek to validate this to arrive at more precise estimates of the diagnostic performance of this test. LEVEL OF EVIDENCE: Level III, diagnostic study. Wolters Kluwer 2022-10 2022-06-13 /pmc/articles/PMC9473784/ /pubmed/35700433 http://dx.doi.org/10.1097/CORR.0000000000002244 Text en Copyright © 2022 The Author(s). Published by Wolters Kluwer Health, Inc. on behalf of the Association of Bone and Joint Surgeons https://creativecommons.org/licenses/by-nc-nd/4.0/This is an open-access article distributed under the terms of the Creative Commons Attribution-Non Commercial-No Derivatives License 4.0 (CCBY-NC-ND) (https://creativecommons.org/licenses/by-nc-nd/4.0/) , where it is permissible to download and share the work provided it is properly cited. The work cannot be changed in any way or used commercially without permission from the journal.
spellingShingle Clinical Research
Hilfiker, Roger
Hunkeler, Marc
Limacher, Andreas
Leunig, Michael
Bonel, Harald
Egger, Matthias
Jüni, Peter
Reichenbach, Stephan
Is Internal Rotation Measurement of the Hip Useful for Ruling in Cam or Pincer Morphology in Asymptomatic Males? A Diagnostic Accuracy Study
title Is Internal Rotation Measurement of the Hip Useful for Ruling in Cam or Pincer Morphology in Asymptomatic Males? A Diagnostic Accuracy Study
title_full Is Internal Rotation Measurement of the Hip Useful for Ruling in Cam or Pincer Morphology in Asymptomatic Males? A Diagnostic Accuracy Study
title_fullStr Is Internal Rotation Measurement of the Hip Useful for Ruling in Cam or Pincer Morphology in Asymptomatic Males? A Diagnostic Accuracy Study
title_full_unstemmed Is Internal Rotation Measurement of the Hip Useful for Ruling in Cam or Pincer Morphology in Asymptomatic Males? A Diagnostic Accuracy Study
title_short Is Internal Rotation Measurement of the Hip Useful for Ruling in Cam or Pincer Morphology in Asymptomatic Males? A Diagnostic Accuracy Study
title_sort is internal rotation measurement of the hip useful for ruling in cam or pincer morphology in asymptomatic males? a diagnostic accuracy study
topic Clinical Research
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9473784/
https://www.ncbi.nlm.nih.gov/pubmed/35700433
http://dx.doi.org/10.1097/CORR.0000000000002244
work_keys_str_mv AT hilfikerroger isinternalrotationmeasurementofthehipusefulforrulingincamorpincermorphologyinasymptomaticmalesadiagnosticaccuracystudy
AT hunkelermarc isinternalrotationmeasurementofthehipusefulforrulingincamorpincermorphologyinasymptomaticmalesadiagnosticaccuracystudy
AT limacherandreas isinternalrotationmeasurementofthehipusefulforrulingincamorpincermorphologyinasymptomaticmalesadiagnosticaccuracystudy
AT leunigmichael isinternalrotationmeasurementofthehipusefulforrulingincamorpincermorphologyinasymptomaticmalesadiagnosticaccuracystudy
AT bonelharald isinternalrotationmeasurementofthehipusefulforrulingincamorpincermorphologyinasymptomaticmalesadiagnosticaccuracystudy
AT eggermatthias isinternalrotationmeasurementofthehipusefulforrulingincamorpincermorphologyinasymptomaticmalesadiagnosticaccuracystudy
AT junipeter isinternalrotationmeasurementofthehipusefulforrulingincamorpincermorphologyinasymptomaticmalesadiagnosticaccuracystudy
AT reichenbachstephan isinternalrotationmeasurementofthehipusefulforrulingincamorpincermorphologyinasymptomaticmalesadiagnosticaccuracystudy