Cargando…

Feasibility of Metal Artifact Reduction on CT Angiography for Planning Direct Surgery of Tentorial dAVF after Onyx Embolization

Although Onyx is approved as an embolic material for arteriovenous malformation (AVM) and dural arteriovenous fistula (dAVF), metal artifacts due to Onyx on CT remain problematic. We report the feasibility of a metal artifact reduction (MAR) algorithm on CT angiography (CTA) in the planning of direc...

Descripción completa

Detalles Bibliográficos
Autores principales: Nakagawa, Kanji, Toyota, Shingo, Shimizu, Takeshi, Murakami, Tomoaki, Taki, Takuyu
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Thieme Medical and Scientific Publishers Pvt. Ltd. 2022
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9473860/
https://www.ncbi.nlm.nih.gov/pubmed/36120632
http://dx.doi.org/10.1055/s-0042-1750386
_version_ 1784789588793884672
author Nakagawa, Kanji
Toyota, Shingo
Shimizu, Takeshi
Murakami, Tomoaki
Taki, Takuyu
author_facet Nakagawa, Kanji
Toyota, Shingo
Shimizu, Takeshi
Murakami, Tomoaki
Taki, Takuyu
author_sort Nakagawa, Kanji
collection PubMed
description Although Onyx is approved as an embolic material for arteriovenous malformation (AVM) and dural arteriovenous fistula (dAVF), metal artifacts due to Onyx on CT remain problematic. We report the feasibility of a metal artifact reduction (MAR) algorithm on CT angiography (CTA) in the planning of direct surgery of dAVF after transarterial Onyx embolization. A 45-year-old male patient presented with right pulsatile tinnitus, and cerebral angiography demonstrated right tentorial dAVF. As the dAVF had not completely disappeared even after Onyx transarterial embolization, we planned direct surgery. Evaluation of the lesion was difficult on normal preoperative CTA because of Onyx artifacts, but CTA using MAR enabled a detailed planning of direct surgery. Direct surgery was performed through right retrosigmoid craniotomy. Referencing CTA using MAR, we identified the draining veins originating from the main drainer, which were coagulated and cut, achieving complete occlusion of the dAVF. His symptoms disappeared with no postoperative complications. CT angiography using MAR was useful for planning direct surgery after Onyx embolization. As the incidence of direct surgery after transarterial Onyx embolization for AVM or dAVF is increasing, MAR on CTA will become more important.
format Online
Article
Text
id pubmed-9473860
institution National Center for Biotechnology Information
language English
publishDate 2022
publisher Thieme Medical and Scientific Publishers Pvt. Ltd.
record_format MEDLINE/PubMed
spelling pubmed-94738602022-09-15 Feasibility of Metal Artifact Reduction on CT Angiography for Planning Direct Surgery of Tentorial dAVF after Onyx Embolization Nakagawa, Kanji Toyota, Shingo Shimizu, Takeshi Murakami, Tomoaki Taki, Takuyu Asian J Neurosurg Although Onyx is approved as an embolic material for arteriovenous malformation (AVM) and dural arteriovenous fistula (dAVF), metal artifacts due to Onyx on CT remain problematic. We report the feasibility of a metal artifact reduction (MAR) algorithm on CT angiography (CTA) in the planning of direct surgery of dAVF after transarterial Onyx embolization. A 45-year-old male patient presented with right pulsatile tinnitus, and cerebral angiography demonstrated right tentorial dAVF. As the dAVF had not completely disappeared even after Onyx transarterial embolization, we planned direct surgery. Evaluation of the lesion was difficult on normal preoperative CTA because of Onyx artifacts, but CTA using MAR enabled a detailed planning of direct surgery. Direct surgery was performed through right retrosigmoid craniotomy. Referencing CTA using MAR, we identified the draining veins originating from the main drainer, which were coagulated and cut, achieving complete occlusion of the dAVF. His symptoms disappeared with no postoperative complications. CT angiography using MAR was useful for planning direct surgery after Onyx embolization. As the incidence of direct surgery after transarterial Onyx embolization for AVM or dAVF is increasing, MAR on CTA will become more important. Thieme Medical and Scientific Publishers Pvt. Ltd. 2022-08-25 /pmc/articles/PMC9473860/ /pubmed/36120632 http://dx.doi.org/10.1055/s-0042-1750386 Text en Asian Congress of Neurological Surgeons. This is an open access article published by Thieme under the terms of the Creative Commons Attribution-NonDerivative-NonCommercial License, permitting copying and reproduction so long as the original work is given appropriate credit. Contents may not be used for commercial purposes, or adapted, remixed, transformed or built upon. ( https://creativecommons.org/licenses/by-nc-nd/4.0/ ) https://creativecommons.org/licenses/by-nc-nd/4.0/This is an open-access article distributed under the terms of the Creative Commons Attribution-NonCommercial-NoDerivatives License, which permits unrestricted reproduction and distribution, for non-commercial purposes only; and use and reproduction, but not distribution, of adapted material for non-commercial purposes only, provided the original work is properly cited.
spellingShingle Nakagawa, Kanji
Toyota, Shingo
Shimizu, Takeshi
Murakami, Tomoaki
Taki, Takuyu
Feasibility of Metal Artifact Reduction on CT Angiography for Planning Direct Surgery of Tentorial dAVF after Onyx Embolization
title Feasibility of Metal Artifact Reduction on CT Angiography for Planning Direct Surgery of Tentorial dAVF after Onyx Embolization
title_full Feasibility of Metal Artifact Reduction on CT Angiography for Planning Direct Surgery of Tentorial dAVF after Onyx Embolization
title_fullStr Feasibility of Metal Artifact Reduction on CT Angiography for Planning Direct Surgery of Tentorial dAVF after Onyx Embolization
title_full_unstemmed Feasibility of Metal Artifact Reduction on CT Angiography for Planning Direct Surgery of Tentorial dAVF after Onyx Embolization
title_short Feasibility of Metal Artifact Reduction on CT Angiography for Planning Direct Surgery of Tentorial dAVF after Onyx Embolization
title_sort feasibility of metal artifact reduction on ct angiography for planning direct surgery of tentorial davf after onyx embolization
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9473860/
https://www.ncbi.nlm.nih.gov/pubmed/36120632
http://dx.doi.org/10.1055/s-0042-1750386
work_keys_str_mv AT nakagawakanji feasibilityofmetalartifactreductiononctangiographyforplanningdirectsurgeryoftentorialdavfafteronyxembolization
AT toyotashingo feasibilityofmetalartifactreductiononctangiographyforplanningdirectsurgeryoftentorialdavfafteronyxembolization
AT shimizutakeshi feasibilityofmetalartifactreductiononctangiographyforplanningdirectsurgeryoftentorialdavfafteronyxembolization
AT murakamitomoaki feasibilityofmetalartifactreductiononctangiographyforplanningdirectsurgeryoftentorialdavfafteronyxembolization
AT takitakuyu feasibilityofmetalartifactreductiononctangiographyforplanningdirectsurgeryoftentorialdavfafteronyxembolization